These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 36427487)

  • 1. Perspectives in linear accelerator for FLASH VHEE: Study of a compact C-band system.
    Faillace L; Alesini D; Bisogni G; Bosco F; Carillo M; Cirrone P; Cuttone G; De Arcangelis D; De Gregorio A; Di Martino F; Favaudon V; Ficcadenti L; Francescone D; Franciosini G; Gallo A; Heinrich S; Migliorati M; Mostacci A; Palumbo L; Patera V; Patriarca A; Pensavalle J; Perondi F; Remetti R; Sarti A; Spataro B; Torrisi G; Vannozzi A; Giuliano L
    Phys Med; 2022 Dec; 104():149-159. PubMed ID: 36427487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characteristics of very high-energy electron beams for the irradiation of deep-seated targets.
    Böhlen TT; Germond JF; Traneus E; Bourhis J; Vozenin MC; Bailat C; Bochud F; Moeckli R
    Med Phys; 2021 Jul; 48(7):3958-3967. PubMed ID: 33884618
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design, Construction, and Test of Compact, Distributed-Charge, X-Band Accelerator Systems that Enable Image-Guided, VHEE FLASH Radiotherapy.
    Barty CPJ; Algots JM; Amador AJ; Barty JCR; Betts SM; Casteñada MA; Chu MM; Daley ME; De Luna Lopez RA; Diviak DA; Effarah HH; Feliciano R; Garcia A; Grabiel KJ; Griffin AS; Hartemann FV; Heid L; Hwang Y; Imeshev G; Jentschel M; Johnson CA; Kinosian KW; Lagzda A; Lochrie RJ; May MW; Molina E; Nagel CL; Nagel HJ; Peirce KR; Peirce ZR; Quiñonez ME; Raksi F; Ranganath K; Reutershan T; Salazar J; Schneider ME; Seggebruch MWL; Yang JY; Yeung NH; Zapata CB; Zapata LE; Zepeda EJ; Zhang J
    ArXiv; 2024 Aug; ():. PubMed ID: 39148931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Medical X-band linear accelerator for high-precision radiotherapy.
    Lee YS; Kim S; Kim GJ; Lee JH; Kim IS; Kim JI; Shin KY; Seol Y; Oh T; An NY; Lee J; Hwang J; Oh Y; Kang YN
    Med Phys; 2021 Sep; 48(9):5327-5342. PubMed ID: 34224166
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a novel fibre optic beam profile and dose monitor for very high energy electron radiotherapy at ultrahigh dose rates.
    Bateman JJ; Buchanan E; Corsini R; Farabolini W; Korysko P; Garbrecht Larsen R; Malyzhenkov A; Ortega Ruiz I; Rieker V; Gerbershagen A; Dosanjh M
    Phys Med Biol; 2024 Apr; 69(8):. PubMed ID: 38478998
    [No Abstract]   [Full Text] [Related]  

  • 6. SU-E-T-472: Characterization of the Very High Energy Electrons, ISO - 250 MeV (VHEE) Beam Generated by ALPHA-X Laser Wakefield Accelerator Beam Line for Utilization in Monte Carlo Simulation for Biomedical Experiment Planning.
    Moskvin V; Subiel A; Desrosiers C; Wiggins M; Maryanski M; Mendonca M; Boyd M; Sorensen A; Cipiccia S; Issac R; Welsh G; Brunetti E; Aniculaesei C; Jaroszynski DA
    Med Phys; 2012 Jun; 39(6Part17):3813-3814. PubMed ID: 28517464
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implementation and validation of a beam-current transformer on a medical pulsed electron beam LINAC for FLASH-RT beam monitoring.
    Oesterle R; Gonçalves Jorge P; Grilj V; Bourhis J; Vozenin MC; Germond JF; Bochud F; Bailat C; Moeckli R
    J Appl Clin Med Phys; 2021 Nov; 22(11):165-171. PubMed ID: 34609051
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiation shielding and safety implications following linac conversion to an electron FLASH-RT unit.
    Poirier Y; Mossahebi S; Becker SJ; Koger B; Xu J; Lamichhane N; Maxim PG; Sawant A
    Med Phys; 2021 Sep; 48(9):5396-5405. PubMed ID: 34287938
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetically focused 70 MeV proton minibeams for preclinical experiments combining a tandem accelerator and a 3 GHz linear post-accelerator.
    Mayerhofer M; Datzmann G; Degiovanni A; Dimov V; Dollinger G
    Med Phys; 2021 Jun; 48(6):2733-2749. PubMed ID: 33759211
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Technical Note: FLASH radiotherapy monitor chamber signal conditioning.
    Snyder M; Vadas J; Musselwhite J; Halford R; Wilson G; Stevens C; Yan D
    Med Phys; 2021 Feb; 48(2):791-795. PubMed ID: 33296516
    [TBL] [Abstract][Full Text] [Related]  

