These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 36403396)

  • 21. Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes.
    Nedopil AJ; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3118-3127. PubMed ID: 31768572
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Medial stabilised total knee arthroplasty achieves comparable clinical outcomes when compared to other TKA designs: a systematic review and meta-analysis of the current literature.
    Nisar S; Ahmad K; Palan J; Pandit H; van Duren B
    Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):638-651. PubMed ID: 33247352
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Comparative study on imaging and clinical results of patellofemoral joint with kinematic alignment and mechanical alignment in total knee arthroplasty].
    Wen L; Zhao XX; Wang ZW; Ma DS; Zhang QX; Zhou L; Pan J; Lin Y
    Zhonghua Wai Ke Za Zhi; 2022 Nov; 60(11):1004-1010. PubMed ID: 36323583
    [No Abstract]   [Full Text] [Related]  

  • 24. Kinematically Aligned Total Knee Arthroplasty or Mechanically Aligned Total Knee Arthroplasty.
    Takahashi T; Ansari J; Pandit HG
    J Knee Surg; 2018 Nov; 31(10):999-1006. PubMed ID: 29444542
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Kinematic alignment is bone and soft tissue preserving compared to mechanical alignment in total knee arthroplasty.
    An VVG; Twiggs J; Leie M; Fritsch BA
    Knee; 2019 Mar; 26(2):466-476. PubMed ID: 30772187
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of the Radiologic, Morphometric, and Clinical Outcomes between Kinematically and Mechanically Aligned Total Knee Arthroplasty: A Propensity Matching Study.
    Kim TW; Lee JI; Choi HG; Yoo HJ; Kim KT; Lee YS
    J Knee Surg; 2022 Nov; 35(13):1453-1461. PubMed ID: 33657622
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Kinematic Alignment May Reduce Opioid Consumption and Length of Stay Compared to Mechanically Aligned Total Knee Arthroplasty.
    Lung BE; Donnelly MR; McLellan M; Callan K; Amirhekmat A; McMaster WC; Yang S; So DH
    Orthop Surg; 2023 Feb; 15(2):432-439. PubMed ID: 36444954
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [A comparative analysis of the efficacy of Advance(®) medial pivot prosthesis knee arthroplasty with posterior cruciate ligament retention or substituting based on propensity score matching].
    Xu XP; Guo PC; Gao HS; Sun Y; Wang YZ; Zhang HN
    Zhonghua Yi Xue Za Zhi; 2020 Jan; 100(3):187-191. PubMed ID: 32008284
    [No Abstract]   [Full Text] [Related]  

  • 29. Calipered kinematic alignment restored the arithmetic hip-knee-ankle angle, achieved high satisfaction and improved clinical outcomes.
    Suzuki L; Munir S; Hellman J
    Knee Surg Sports Traumatol Arthrosc; 2024 May; 32(5):1228-1239. PubMed ID: 38477107
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Joint Line Modification in Kinematically Aligned Total Knee Arthroplasty Improves Functional Activity but Not Patient Satisfaction.
    Niki Y; Kobayashi S; Nagura T; Udagawa K; Harato K
    J Arthroplasty; 2018 Jul; 33(7):2125-2130. PubMed ID: 29506930
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.
    Lee YS; Howell SM; Won YY; Lee OS; Lee SH; Vahedi H; Teo SH
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3467-3479. PubMed ID: 28439636
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Good clinical results using a modified kinematic alignment technique with a cruciate sacrificing medially stabilised total knee arthroplasty.
    Malavolta M; Compagnoni R; Mezzari S; Calanna F; Pastrone A; Randelli P
    Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):500-506. PubMed ID: 32748231
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Verasense sensor-assisted total knee arthroplasty showed no difference in range of motion, reoperation rate or functional outcomes when compared to manually balanced total knee arthroplasty: a systematic review.
    Sava MP; Hara H; Alexandra L; Hügli RW; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2023 May; 31(5):1851-1858. PubMed ID: 36854996
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of plantar pressure distribution during walking and lower limb alignment between modified kinematically and mechanically aligned total knee arthroplasty.
    Kamenaga T; Nakano N; Takayama K; Tsubosaka M; Takashima Y; Kikuchi K; Fujita M; Kuroda Y; Hashimoto S; Hayashi S; Niikura T; Kuroda R; Matsumoto T
    J Biomech; 2021 May; 120():110379. PubMed ID: 33839483
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Functional positioning principles for image-based robotic-assisted TKA achieved a higher Forgotten Joint Score at 1 year compared to conventional TKA with restricted kinematic alignment.
    Kafelov M; Batailler C; Shatrov J; Al-Jufaili J; Farhat J; Servien E; Lustig S
    Knee Surg Sports Traumatol Arthrosc; 2023 Dec; 31(12):5591-5602. PubMed ID: 37851026
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A Randomized Controlled Trial of Kinematically and Mechanically Aligned Total Knee Arthroplasties: Long-Term Follow-Up.
    Dossett HG; Arthur JR; Makovicka JL; Mara KC; Bingham JS; Clarke HD; Spangehl MJ
    J Arthroplasty; 2023 Jun; 38(6S):S209-S214. PubMed ID: 37003458
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Kinematic aligned femoral rotation leads to greater patella tilt but similar clinical outcomes when compared to traditional femoral component rotation in total knee arthroplasty. A propensity score matched study.
    Koh DTS; Woo YL; Yew AKS; Yeo SJ
    Knee Surg Sports Traumatol Arthrosc; 2021 Apr; 29(4):1059-1066. PubMed ID: 32488370
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Kinematically aligned total knee arthroplasty restores more native medial collateral ligament strain than mechanically aligned total knee arthroplasty.
    Lim D; Kwak DS; Kim M; Kim S; Cho HJ; Choi JH; Koh IJ
    Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2815-2823. PubMed ID: 34312712
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A cruciate-retaining implant can treat both knees of most windswept deformities when performed with calipered kinematically aligned TKA.
    Howell SM; Shelton TJ; Gill M; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):437-445. PubMed ID: 32239272
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Robotic-assisted surgery and kinematic alignment in total knee arthroplasty (RASKAL study): a protocol of a national registry-nested, multicentre, 2×2 factorial randomised trial assessing clinical, intraoperative, functional, radiographic and survivorship outcomes.
    MacDessi SJ; Wernecke GC; Bastiras D; Hooper T; Heath E; Lorimer M; Harris I;
    BMJ Open; 2022 Jun; 12(6):e051088. PubMed ID: 35688590
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.