76 related articles for article (PubMed ID: 36426753)
1. Combination of RT-LAMP and fluorescence spectroscopy using chemometric techniques for an ultra-sensitive and rapid alternative for the detection of SARS-CoV-2.
Tessaro L; da Silva Mutz Y; Lelis CA; Andrade JC; Aquino A; Panzenhagen P; Ochioni AC; Sousa Vieira IR; Conte-Junior CA
Anal Methods; 2022 Dec; 14(47):4922-4930. PubMed ID: 36426753
[TBL] [Abstract][Full Text] [Related]
2. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
[TBL] [Abstract][Full Text] [Related]
3. Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique.
Khanizadeh S; Malekshahi A; Hanifehpour H; Birjandi M; Fallahi S
BMC Microbiol; 2023 Mar; 23(1):63. PubMed ID: 36882699
[TBL] [Abstract][Full Text] [Related]
4. Colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a visual diagnostic platform for the detection of the emerging coronavirus SARS-CoV-2.
Nawattanapaiboon K; Pasomsub E; Prombun P; Wongbunmak A; Jenjitwanich A; Mahasupachai P; Vetcho P; Chayrach C; Manatjaroenlap N; Samphaongern C; Watthanachockchai T; Leedorkmai P; Manopwisedjaroen S; Akkarawongsapat R; Thitithanyanont A; Phanchana M; Panbangred W; Chauvatcharin S; Srikhirin T
Analyst; 2021 Jan; 146(2):471-477. PubMed ID: 33165486
[TBL] [Abstract][Full Text] [Related]
5. A novel One-pot rapid diagnostic technology for COVID-19.
Li J; Hu X; Wang X; Yang J; Zhang L; Deng Q; Zhang X; Wang Z; Hou T; Li S
Anal Chim Acta; 2021 Apr; 1154():338310. PubMed ID: 33736798
[TBL] [Abstract][Full Text] [Related]
6. High-Surety Isothermal Amplification and Detection of SARS-CoV-2.
Bhadra S; Riedel TE; Lakhotia S; Tran ND; Ellington AD
mSphere; 2021 May; 6(3):. PubMed ID: 34011690
[TBL] [Abstract][Full Text] [Related]
7. Multisite Clinical Validation of Isothermal Amplification-Based SARS-CoV-2 Detection Assays Using Different Sampling Strategies.
Desai KT; Alfaro K; Mendoza L; Faron M; Mesich B; Maza M; Dominguez R; Valenzuela A; Acosta CD; Martínez M; Felix JC; Masch R; Smith JS; Gabrilovich S; Wu T; Plump M; Novetsky AP; Einstein MH; Douglas NC; Cremer M; Wentzensen N
Microbiol Spectr; 2021 Oct; 9(2):e0084621. PubMed ID: 34668736
[TBL] [Abstract][Full Text] [Related]
8. SARS-CoV-2 detection by fluorescence loop-mediated isothermal amplification with and without RNA extraction.
Taki K; Yokota I; Fukumoto T; Iwasaki S; Fujisawa S; Takahashi M; Negishi S; Hayasaka K; Sato K; Oguri S; Nishida M; Sugita J; Konno S; Saito T; Teshima T
J Infect Chemother; 2021 Feb; 27(2):410-412. PubMed ID: 33214073
[TBL] [Abstract][Full Text] [Related]
9. A Sensitive Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Direct Visual Detection of SARS-CoV-2.
Lau YL; Ismail IB; Izati Binti Mustapa N; Lai MY; Tuan Soh TS; Hassan AH; Peariasamy KM; Lee YL; Goh PP
Am J Trop Med Hyg; 2020 Dec; 103(6):2350-2352. PubMed ID: 33098286
[TBL] [Abstract][Full Text] [Related]
10. Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis.
Rödel J; Egerer R; Suleyman A; Sommer-Schmid B; Baier M; Henke A; Edel B; Löffler B
J Clin Virol; 2020 Nov; 132():104616. PubMed ID: 32891938
[TBL] [Abstract][Full Text] [Related]
11. Effectiveness and cost-effectiveness of four different strategies for SARS-CoV-2 surveillance in the general population (CoV-Surv Study): a structured summary of a study protocol for a cluster-randomised, two-factorial controlled trial.