  • 11. FLASH radiotherapy treatment planning and models for electron beams.
    Rahman M; Trigilio A; Franciosini G; Moeckli R; Zhang R; Böhlen TT
    Radiother Oncol; 2022 Oct; 175():210-221. PubMed ID: 35964763
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.
    Jaccard M; Petersson K; Buchillier T; Germond JF; Durán MT; Vozenin MC; Bourhis J; Bochud FO; Bailat C
    Med Phys; 2017 Feb; 44(2):725-735. PubMed ID: 28019660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Commissioning of an ultra-high dose rate pulsed electron beam medical LINAC for FLASH RT preclinical animal experiments and future clinical human protocols.
    Moeckli R; Gonçalves Jorge P; Grilj V; Oesterle R; Cherbuin N; Bourhis J; Vozenin MC; Germond JF; Bochud F; Bailat C
    Med Phys; 2021 Jun; 48(6):3134-3142. PubMed ID: 33866565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. VHEE FLASH sparing effect measured at CLEAR, CERN with DNA damage of pBR322 plasmid as a biological endpoint.
    Wanstall HC; Korysko P; Farabolini W; Corsini R; Bateman JJ; Rieker V; Hemming A; Henthorn NT; Merchant MJ; Santina E; Chadwick AL; Robertson C; Malyzhenkov A; Jones RM
    Sci Rep; 2024 Jun; 14(1):14803. PubMed ID: 38926450
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electron FLASH radiotherapy in vivo studies. A systematic review.
    Giannini N; Gadducci G; Fuentes T; Gonnelli A; Di Martino F; Puccini P; Naso M; Pasqualetti F; Capaccioli S; Paiar F
    Front Oncol; 2024; 14():1373453. PubMed ID: 38655137
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of an ultra-thin parallel plate ionization chamber for dosimetry in FLASH radiotherapy.
    Gómez F; Gonzalez-Castaño DM; Fernández NG; Pardo-Montero J; Schüller A; Gasparini A; Vanreusel V; Verellen D; Felici G; Kranzer R; Paz-Martín J
    Med Phys; 2022 Jul; 49(7):4705-4714. PubMed ID: 35416306
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.
    Bazalova-Carter M; Qu B; Palma B; Hårdemark B; Hynning E; Jensen C; Maxim PG; Loo BW
    Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053
    [TBL] [Abstract][Full Text] [Related]  

  • 18. VHEE beam dosimetry at CERN Linear Electron Accelerator for Research under ultra-high dose rate conditions.
    Poppinga D; Kranzer R; Farabolini W; Gilardi A; Corsini R; Wyrwoll V; Looe HK; Delfs B; Gabrisch L; Poppe B
    Biomed Phys Eng Express; 2020 Dec; 7(1):. PubMed ID: 34037536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical note: Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studies.
    Gonçalves Jorge P; Grilj V; Bourhis J; Vozenin MC; Germond JF; Bochud F; Bailat C; Moeckli R
    Med Phys; 2022 Mar; 49(3):1831-1838. PubMed ID: 35066878
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel electron accelerator for MRI-Linac radiotherapy.
    Whelan B; Gierman S; Holloway L; Schmerge J; Keall P; Fahrig R
    Med Phys; 2016 Mar; 43(3):1285-94. PubMed ID: 26936713
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.