155 related articles for article (PubMed ID: 36368912)
1. Tier-based formalism for safety assessment of custom-built radio-frequency transmit coils.
Steensma BR; Sadeghi-Tarakameh A; Meliadò EF; van den Berg CAT; Klomp DWJ; Luijten PR; Metzger GJ; Eryaman Y; Raaijmakers AJE
NMR Biomed; 2023 May; 36(5):e4874. PubMed ID: 36368912
[TBL] [Abstract][Full Text] [Related]
2. Improved
Schmidt S; Ertürk MA; He X; Haluptzok T; Eryaman Y; Metzger GJ
Magn Reson Med; 2024 Feb; 91(2):513-529. PubMed ID: 37705412
[TBL] [Abstract][Full Text] [Related]
3. RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits.
Fiedler TM; Ladd ME; Bitz AK
Med Phys; 2017 Jan; 44(1):143-157. PubMed ID: 28102957
[TBL] [Abstract][Full Text] [Related]
4. Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.
Meliadò EF; van den Berg CAT; Luijten PR; Raaijmakers AJE
Magn Reson Med; 2019 Mar; 81(3):2106-2119. PubMed ID: 30414210
[TBL] [Abstract][Full Text] [Related]
5. Actual patient position versus safety models: Specific Absorption Rate implications of initial head position for Ultrahigh Field Magnetic Resonance Imaging.
Kopanoglu E
NMR Biomed; 2023 May; 36(5):e4876. PubMed ID: 36385447
[TBL] [Abstract][Full Text] [Related]
6. Simulation-based evaluation of SAR and flip angle homogeneity for five transmit head arrays at 14 T.
Harrevelt SD; Roos THM; Klomp DWJ; Steensma BR; Raaijmakers AJE
MAGMA; 2023 Apr; 36(2):245-255. PubMed ID: 37000320
[TBL] [Abstract][Full Text] [Related]
7. Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T-10.5 T.
Kazemivalipour E; Sadeghi-Tarakameh A; Keil B; Eryaman Y; Atalar E; Golestanirad L
PLoS One; 2023; 18(1):e0280655. PubMed ID: 36701285
[TBL] [Abstract][Full Text] [Related]
8. The effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel-transmit pulses at 7 T.
Herrler J; Williams SN; Liebig P; Ding B; McElhinney P; Allwood-Spiers S; Meixner CR; Gunamony S; Maier A; Dörfler A; Gumbrecht R; Porter DA; Nagel AM
Magn Reson Med; 2023 May; 89(5):1888-1900. PubMed ID: 36622945
[TBL] [Abstract][Full Text] [Related]
9. Intersubject local SAR variation for 7T prostate MR imaging with an eight-channel single-side adapted dipole antenna array.
Ipek O; Raaijmakers AJ; Lagendijk JJ; Luijten PR; van den Berg CA
Magn Reson Med; 2014 Apr; 71(4):1559-67. PubMed ID: 23754584
[TBL] [Abstract][Full Text] [Related]
10. Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging.
Seo JH; Ryu Y; Chung JY
Sensors (Basel); 2022 Jun; 22(11):. PubMed ID: 35684895
[TBL] [Abstract][Full Text] [Related]
11. The dual-mode dipole: A new array element for 7T body imaging with reduced SAR.
Solomakha G; Leeuwen CV; Raaijmakers A; Simovski C; Popugaev A; Abdeddaim R; Melchakova I; Glybovski S
Magn Reson Med; 2019 Feb; 81(2):1459-1469. PubMed ID: 30226636
[TBL] [Abstract][Full Text] [Related]
12. Bench to bore ramifications of inter-subject head differences on RF shimming and specific absorption rates at 7T.
Hardy BM; Banik R; Yan X; Anderson AW
Magn Reson Imaging; 2022 Oct; 92():187-196. PubMed ID: 35842192
[TBL] [Abstract][Full Text] [Related]
13. A pathway towards a two-dimensional, bore-mounted, volume body coil concept for ultra high-field magnetic resonance imaging.
Gokyar S; Voss HU; Taracila V; Robb FJL; Bernico M; Kelley D; Ballon DJ; Winkler SA
NMR Biomed; 2022 Dec; 35(12):e4802. PubMed ID: 35834176
[TBL] [Abstract][Full Text] [Related]
14. SAR and temperature distributions in a database of realistic human models for 7 T cardiac imaging.
Steensma BR; Meliadò EF; Luijten P; Klomp DWJ; van den Berg CAT; Raaijmakers AJE
NMR Biomed; 2021 Jul; 34(7):e4525. PubMed ID: 33955061
[TBL] [Abstract][Full Text] [Related]
15. An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T.
Kraff O; Bitz AK; Dammann P; Ladd SC; Ladd ME; Quick HH
Med Phys; 2010 Dec; 37(12):6368-76. PubMed ID: 21302794
[TBL] [Abstract][Full Text] [Related]
16. A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla.
Woo MK; DelaBarre L; Waks M; Radder J; Choi US; Lagore R; Ugurbil K; Adriany G
Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770558
[TBL] [Abstract][Full Text] [Related]
17. 7T MR Thermometry technique for validation of system-predicted SAR with a home-built radiofrequency wrist coil.
Fagan AJ; Jacobs PS; Hulshizer TC; Rossman PJ; Frick MA; Amrami KK; Felmlee JP
Med Phys; 2021 Feb; 48(2):781-790. PubMed ID: 33294999
[TBL] [Abstract][Full Text] [Related]
18. Investigation of alternative RF power limit control methods for 0.5T, 1.5T, and 3T parallel transmission cardiac imaging: A simulation study.
Petzold J; Schmitter S; Silemek B; Winter L; Speck O; Ittermann B; Seifert F
Magn Reson Med; 2024 Apr; 91(4):1659-1675. PubMed ID: 38031517
[TBL] [Abstract][Full Text] [Related]
19. The impact of respiratory motion on electromagnetic fields and specific absorption rate in cardiac imaging at 7T.
Schoen N; Seifert F; Petzold J; Metzger GJ; Speck O; Ittermann B; Schmitter S
Magn Reson Med; 2022 Dec; 88(6):2645-2661. PubMed ID: 35906923
[TBL] [Abstract][Full Text] [Related]
20. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T.
Destruel A; Fuentes M; Weber E; O'Brien K; Jin J; Liu F; Barth M; Crozier S
Magn Reson Med; 2019 Jun; 81(6):3826-3839. PubMed ID: 30803001
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]