Deckert A; Anders S; de Allegri M; Nguyen HT; Souares A; McMahon S; Boerner K; Meurer M; Herbst K; Sand M; Koeppel L; Siems T; Brugnara L; Brenner S; Burk R; Lou D; Kirrmaier D; Duan Y; Ovchinnikova S; Marx M; Kräusslich HG; Knop M; Bärnighausen T; Denkinger C
Trials; 2021 Jan; 22(1):39. PubMed ID: 33419461
[TBL] [Abstract][Full Text] [Related]
12. Comparative analysis of loop-mediated isothermal amplification (LAMP)-based assays for rapid detection of SARS-CoV-2 genes.
Urrutia-Cabrera D; Liou RH; Wang JH; Chan J; Hung SS; Hewitt AW; Martin KR; Edwards TL; Kwan P; Wong RC
Sci Rep; 2021 Nov; 11(1):22493. PubMed ID: 34795308
[TBL] [Abstract][Full Text] [Related]
13. ATR-FTIR spectroscopy and chemometrics as a quick and simple alternative for discrimination of SARS-CoV-2 infected food of animal origin.
Tessaro L; Mutz YDS; Andrade JC; Aquino A; Belem NKR; Silva FGS; Conte-Junior CA
Spectrochim Acta A Mol Biomol Spectrosc; 2023 Jan; 285():121883. PubMed ID: 36126622
[TBL] [Abstract][Full Text] [Related]
14. Automated sample-to-answer centrifugal microfluidic system for rapid molecular diagnostics of SARS-CoV-2.
Malic L; Brassard D; Da Fonte D; Nassif C; Mounier M; Ponton A; Geissler M; Shiu M; Morton KJ; Veres T
Lab Chip; 2022 Aug; 22(17):3157-3171. PubMed ID: 35670202
[TBL] [Abstract][Full Text] [Related]
15. Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor.
Chen X; Zhou Q; Li S; Yan H; Chang B; Wang Y; Dong S
Front Cell Infect Microbiol; 2021; 11():581239. PubMed ID: 34336708
[TBL] [Abstract][Full Text] [Related]
16. CLEVER assay: A visual and rapid RNA extraction-free detection of SARS-CoV-2 based on CRISPR-Cas integrated RT-LAMP technology.
Bhatt A; Fatima Z; Ruwali M; Misra CS; Rangu SS; Rath D; Rattan A; Hameed S
J Appl Microbiol; 2022 Aug; 133(2):410-421. PubMed ID: 35396760
[TBL] [Abstract][Full Text] [Related]
17. Performance of colorimetric reverse transcription loop-mediated isothermal amplification as a diagnostic tool for SARS-CoV-2 infection during the fourth wave of COVID-19 in Thailand.
Promlek T; Thanunchai M; Phumisantiphong U; Hansirisathit T; Phuttanu C; Dongphooyao S; Thongsopa W; Nuchnoi P
Int J Infect Dis; 2022 Mar; 116():133-137. PubMed ID: 34958929
[TBL] [Abstract][Full Text] [Related]
18. iSCAN: An RT-LAMP-coupled CRISPR-Cas12 module for rapid, sensitive detection of SARS-CoV-2.
Ali Z; Aman R; Mahas A; Rao GS; Tehseen M; Marsic T; Salunke R; Subudhi AK; Hala SM; Hamdan SM; Pain A; Alofi FS; Alsomali A; Hashem AM; Khogeer A; Almontashiri NAM; Abedalthagafi M; Hassan N; Mahfouz MM
Virus Res; 2020 Oct; 288():198129. PubMed ID: 32822689
[TBL] [Abstract][Full Text] [Related]
19. A fast extraction-free isothermal LAMP assay for detection of SARS-CoV-2 with potential use in resource-limited settings.
Gärtner K; Meleke H; Kamdolozi M; Chaima D; Samikwa L; Paynter M; Nyirenda Nyang'Wa M; Cloutman-Green E; Nastouli E; Klein N; Nyirenda T; Msefula C; Alber DG
Virol J; 2022 May; 19(1):77. PubMed ID: 35501862
[TBL] [Abstract][Full Text] [Related]
20. Development of a RT-LAMP assay for detection of SARS-CoV-2.
Nandi SS; Lambe UP; Sawant SA; Gohil T; Deshpande J
Indian J Med Res; 2022 Jan; 155(1):148-155. PubMed ID: 35313427
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]