These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 36396215)

  • 1. Pacemaker Malfunction-Review of Permanent Pacemakers and Malfunctions Encountered in the Emergency Department.
    White WB; Berberian JG
    Emerg Med Clin North Am; 2022 Nov; 40(4):679-691. PubMed ID: 36396215
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports.
    Maisel WH; Moynahan M; Zuckerman BD; Gross TP; Tovar OH; Tillman DB; Schultz DB
    JAMA; 2006 Apr; 295(16):1901-6. PubMed ID: 16639048
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Permanent cardiac pacemakers: issues relevant to the emergency physician, Part I.
    Cardall TY; Chan TC; Brady WJ; Perry JC; Vilke GM; Rosen P
    J Emerg Med; 1999; 17(3):479-89. PubMed ID: 10338243
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pacemaker and ICD generator reliability: meta-analysis of device registries.
    Maisel WH
    JAMA; 2006 Apr; 295(16):1929-34. PubMed ID: 16639052
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pacemaker follow-up: its role in the detection and correction of pacemaker system malfunction.
    Griffin JC; Schuenemeyer TD; Hess KR; Glaeser D; Anderson BJ; Romans E; Jenkins MA; Nielsen AP
    Pacing Clin Electrophysiol; 1986 May; 9(3):387-91. PubMed ID: 2423980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Managing pacemaker-related complications and malfunctions in the emergency department.
    Martindale J; deSouza IS
    Emerg Med Pract; 2014 Sep; 16(9):1-21; quiz 21-2. PubMed ID: 25436255
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Permanent cardiac pacemakers: issues relevant to the emergency physician, part II.
    Cardall TY; Brady WJ; Chan TC; Perry JC; Vilke GM; Rosen P
    J Emerg Med; 1999; 17(4):697-709. PubMed ID: 10431963
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency of pacemaker malfunction associated with monopolar electrosurgery during pulse generator replacement or upgrade surgery.
    Lin Y; Melby DP; Krishnan B; Adabag S; Tholakanahalli V; Li JM
    J Interv Card Electrophysiol; 2017 Aug; 49(2):205-209. PubMed ID: 28413855
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How pacemakers work and simple programming: a primer for the non-electrophysiologist.
    Chiu-Man C
    Cardiol Young; 2017 Jan; 27(S1):S115-S120. PubMed ID: 28084968
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac pacemakers: evaluation and management of malfunctions.
    Sarko JA; Tiffany BR
    Am J Emerg Med; 2000 Jul; 18(4):435-40. PubMed ID: 10919534
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pacemaker malfunction.
    Hayes DL; Vlietstra RE
    Ann Intern Med; 1993 Oct; 119(8):828-35. PubMed ID: 8379604
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of percutaneous catheter ablation on preexisting permanent pacemakers.
    Vanerio G; Maloney J; Rashidi R; McCowan R; Castle L; Morant V; Wilkoff B; Simmons T
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 1):1637-45. PubMed ID: 1704517
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Function of ventricular pacemakers during resuscitation.
    Zullo MA
    Pacing Clin Electrophysiol; 1990 Jun; 13(6):736-44. PubMed ID: 1695354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Counterclockwise exit of cardiac pacemaker leads: sign of pulse-generator flip.
    Karis JP; Ravin CE
    Radiology; 1990 Mar; 174(3 Pt 1):711-2. PubMed ID: 2305054
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experience with pacemaker pulse generators and transvenous leads: an 8-year prospective multicenter study.
    Hauser RG; Hayes DL; Kallinen LM; Cannom DS; Epstein AE; Almquist AK; Song SL; Tyers GF; Vlay SC; Irwin M
    Heart Rhythm; 2007 Feb; 4(2):154-60. PubMed ID: 17275749
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Functional disorders of cardiac pacemakers--their diagnosis and treatment].
    Udin D; Lazarov S; Todorov A
    Khirurgiia (Sofiia); 1989; 42(6):74-9. PubMed ID: 2699506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Superiority of multiprogrammable to nonprogrammable VVI pacing: a comparative study with special reference to management of pacing system malfunctions.
    Pless P; Simonsen E; Arnsbo P; Fabricius J
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):739-44. PubMed ID: 2429281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Common pitfalls in interpreting pacemaker electrocardiograms in the emergency department.
    Venkatachalam KL
    J Electrocardiol; 2011; 44(6):616-21. PubMed ID: 21907995
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The combined transvenous implantation of cardioverter defibrillators and permanent pacemakers.
    Mattke S; Markewitz A; Müller D; Grünewald A; Fiek M; Schmöckel M; Hoffmann E; Steinbeck G
    Pacing Clin Electrophysiol; 1997 Nov; 20(11):2775-82. PubMed ID: 9392808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Temporary epicardial pacing after cardiac surgery: a practical review. Part 2: Selection of epicardial pacing modes and troubleshooting.
    Reade MC
    Anaesthesia; 2007 Apr; 62(4):364-73. PubMed ID: 17381573
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.