These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
208 related articles for article (PubMed ID: 36415012)
1. Implant deformation and implant-abutment fracture resistance after standardized artificial aging: An in vitro study. Zhai Z; Nakano T; Chen Y; Watanabe S; Matsuoka T; Ishigaki S Clin Implant Dent Relat Res; 2023 Feb; 25(1):107-117. PubMed ID: 36415012 [TBL] [Abstract][Full Text] [Related]
2. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept. Sailer I; Asgeirsson AG; Thoma DS; Fehmer V; Aspelund T; Özcan M; Pjetursson BE Clin Oral Implants Res; 2018 Apr; 29(4):411-423. PubMed ID: 29527740 [TBL] [Abstract][Full Text] [Related]
10. In vitro performance of zirconia and titanium implant/abutment systems for anterior application. Rosentritt M; Hagemann A; Hahnel S; Behr M; Preis V J Dent; 2014 Aug; 42(8):1019-26. PubMed ID: 24699071 [TBL] [Abstract][Full Text] [Related]
11. Influence of the Titanium Base Abutment Design on Monolithic Zirconia Multiple-Unit Implant Fixed Dental Prostheses: A Laboratory Study. Calderon U; Hicklin SP; Mojon P; Fehmer V; Nesic D; Mekki M; Sailer I Int J Oral Maxillofac Implants; 2022; 37(1):19-29. PubMed ID: 35235616 [TBL] [Abstract][Full Text] [Related]
12. Fracture resistance and crystal phase transformation of a one- and a two-piece zirconia implant with and without simultaneous loading and aging-An in vitro study. Burkhardt F; Spies BC; Riemer L; Adolfsson E; Doerken S; Kohal RJ Clin Oral Implants Res; 2021 Nov; 32(11):1288-1298. PubMed ID: 34352139 [TBL] [Abstract][Full Text] [Related]
13. In vitro performance of two-piece zirconia implant systems for anterior application. Preis V; Kammermeier A; Handel G; Rosentritt M Dent Mater; 2016 Jun; 32(6):765-74. PubMed ID: 27068740 [TBL] [Abstract][Full Text] [Related]
14. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores. Stimmelmayr M; Sagerer S; Erdelt K; Beuer F Int J Oral Maxillofac Implants; 2013; 28(2):488-93. PubMed ID: 23527351 [TBL] [Abstract][Full Text] [Related]
15. Fracture strength of implant abutments after fatigue testing: A systematic review and a meta-analysis. Coray R; Zeltner M; Özcan M J Mech Behav Biomed Mater; 2016 Sep; 62():333-346. PubMed ID: 27239815 [TBL] [Abstract][Full Text] [Related]
16. Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments. AlAmar M; Alqahtani F J Oral Implantol; 2020 Apr; 46(2):88-92. PubMed ID: 31909678 [TBL] [Abstract][Full Text] [Related]
17. Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments. Elsayed A; Wille S; Al-Akhali M; Kern M Clin Oral Implants Res; 2018 Jan; 29(1):20-27. PubMed ID: 28664585 [TBL] [Abstract][Full Text] [Related]
18. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study. Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964 [TBL] [Abstract][Full Text] [Related]
19. Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants. Ma R; Yu P; Zhang Y; Xie C; Tan X; Sun J; Yu H Clin Oral Investig; 2023 Jan; 27(1):221-233. PubMed ID: 36161530 [TBL] [Abstract][Full Text] [Related]
20. Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment. Kohal RJ; von Schierholz C; Nold J; Spies BC; Adolfsson E; Vach K; Burkhardt F Clin Oral Implants Res; 2023 Feb; 34(2):105-115. PubMed ID: 36444693 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]