These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves. Voigtländer L; Kim WK; Mauri V; Goßling A; Renker M; Sugiura A; Linder M; Schmidt T; Schofer N; Westermann D; Reichenspurner H; Nickenig G; Blankenberg S; Hamm C; Conradi L; Adam M; Sinning JM; Seiffert M Clin Res Cardiol; 2021 Dec; 110(12):1957-1966. PubMed ID: 34387736 [TBL] [Abstract][Full Text] [Related]
6. A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation. Dementhon J; Rioufol G; Obadia JF; Vergnat M; Green L; Croisille P; Boussel L; Peron J; Revel D; Finet G Arch Cardiovasc Dis; 2015 May; 108(5):281-92. PubMed ID: 25863427 [TBL] [Abstract][Full Text] [Related]
7. Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry. Tchetche D; de Biase C; van Gils L; Parma R; Ochala A; Lefevre T; Hovasse T; De Backer O; Sondergaard L; Bleiziffer S; Lange R; Kornowski R; Landes U; Norgaard BL; Biasco L; Philippart R; Molina-Martin de Nicolas J; Mylotte D; Lemee C; Dumonteil N; Van Mieghem NM Circ Cardiovasc Interv; 2019 Jan; 12(1):e007107. PubMed ID: 30626202 [TBL] [Abstract][Full Text] [Related]
8. Paravalvular leak after transcatheter aortic valve implantation: is it anatomically predictable or procedurally determined? MDCT study. Sakrana AA; Nasr MM; Ashamallah GA; Abuelatta RA; Naeim HA; Tahlawi ME Clin Radiol; 2016 Nov; 71(11):1095-103. PubMed ID: 27612848 [TBL] [Abstract][Full Text] [Related]
9. Bicuspid aortic valve sizing for transcatheter aortic valve implantation: Development and validation of an algorithm based on multi-slice computed tomography. Petronio AS; Angelillis M; De Backer O; Giannini C; Costa G; Fiorina C; Castriota F; Bedogni F; Laborde JC; Søndergaard L J Cardiovasc Comput Tomogr; 2020; 14(5):452-461. PubMed ID: 32001214 [TBL] [Abstract][Full Text] [Related]
10. Computed tomography predictors of structural valve degeneration in patients undergoing transcatheter aortic valve implantation with balloon-expandable prostheses. Guglielmo M; Fusini L; Muratori M; Tamborini G; Mantegazza V; Andreini D; Annoni A; Babbaro M; Baggiano A; Conte E; Carriero S; Formenti A; Guaricci AI; Mancini E; Mollace R; Muscogiuri G; Mushtaq S; Ricci F; Rossi A; Scafuri S; Alushi B; Cau C; Cau R; Cesarano M; Saba L; Rabbat M; Pepi M; Pontone G Eur Radiol; 2022 Sep; 32(9):6017-6027. PubMed ID: 35364711 [TBL] [Abstract][Full Text] [Related]
11. Impact of sigmoid septum on periprocedural outcomes following transcatheter aortic valve implantation using current-generation valves. Tsuda M; Egami Y; Matsuhiro Y; Nakamura H; Yasumoto K; Okamoto N; Matsunaga-Lee Y; Yano M; Nishino M; Tanouchi J Int J Cardiovasc Imaging; 2022 Jan; 38(1):171-180. PubMed ID: 34843040 [TBL] [Abstract][Full Text] [Related]
12. Impact of underfilling and overfilling in balloon-expandable transcatheter aortic valve implantation assessed by multidetector computed tomography: Insights from the Optimized CathEter vAlvular iNtervention (OCEAN-TAVI) registry. Yashima F; Yamamoto M; Watanabe Y; Takagi K; Yamada Y; Inohara T; Yanagisawa R; Tanaka M; Arai T; Shimizu H; Jinzaki M; Kozuma K; Fukuda K; Suzuki T; Hayashida K Int J Cardiol; 2016 Nov; 222():738-744. PubMed ID: 27521550 [TBL] [Abstract][Full Text] [Related]
13. Previously implanted mitral surgical prosthesis in patients undergoing transcatheter aortic valve implantation: Procedural outcome and morphologic assessment using multidetector computed tomography. Tanaka M; Yanagisawa R; Yashima F; Arai T; Jinzaki M; Shimizu H; Fukuda K; Watanabe Y; Naganuma T; Shirai S; Araki M; Tada N; Yamanaka F; Higashimori A; Takagi K; Ueno H; Tabata M; Mizutani K; Yamamoto M; Hayashida K; PLoS One; 2019; 14(12):e0226512. PubMed ID: 31877159 [TBL] [Abstract][Full Text] [Related]
14. Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography. Husser O; Holzamer A; Resch M; Endemann DH; Nunez J; Bodi V; Schmid C; Riegger GA; Gössmann H; Hamer O; Stroszczynski C; Luchner A; Hilker M; Hengstenberg C Int J Cardiol; 2013 Oct; 168(4):3431-8. PubMed ID: 23688431 [TBL] [Abstract][Full Text] [Related]
16. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation. Rixe J; Schuhbaeck A; Liebetrau C; Moellmann H; Nef HM; Szardien S; Brandt R; Schmitt J; Neumann T; Schneider C; Krombach G; Hamm CW; Achenbach S; Rolf A Eur Radiol; 2012 Dec; 22(12):2662-9. PubMed ID: 22688129 [TBL] [Abstract][Full Text] [Related]
17. Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Lehmkuhl L; Foldyna B; Von Aspern K; Lücke C; Grothoff M; Nitzsche S; Kempfert J; Haensig M; Rastan A; Walther T; Mohr FW; Gutberlet M Int J Cardiovasc Imaging; 2013 Mar; 29(3):693-703. PubMed ID: 22986896 [TBL] [Abstract][Full Text] [Related]
18. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study. Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972 [TBL] [Abstract][Full Text] [Related]
19. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography. Pontone G; Andreini D; Bartorelli AL; Bertella E; Cortinovis S; Mushtaq S; Annoni A; Formenti A; Baggiano A; Conte E; Tamborini G; Muratori M; Gripari P; Bovis F; Veglia F; Foti C; Alamanni F; Ballerini G; Fiorentini C; Pepi M Am Heart J; 2012 Oct; 164(4):576-84. PubMed ID: 23067917 [TBL] [Abstract][Full Text] [Related]
20. Transcatheter Aortic Valve Replacement in Patients With a Small Annulus - From the Japanese Nationwide Registry (J-TVT). Meguro K; Kumamaru H; Kohsaka S; Hashimoto T; Kakizaki R; Kitamura T; Shimizu H; Ako J Circ J; 2021 Jun; 85(7):967-976. PubMed ID: 33642425 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]