These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 36424688)

  • 1. Additional cuff suture provides mechanical advantage for fixation of split-type greater tuberosity fracture of humerus.
    Pisitwattanaporn P; Saengpetch N; Thamyongkit S; Wanitchanont T; Sa-Ngasoongsong P; Aroonjarattham P
    Injury; 2022 Dec; 53(12):4033-4037. PubMed ID: 36424688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.
    Gaudelli C; Ménard J; Mutch J; Laflamme GY; Petit Y; Rouleau DM
    Clin Biomech (Bristol, Avon); 2014 Nov; 29(9):1003-8. PubMed ID: 25246375
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Transosseous Suture as an Alternative to Suture Anchor on Anterior-Avulsion Greater Tuberosity Fragment Fixation in Neer Three-Part Proximal Humeral Fracture: A Biomechanical Study.
    Ju J; Ma M; Ding Z; Zhang Y; Fu Z; Chen J
    Orthop Surg; 2023 Aug; 15(8):2132-2137. PubMed ID: 36331129
    [TBL] [Abstract][Full Text] [Related]  

  • 4. No Contribution of Tension-Reducing Rotator Cuff Sutures on Locking Plate Fixation in a 2-Part Proximal Humerus Fracture Model.
    Sinatra PM; Jernick ML; Bledsoe G; Kaar SG
    J Orthop Trauma; 2014 Aug; 28(8):458-63. PubMed ID: 24375272
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical Contribution of Tension-Reducing Rotator Cuff Sutures in 3-Part Proximal Humerus Fractures.
    Arvesen JE; Gill SW; Sinatra PM; Eng M; Bledsoe G; Kaar SG
    J Orthop Trauma; 2016 Aug; 30(8):e262-6. PubMed ID: 26978137
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Titanium mini locking plate with trans-osseous sutures for the treatment of humeral greater tuberosity fracture osteosynthesis versus PHILOS: a retrospective view.
    Xue G; Chahal K; Lim T; Hu S; Li S; Liu J
    Int Orthop; 2018 Oct; 42(10):2467-2473. PubMed ID: 29500554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Rotator Cuff Augmentation of Proximal Humerus Fracture Fixation.
    El-Gazzar Y; Davis E; Beals TR; Flandry F
    J Surg Orthop Adv; 2022; 31(2):119-122. PubMed ID: 35820099
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures.
    Walker R; Castaneda P; Putnam JG; Schemitsch EH; McKee MD
    J Orthop Trauma; 2020 Jul; 34(7):e233-e238. PubMed ID: 31977668
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new biomechanical classification system for split fractures of the humeral greater tuberosity: guidelines for surgical treatment.
    Liu G; Guo X; Zhao Q; Qin B; Lu J; Bao D; Fu S
    J Orthop Surg Res; 2021 Nov; 16(1):692. PubMed ID: 34819107
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparisons of hook plate and screw fixations in split-type greater tuberosity fractures of the humerus.
    Kuan FC; Hsu KL; Hong CK; Chen Y; Chiang CH; Chang HM; Su WR
    J Shoulder Elbow Surg; 2022 Jun; 31(6):1308-1315. PubMed ID: 35066120
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of tuberosity-based proximal humeral locking plate compared to standard proximal humeral locking plate in varus cantilever bending.
    Saunders PE; Castaneda P; Walker R; McKee MD
    Injury; 2022 Nov; 53(11):3650-3654. PubMed ID: 36057488
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between arthroscopic suture anchor fixation and open plate fixation in the greater tuberosity fracture of the proximal humerus.
    Kim YJ; Ji JH; Park SE; Parikh D; Lee WJ
    Eur J Orthop Surg Traumatol; 2024 Jan; 34(1):621-631. PubMed ID: 37668752
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surgical Treatment of Displaced Greater Tuberosity Fractures of the Humerus.
    Rouleau DM; Mutch J; Laflamme GY
    J Am Acad Orthop Surg; 2016 Jan; 24(1):46-56. PubMed ID: 26700632
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Focus on stability: biomechanical evaluation of external fixation technique versus locking plate osteosynthesis in 3-part proximal humeral fractures.
    Harbrecht A; Hackl M; Leschinger T; Müller LP; Wegmann K
    J Shoulder Elbow Surg; 2022 Aug; 31(8):1666-1673. PubMed ID: 35247574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of cable and suture cerclages for tuberosity reattachment in a 4-part proximal humeral fracture model treated with reverse shoulder arthroplasty.
    Knierzinger D; Heinrichs CH; Hengg C; Konschake M; Kralinger F; Schmoelz W
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1816-1823. PubMed ID: 29779978
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate.
    Gradl G; Stedtfeld HW; Morlock M; Sellenschloh K; Püschel K; Mittlmeier T; Gradl G
    Injury; 2012 Jun; 43(6):734-8. PubMed ID: 21944432
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis.
    Jabran A; Peach C; Zou Z; Ren L
    Biomed Eng Online; 2018 Jan; 17(1):10. PubMed ID: 29370867
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transosseous braided-tape and double-row fixations are better than tension band for avulsion-type greater tuberosity fractures.
    Brais G; Ménard J; Mutch J; Laflamme GY; Petit Y; Rouleau DM
    Injury; 2015; 46(6):1007-12. PubMed ID: 25799475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiographic and clinical results of tension suture fixation using two washers with PHILOS plate for proximal humeral fractures.
    Cho CH; Kim DH; Kim BS
    Injury; 2017 Feb; 48(2):464-468. PubMed ID: 27914660
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures.
    Jabran A; Peach C; Zou Z; Ren L
    Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.