These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 36450830)

  • 1. Affordable, portable and self-administrable electrical impedance tomography enables global and regional lung function assessment.
    Zouari F; Oon WY; Modak D; Lee WH; Kwok WC; Cao P; Lee WN; Tam TCC; Wong EC; Chan RW
    Sci Rep; 2022 Nov; 12(1):20613. PubMed ID: 36450830
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standalone electrical impedance tomography predicts spirometry indicators and enables regional lung assessment.
    Zouari F; Oon WY; Modak D; Kwok WC; Cao P; Lee WN; Tam TCC; Wong EC; Chan RW
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():3277-3280. PubMed ID: 36085816
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography.
    Lehmann S; Leonhardt S; Ngo C; Bergmann L; Ayed I; Schrading S; Tenbrock K
    Pediatr Pulmonol; 2016 Nov; 51(11):1191-1199. PubMed ID: 27127915
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers.
    Ngo C; Leonhardt S; Zhang T; Lüken M; Misgeld B; Vollmer T; Tenbrock K; Lehmann S
    Physiol Meas; 2017 Jan; 38(1):77-86. PubMed ID: 28004642
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma.
    Ngo C; Dippel F; Tenbrock K; Leonhardt S; Lehmann S
    Pediatr Pulmonol; 2018 May; 53(5):636-644. PubMed ID: 29405616
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis.
    Muller PA; Mueller JL; Mellenthin M; Murthy R; Capps M; Wagner BD; Alsaker M; Deterding R; Sagel SD; Hoppe J
    Physiol Meas; 2018 Apr; 39(4):045008. PubMed ID: 29565263
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation.
    Bodenstein M; Boehme S; Bierschock S; Vogt A; David M; Markstaller K
    BMC Pulm Med; 2014 Apr; 14():73. PubMed ID: 24779960
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrical impedance tomography for predicting failure of spontaneous breathing trials in patients with prolonged weaning.
    Bickenbach J; Czaplik M; Polier M; Marx G; Marx N; Dreher M
    Crit Care; 2017 Jul; 21(1):177. PubMed ID: 28697778
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Regional lung function testing in children using electrical impedance tomography.
    Vogt B; Löhr S; Zhao Z; Falkenberg C; Ankermann T; Weiler N; Frerichs I
    Pediatr Pulmonol; 2018 Mar; 53(3):293-301. PubMed ID: 29136345
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects.
    Riedel T; Richards T; Schibler A
    Intensive Care Med; 2005 Nov; 31(11):1522-8. PubMed ID: 16195908
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimation of changes in cyclic lung strain by electrical impedance tomography: Proof-of-concept study.
    Cornejo R; Iturrieta P; Olegário TMM; Kajiyama C; Arellano D; Guiñez D; Cerda MA; Brito R; Gajardo AIJ; Lazo M; López L; Morais CCA; González S; Zavala M; Rojas V; Medel JN; Hurtado DE; Bruhn A; Ramos C; Estuardo N
    Acta Anaesthesiol Scand; 2021 Feb; 65(2):228-235. PubMed ID: 33037607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Global and regional degree of obstruction determined by electrical impedance tomography in patients with obstructive ventilatory defect.
    Zhang C; Dai M; Liu W; Bai X; Wu J; Xu C; Xia J; Fu F; Shi X; Dong X; Jin F; You F
    PLoS One; 2018; 13(12):e0209473. PubMed ID: 30571739
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of regional pulmonary oxygen uptake--a novel approach using electrical impedance tomography.
    Elke G; Pulletz S; Schädler D; Zick G; Gawelczyk B; Frerichs I; Weiler N
    Physiol Meas; 2011 Jul; 32(7):877-86. PubMed ID: 21646714
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring of regional lung ventilation using electrical impedance tomography after cardiac surgery in infants and children.
    Krause U; Becker K; Hahn G; Dittmar J; Ruschewski W; Paul T
    Pediatr Cardiol; 2014 Aug; 35(6):990-7. PubMed ID: 24569885
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prolonged Continuous Monitoring of Regional Lung Function in Infants with Respiratory Failure.
    Becher TH; Miedema M; Kallio M; Papadouri T; Karaoli C; Sophocleous L; Rahtu M; van Leuteren RW; Waldmann AD; Strodthoff C; Yerworth R; Dupré A; Benissa MR; Nordebo S; Khodadad D; Bayford R; Vliegenthart R; Rimensberger PC; van Kaam AH; Frerichs I
    Ann Am Thorac Soc; 2022 Jun; 19(6):991-999. PubMed ID: 34898392
    [No Abstract]   [Full Text] [Related]  

  • 16. Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma.
    Frerichs I; Zhao Z; Becher T; Zabel P; Weiler N; Vogt B
    Physiol Meas; 2016 Jun; 37(6):698-712. PubMed ID: 27203725
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease.
    Milne S; Huvanandana J; Nguyen C; Duncan JM; Chapman DG; Tonga KO; Zimmermann SC; Slattery A; King GG; Thamrin C
    J Appl Physiol (1985); 2019 Nov; 127(5):1441-1452. PubMed ID: 31556831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Event-triggered averaging of electrical impedance tomography (EIT) respiratory waveforms as compared to low-pass filtering for removal of cardiac related impedance changes.
    Coppadoro A; Eronia N; Foti G; Bellani G
    J Clin Monit Comput; 2020 Jun; 34(3):553-558. PubMed ID: 31278546
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High Frame Rate Electrical Impedance Tomography System for Monitoring of Regional Lung Ventilation.
    Rahal M; Dai J; Wu Y; Bardill A; Bayford R; Demosthenous A
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():2487-2490. PubMed ID: 36085910
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic relative regional strain visualized by electrical impedance tomography in patients suffering from COVID-19.
    Pulletz S; Krukewitt L; Gonzales-Rios P; Teschendorf P; Kremeier P; Waldmann A; Zitzmann A; Müller-Graf F; Acosta C; Tusman G; Reuter DA; Böhm SH
    J Clin Monit Comput; 2022 Aug; 36(4):975-985. PubMed ID: 34386896
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.