146 related articles for article (PubMed ID: 36372227)
1. Vial Breakage in Lyophilization- Case Studies from Commercial Manufacturing and Laboratory Studies.
Sahni EK; Searles JA; Nachtigall M; Owen E; Lyne D
J Pharm Sci; 2023 Apr; 112(4):1151-1159. PubMed ID: 36372227
[TBL] [Abstract][Full Text] [Related]
2. Novel Mechanism of Glass Delamination in Type 1A Borosilicate Vials Containing Frozen Protein Formulations.
Jiang G; Goss M; Li G; Jing W; Shen H; Fujimori K; Le L; Wong L; Wen ZQ; Nashed-Samuel Y; Riker K; Germansderfer A; Tsang P; Ricci M
PDA J Pharm Sci Technol; 2013; 67(4):323-35. PubMed ID: 23872443
[TBL] [Abstract][Full Text] [Related]
3. Failure of Glass Tubing Vials during Lyophilization.
Machak DR; Smay GL
PDA J Pharm Sci Technol; 2019; 73(1):30-38. PubMed ID: 30361283
[TBL] [Abstract][Full Text] [Related]
4. Freeze Drying and Vial Breakage: Misconceptions, Root Causes and Mitigation Strategies for the Pharmaceutical Industry.
Jin X; O'Grady D; Affleck RP; Martini S; Saluja A
J Pharm Sci; 2024 May; 113(5):1306-1318. PubMed ID: 38103690
[TBL] [Abstract][Full Text] [Related]
5. Impact of chamber wall temperature on energy transfer during freeze-drying.
Ehlers S; Friess W; Schroeder R
Int J Pharm; 2021 Jan; 592():120025. PubMed ID: 33137451
[TBL] [Abstract][Full Text] [Related]
6. Mechanistic studies of glass vial breakage for frozen formulations. II. Vial breakage caused by amorphous protein formulations.
Jiang G; Akers M; Jain M; Guo J; Distler A; Swift R; Wadhwa MV; Jameel F; Patro S; Freund E
PDA J Pharm Sci Technol; 2007; 61(6):452-60. PubMed ID: 18410046
[TBL] [Abstract][Full Text] [Related]
7. Molded Vial Manufacturing and Its Impact on Heat Transfer during Freeze-Drying: Vial Geometry Considerations.
Wenzel T; Gieseler H
AAPS PharmSciTech; 2021 Jan; 22(2):57. PubMed ID: 33502633
[TBL] [Abstract][Full Text] [Related]
8. Mechanistic studies of glass vial breakage for frozen formulations. I. Vial breakage caused by crystallizable excipient mannitol.
Jiang G; Akers M; Jain M; Guo J; Distler A; Swift R; Wadhwa MV; Jameel F; Patro S; Freund E
PDA J Pharm Sci Technol; 2007; 61(6):441-51. PubMed ID: 18410045
[TBL] [Abstract][Full Text] [Related]
9. Effect of the design of the stopper including dimension, type, and vent area on lyophilization process.
Mungikar A; Ludzinski M; Kamat M
PDA J Pharm Sci Technol; 2010; 64(6):507-16. PubMed ID: 21502061
[TBL] [Abstract][Full Text] [Related]
10. Thermal mechanical analysis of frozen solutions of mannitol and some related stereoisomers: evidence of expansion during warming and correlation with vial breakage during lyophilization.
Williams NA; Guglielmo J
J Parenter Sci Technol; 1993; 47(3):119-23. PubMed ID: 8360803
[TBL] [Abstract][Full Text] [Related]
11. Impact of Natural Variations in Freeze-Drying Parameters on Product Temperature History: Application of Quasi Steady-State Heat and Mass Transfer and Simple Statistics.
Pikal MJ; Pande P; Bogner R; Sane P; Mudhivarthi V; Sharma P
AAPS PharmSciTech; 2018 Oct; 19(7):2828-2842. PubMed ID: 30259404
[TBL] [Abstract][Full Text] [Related]
12. Comparative Leachable Study of Glass Vials to Demonstrate the Impact of Low Fill Volume.
Hladik B; Buscke F; Frost R; Rothhaar U
PDA J Pharm Sci Technol; 2019; 73(4):345-355. PubMed ID: 30770482
[TBL] [Abstract][Full Text] [Related]
13. A method to quantitatively define and assess the risk of cosmetic glass defects on tubing glass vials.
Loui AW
PDA J Pharm Sci Technol; 2011; 65(4):380-91. PubMed ID: 22293525
[TBL] [Abstract][Full Text] [Related]
14. Investigating factors leading to fogging of glass vials in lyophilized drug products.
Abdul-Fattah AM; Oeschger R; Roehl H; Bauer Dauphin I; Worgull M; Kallmeyer G; Mahler HC
Eur J Pharm Biopharm; 2013 Oct; 85(2):314-26. PubMed ID: 23791681
[TBL] [Abstract][Full Text] [Related]
15. Trouble With the Neighbor During Freeze-Drying: Rivalry About Energy.
Ehlers S; Schroeder R; Friess W
J Pharm Sci; 2021 Mar; 110(3):1219-1226. PubMed ID: 33069707
[TBL] [Abstract][Full Text] [Related]
16. Process optimization and transfer of freeze-drying in nested vial systems.
Ehlers S; Schroeder R; Friess W
Eur J Pharm Biopharm; 2021 Feb; 159():143-150. PubMed ID: 33429009
[TBL] [Abstract][Full Text] [Related]
17. Representative Scale-Down Lyophilization Cycle Development Using a Seven-Vial Freeze-Dryer (MicroFD
Goldman JM; Chen X; Register JT; Nesarikar V; Iyer L; Wu Y; Mugheirbi N; Rowe J
J Pharm Sci; 2019 Apr; 108(4):1486-1495. PubMed ID: 30468831
[TBL] [Abstract][Full Text] [Related]
18. Freeze-Drying Process Development and Scale-Up: Scale-Up of Edge Vial Versus Center Vial Heat Transfer Coefficients, K
Pikal MJ; Bogner R; Mudhivarthi V; Sharma P; Sane P
J Pharm Sci; 2016 Nov; 105(11):3333-3343. PubMed ID: 27666376
[TBL] [Abstract][Full Text] [Related]
19. Impact of Vial Washing and Depyrogenation on Surface Properties and Delamination Risk of Glass Vials.
Ditter D; Mahler HC; Gohlke L; Nieto A; Roehl H; Huwyler J; Wahl M; Allmendinger A
Pharm Res; 2018 May; 35(7):146. PubMed ID: 29796727
[TBL] [Abstract][Full Text] [Related]
20. Comparison of vial heat transfer coefficients during the primary and secondary drying stages of freeze-drying.
Yoon K; Narsimhan V
Int J Pharm; 2023 Mar; 635():122746. PubMed ID: 36812952
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]