These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 36411083)

  • 1. Rapid Measurement of Lactate in the Exhaled Breath Condensate: Biosensor Optimization and In-Human Proof of Concept.
    Zhang S; Chen YC; Riezk A; Ming D; Tsvik L; Sützl L; Holmes A; O'Hare D
    ACS Sens; 2022 Dec; 7(12):3809-3816. PubMed ID: 36411083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Measurements of L-lactate and H2O2 in exhaled breath condensate at rest and mild to moderate exercise in young and healthy subjects].
    Marek E; Mückenhoff K; Streckert HJ; Becher G; Marek W
    Pneumologie; 2008 Sep; 62(9):541-7. PubMed ID: 18546081
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurements of lactate in exhaled breath condensate at rest and after maximal exercise in young and healthy subjects.
    Marek EM; Volke J; Hawener I; Platen P; Mückenhoff K; Marek W
    J Breath Res; 2010 Mar; 4(1):017105. PubMed ID: 21386210
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of an accurate and sensitive method for lactate analysis in exhaled breath condensate by LC MS/MS.
    Jackson TC; Zhang YV; Sime PJ; Phipps RP; Kottmann RM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Sep; 1061-1062():468-473. PubMed ID: 28822945
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lactate in exhaled breath condensate and its correlation to cancer: challenges, promises and a call for data.
    Ruzsányi V; Kalapos MP
    J Breath Res; 2023 Jul; 17(4):. PubMed ID: 37433292
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exhaled breath condensate based breath analyser - a disposable hydrogen peroxide sensor and smart analyser.
    Chen YC; O'Hare D
    Analyst; 2020 May; 145(10):3549-3556. PubMed ID: 32319459
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EBC-SURE (exhaled breath condensate- scanning using rapid electro analytics): A non-faradaic and non-invasive electrochemical assay to screen for pro-inflammatory biomarkers in human breath condensate.
    Bhide A; Pali M; Muthukumar S; Prasad S
    Biosens Bioelectron; 2022 Jun; 206():114117. PubMed ID: 35247857
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Determination of organic acids and anions in exhaled breath by condensation collection-ion chromatography].
    Gan L; Zhou YY; Fang QQ; Xu JJ; Chen SQ; Zhu Y; Ni CZ
    Se Pu; 2024 Mar; 42(3):275-281. PubMed ID: 38503704
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioanalysis of underivatized amino acids in non-invasive exhaled breath condensate samples using liquid chromatography coupled with tandem mass spectrometry.
    Konieczna L; Pyszka M; Okońska M; Niedźwiecki M; Bączek T
    J Chromatogr A; 2018 Mar; 1542():72-81. PubMed ID: 29477235
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel electrochemical sensor based on ion imprinted polymer and gold nanomaterials for nitrite ion analysis in exhaled breath condensate.
    Diouf A; El Bari N; Bouchikhi B
    Talanta; 2020 Mar; 209():120577. PubMed ID: 31892035
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analytical methodologies for broad metabolite coverage of exhaled breath condensate.
    Aksenov AA; Zamuruyev KO; Pasamontes A; Brown JF; Schivo M; Foutouhi S; Weimer BC; Kenyon NJ; Davis CE
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Sep; 1061-1062():17-25. PubMed ID: 28697414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Capillary electrophoresis--a new tool for ionic analysis of exhaled breath condensate.
    Kubáň P; Kobrin EG; Kaljurand M
    J Chromatogr A; 2012 Dec; 1267():239-45. PubMed ID: 22796027
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Exhaled breath condensate identifies metabolic dysregulation in patients with radiation-induced lung injury.
    Pierre-Louis Odoom J; Freeberg MAT; Camus SV; Toft R; Szomju BB; Sanchez Rosado RM; Jackson PD; Allegood JC; Silvey S; Liu J; Cowart LA; Weiss E; Thatcher TH; Sime PJ
    Am J Physiol Lung Cell Mol Physiol; 2023 Jun; 324(6):L863-L869. PubMed ID: 37039378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a method for metabolomic analysis of human exhaled breath condensate by gas chromatography-mass spectrometry in high resolution mode.
    Peralbo-Molina A; Calderón-Santiago M; Priego-Capote F; Jurado-Gámez B; Luque de Castro MD
    Anal Chim Acta; 2015 Aug; 887():118-126. PubMed ID: 26320793
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of H2O2 and pH in exhaled breath condensate samples: methodical and physiological aspects.
    Knobloch H; Becher G; Decker M; Reinhold P
    Biomarkers; 2008 May; 13(3):319-41. PubMed ID: 18415804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of Human and Bovine Exhaled Breath Condensate pH Using Polyaniline-Modified Flexible Inkjet-Printed Nanocarbon Electrodes.
    Jacobs AI; Prete MC; Lesch A; Sebio AA; Teixeira Tarley CR; Swain GM
    ACS Omega; 2024 Oct; 9(39):40841-40856. PubMed ID: 39371969
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A non-invasive method for the detection of glucose in human exhaled breath by condensation collection coupled with ion chromatography.
    Zhou YY; Chen JP; Gan L; Xu W; Liu Y; Zhao YG; Zhu Y
    J Chromatogr A; 2022 Dec; 1685():463564. PubMed ID: 36323098
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Humidity prevents the exercise-induced formation of hydrogen peroxide and nitrite in exhaled breath condensate in recreational cyclists.
    Contreras-Briceño F; Espinosa-Ramirez M; Viscor G; Araneda OF
    Eur J Appl Physiol; 2020 Oct; 120(10):2339-2348. PubMed ID: 32772245
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer.
    Shimomura T; Sumiya T; Ono M; Ito T; Hanaoka TA
    Anal Chim Acta; 2012 Feb; 714():114-20. PubMed ID: 22244144
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ion mobility and liquid chromatography/mass spectrometry strategies for exhaled breath condensate glucose quantitation in cystic fibrosis studies.
    Monge ME; Pérez JJ; Dwivedi P; Zhou M; McCarty NA; Stecenko AA; Fernández FM
    Rapid Commun Mass Spectrom; 2013 Oct; 27(20):2263-71. PubMed ID: 24019192
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.