These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 36402626)

  • 21. Torque Maintenance of Screw-Retained Implant-Supported Anterior Fixed Dental Prosthesis with Different Abutment Angulations After Aging.
    Al-Zordk W; Al-Dobaisi T; Ghazy M
    Int J Oral Maxillofac Implants; 2021; 36(4):723-729. PubMed ID: 34411211
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections.
    Koosha S; Toraji S; Mostafavi AS
    J Prosthet Dent; 2020 Apr; 123(4):618-621. PubMed ID: 31353109
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Loss of preload in screwed implant joints as a function of time and tightening/untightening sequences.
    Bernardes SR; da Gloria Chiarello de Mattos M; Hobkirk J; Ribeiro RF
    Int J Oral Maxillofac Implants; 2014; 29(1):89-96. PubMed ID: 24451858
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of tightening torque on screw stress and formation of implant-abutment microgaps: A finite element analysis.
    Honório Tonin BS; He Y; Ye N; Chew HP; Fok A
    J Prosthet Dent; 2022 Jun; 127(6):882-889. PubMed ID: 33472752
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Finite element analysis to determine implant preload.
    Lang LA; Kang B; Wang RF; Lang BR
    J Prosthet Dent; 2003 Dec; 90(6):539-46. PubMed ID: 14668754
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants.
    Park JM; Baek CH; Heo SJ; Kim SK; Koak JY; Kim SK; Belser UC
    Int J Oral Maxillofac Implants; 2017; 32(2):350-355. PubMed ID: 28291853
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of abutment angulation on loss of prosthetic abutment torque under mechanical cycling.
    Hein D; Joly JC; Napimoga MH; Peruzzo DC; Martinez EF
    J Prosthet Dent; 2021 Feb; 125(2):349.e1-349.e6. PubMed ID: 33198992
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
    Dailey B; Jordan L; Blind O; Tavernier B
    Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of Different Retightening Procedures on Screw Stability in External-Hex and Internal Trichannel Connections: An In Vitro Study.
    Sun J; Yoda N; Matsudate Y; Hong G; Kawata T; Sasaki K
    Int J Prosthodont; 2023 May; 36(2):181-188. PubMed ID: 33662065
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Protecting critical connection sites of a custom cast abutment with a protector cap during fabrication.
    Wadhwani CPK; Chung KH
    J Prosthet Dent; 2020 Aug; 124(2):144-147. PubMed ID: 31780106
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of Screw Channel Angulation on Reverse Torque Values of Dental Implant Abutment Screws.
    Hu E; Petrich A; Imamura G; Hamlin C
    J Prosthodont; 2019 Dec; 28(9):969-972. PubMed ID: 31560132
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of Abutment Screw Design and Crown/Implant Ratio on Preload Maintenance of Single-Crown Screw-Retained Implant-Supported Prostheses.
    Rodrigues I; Zanardi P; Sesma N
    Int J Oral Maxillofac Implants; 2019; 34(6):1397-1403. PubMed ID: 31711081
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of repeated torque in small diameter implants with machined and premachined abutments.
    Saboury A; Neshandar Asli H; Vaziri S
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e224-30. PubMed ID: 22376004
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs.
    Vinhas AS; Aroso C; Salazar F; Relvas M; Braga AC; Ríos-Carrasco B; Gil J; Rios-Santos JV; Fernández-Palacín A; Herrero-Climent M
    Materials (Basel); 2022 Feb; 15(4):. PubMed ID: 35207933
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Removal torque and force to failure of non-axially tightened implant abutment screws.
    Goldberg J; Lee T; Phark JH; Chee W
    J Prosthet Dent; 2019 Feb; 121(2):322-326. PubMed ID: 30139673
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical Assessment of Preload Maintenance in the Abutment Screws of Single Posterior Implants After 1 Month of Use.
    Xu Y; Li W; Su M
    Int J Oral Maxillofac Implants; 2021; 36(1):177-181. PubMed ID: 33600539
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?
    Siadat H; Pirmoazen S; Beyabanaki E; Alikhasi M
    J Oral Implantol; 2015 Jul; 41 Spec No():346-51. PubMed ID: 26237093
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fit and Stability of Screw-Retained Implant-Supported Frameworks Under Masticatory Simulation: Influence of Cylinder Type.
    Bhering CL; Marques Ida S; Takahashi JM; Barão VA; Consani RL; Mesquita MF
    J Prosthodont; 2016 Aug; 25(6):459-65. PubMed ID: 26465960
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.