These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 36501691)

  • 41. Biodegradable poly(lactide-co-glycolide) coatings on magnesium alloys for orthopedic applications.
    Ostrowski NJ; Lee B; Roy A; Ramanathan M; Kumta PN
    J Mater Sci Mater Med; 2013 Jan; 24(1):85-96. PubMed ID: 23053803
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31.
    Gray-Munro JE; Seguin C; Strong M
    J Biomed Mater Res A; 2009 Oct; 91(1):221-30. PubMed ID: 18814220
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Biosensitive and antibacterial coatings on metallic material for medical applications.
    Goldmann WH
    Cell Biol Int; 2021 Aug; 45(8):1624-1632. PubMed ID: 33818836
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Biomedical Alloys and Physical Surface Modifications: A Mini-Review.
    Yan X; Cao W; Li H
    Materials (Basel); 2021 Dec; 15(1):. PubMed ID: 35009212
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Surface treatments for controlling corrosion rate of biodegradable Mg and Mg-based alloy implants.
    Uddin MS; Hall C; Murphy P
    Sci Technol Adv Mater; 2015 Oct; 16(5):053501. PubMed ID: 27877829
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Anticorrosive Self-Assembled Hybrid Alkylsilane Coatings for Resorbable Magnesium Metal Devices.
    Patil AJ; Jackson O; Fulton LB; Hong D; Desai PA; Kelleher SA; Chou DT; Tan S; Kumta PN; Beniash E
    ACS Biomater Sci Eng; 2017 Apr; 3(4):518-529. PubMed ID: 33429619
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Topologically ordered magnesium-biopolymer hybrid composite structures.
    Oosterbeek RN; Seal CK; Staiger MP; Hyland MM
    J Biomed Mater Res A; 2015 Jan; 103(1):311-7. PubMed ID: 24659540
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Sputtered Si and Mg doped hydroxyapatite for biomedical applications.
    Vladescu A; Mihai Cotrut C; Ak Azem F; Bramowicz M; Pana I; Braic V; Birlik I; Kiss A; Braic M; Abdulgader R; Booysen R; Kulesza S; Monsees TK
    Biomed Mater; 2018 Jan; 13(2):025011. PubMed ID: 29381477
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Surface modifications of magnesium alloys for biomedical applications.
    Yang J; Cui F; Lee IS
    Ann Biomed Eng; 2011 Jul; 39(7):1857-71. PubMed ID: 21445692
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Preparation and properties of composite MAO/ECD coatings on magnesium alloy.
    Zhao Q; Guo X; Dang X; Hao J; Lai J; Wang K
    Colloids Surf B Biointerfaces; 2013 Feb; 102():321-6. PubMed ID: 23018022
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Corrosion Resistance and Cytocompatibility of Magnesium-Calcium Alloys Modified with Zinc- or Gallium-Doped Calcium Phosphate Coatings.
    Tamay DG; Gokyer S; Schmidt J; Vladescu A; Yilgor Huri P; Hasirci V; Hasirci N
    ACS Appl Mater Interfaces; 2022 Jan; 14(1):104-122. PubMed ID: 34958199
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The effect of hybrid coatings based on hydrogel, biopolymer and inorganic components on the corrosion behavior of titanium bone implants.
    Saveleva M; Vladescu A; Cotrut C; Van der Meeren L; Surmeneva M; Surmenev R; Parakhonskiy B; Skirtach AG
    J Mater Chem B; 2019 Nov; 7(43):6778-6788. PubMed ID: 31595943
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of endothelial cell attachment on surfaces of biodegradable polymer-coated magnesium alloys in a microfluidic environment.
    Liu L; Ye SH; Gu X; Russell T; Xu Z; Sankar J; Wagner WR; Lee YC; Yun Y
    PLoS One; 2018; 13(10):e0205611. PubMed ID: 30304058
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Bi-layered silane-TiO
    Córdoba LC; Hélary C; Montemor F; Coradin T
    Mater Sci Eng C Mater Biol Appl; 2019 Jan; 94():126-138. PubMed ID: 30423694
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Progress in Niobium Oxide-Containing Coatings for Biomedical Applications: A Critical Review.
    Safavi MS; Walsh FC; Visai L; Khalil-Allafi J
    ACS Omega; 2022 Mar; 7(11):9088-9107. PubMed ID: 35356687
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Porous magnesium-based scaffolds for tissue engineering.
    Yazdimamaghani M; Razavi M; Vashaee D; Moharamzadeh K; Boccaccini AR; Tayebi L
    Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():1253-1266. PubMed ID: 27987682
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Bioactive glass coatings on metallic implants for biomedical applications.
    Oliver JN; Su Y; Lu X; Kuo PH; Du J; Zhu D
    Bioact Mater; 2019 Dec; 4():261-270. PubMed ID: 31667443
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Improving the corrosion behavior of magnesium alloys with a focus on AZ91 Mg alloy intended for biomedical application by microstructure modification and coating.
    Akbarzadeh FZ; Ghomi ER; Ramakrishna S
    Proc Inst Mech Eng H; 2022 Aug; 236(8):1188-1208. PubMed ID: 35735119
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Corrosion resistance of a composite polymeric coating applied on biodegradable AZ31 magnesium alloy.
    Zomorodian A; Garcia MP; Moura e Silva T; Fernandes JC; Fernandes MH; Montemor MF
    Acta Biomater; 2013 Nov; 9(10):8660-70. PubMed ID: 23454214
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Recent Progress in Functionalized Coatings for Corrosion Protection of Magnesium Alloys-A Review.
    Li B; Zhang Z; Liu T; Qiu Z; Su Y; Zhang J; Lin C; Wang L
    Materials (Basel); 2022 May; 15(11):. PubMed ID: 35683210
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.