BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36507958)

  • 1. Development of an improved standard reference material for folate vitamers in human serum.
    Camara JE; Pritchett JS; Daniels YC; Bedner M; Nelson MA; Lowenthal MS; Fazili Z; Pfeiffer CM; Phinney KW; Sharpless KE; Sander LC; Lippa KA; Yen JH; Kuszak AJ; Wise SA
    Anal Bioanal Chem; 2023 Feb; 415(5):809-821. PubMed ID: 36507958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of fortified and endogenous folates in food-based Standard Reference Materials by liquid chromatography-tandem mass spectrometry.
    Camara JE; Lowenthal MS; Phinney KW
    Anal Bioanal Chem; 2013 May; 405(13):4561-8. PubMed ID: 23354578
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Origins of the difference between food folate analysis results obtained by LC-MS/MS and microbiological assays.
    Ringling C; Rychlik M
    Anal Bioanal Chem; 2017 Mar; 409(7):1815-1825. PubMed ID: 28050625
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a new standard reference material: SRM 1955 (homocysteine and folate in human serum).
    Satterfield MB; Sniegoski LT; Sharpless KE; Welch MJ; Hornikova A; Zhang NF; Pfeiffer CM; Fazili Z; Zhang M; Nelson BC
    Anal Bioanal Chem; 2006 Jun; 385(3):612-22. PubMed ID: 16715281
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Commutability of NIST SRM 1955 Homocysteine and Folate in Frozen Human Serum with selected total homocysteine immunoassays and enzymatic assays.
    Nelson BC; Pfeiffer CM; Zhang M; Duewer DL; Sharpless KE; Lippa KA
    Clin Chim Acta; 2008 Sep; 395(1-2):99-105. PubMed ID: 18565331
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The establishment of LC-MS/MS assays-specific reference intervals for serum folates and its application in evaluating FA-supplemented folate deficiency patients: Appeals for a suitable and individualized supplementation.
    Liu Z; Jin L; Zhang J; Zhou W; Zeng J; Zhang T; Zhang C
    Clin Chim Acta; 2022 Dec; 537():96-104. PubMed ID: 36261072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitation of whole-blood total folate within defined MTHFR C677T genotype groups by isotope dilution-liquid chromatography-tandem mass spectrometry differs from microbiologic assay.
    Stamm RA; Harper MJ; Houghton LA
    J Nutr; 2012 Dec; 142(12):2154-60. PubMed ID: 23096011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two International Round-Robin Studies Showed Good Comparability of 5-Methyltetrahydrofolate but Poor Comparability of Folic Acid Measured in Serum by Different High-Performance Liquid Chromatography-Tandem Mass Spectrometry Methods.
    Fazili Z; Sternberg MR; Paladugula N; Pfeiffer CM
    J Nutr; 2017 Sep; 147(9):1815-1825. PubMed ID: 28768831
    [No Abstract]   [Full Text] [Related]  

  • 9. Accounting for an isobaric interference allows correct determination of folate vitamers in serum by isotope dilution-liquid chromatography-tandem MS.
    Fazili Z; Pfeiffer CM
    J Nutr; 2013 Jan; 143(1):108-13. PubMed ID: 23173171
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Water-soluble vitamins.
    Konings EJ;
    J AOAC Int; 2006; 89(1):285-8. PubMed ID: 16512258
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Folate status and concentrations of serum folate forms in the US population: National Health and Nutrition Examination Survey 2011-2.
    Pfeiffer CM; Sternberg MR; Fazili Z; Lacher DA; Zhang M; Johnson CL; Hamner HC; Bailey RL; Rader JI; Yamini S; Berry RJ; Yetley EA
    Br J Nutr; 2015 Jun; 113(12):1965-77. PubMed ID: 25917925
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.
    Lowenthal MS; Yen J; Bunk DM; Phinney KW
    Anal Bioanal Chem; 2010 May; 397(2):511-9. PubMed ID: 20238103
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantification of polyglutamyl 5-methyltetrahydrofolate, monoglutamyl folate vitamers, and total folates in different berries and berry juice by UHPLC-MS/MS.
    Zou Y; Duan H; Li L; Chen X; Wang C
    Food Chem; 2019 Mar; 276():1-8. PubMed ID: 30409571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A high-throughput LC-MS/MS method suitable for population biomonitoring measures five serum folate vitamers and one oxidation product.
    Fazili Z; Whitehead RD; Paladugula N; Pfeiffer CM
    Anal Bioanal Chem; 2013 May; 405(13):4549-60. PubMed ID: 23462981
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Isotope dilution-LC-MS/MS reference method assessment of serum folate assay accuracy and proficiency testing consensus mean.
    Blackmore S; Pfeiffer CM; Lee A; Fazili Z; Hamilton MS
    Clin Chem; 2011 Jul; 57(7):986-94. PubMed ID: 21561849
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The loss of 5-methyltetrahydrofolate in human serum under suboptimal preanalytical conditions can only partially be recovered by an oxidation product.
    Fazili Z; Sternberg MR; Paladugula N; Whitehead RD; Chen H; Pfeiffer CM
    J Nutr; 2014 Nov; 144(11):1873-9. PubMed ID: 25332487
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Liquid chromatography-tandem mass spectrometry analysis of folate and folate catabolites in human serum.
    Hannisdal R; Ueland PM; Svardal A
    Clin Chem; 2009 Jun; 55(6):1147-54. PubMed ID: 19359539
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomarkers of folate status in NHANES: a roundtable summary.
    Yetley EA; Pfeiffer CM; Phinney KW; Fazili Z; Lacher DA; Bailey RL; Blackmore S; Bock JL; Brody LC; Carmel R; Curtin LR; Durazo-Arvizu RA; Eckfeldt JH; Green R; Gregory JF; Hoofnagle AN; Jacobsen DW; Jacques PF; Molloy AM; Massaro J; Mills JL; Nexo E; Rader JI; Selhub J; Sempos C; Shane B; Stabler S; Stover P; Tamura T; Tedstone A; Thorpe SJ; Coates PM; Johnson CL; Picciano MF
    Am J Clin Nutr; 2011 Jul; 94(1):303S-312S. PubMed ID: 21593502
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous quantification of homocysteine and folate in human serum or plasma using liquid chromatography/tandem mass spectrometry.
    Nelson BC; Satterfield MB; Sniegoski LT; Welch MJ
    Anal Chem; 2005 Jun; 77(11):3586-93. PubMed ID: 15924393
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the sensitive determination of folates in rice.
    De Brouwer V; Storozhenko S; Stove CP; Van Daele J; Van der Straeten D; Lambert WE
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Feb; 878(3-4):509-13. PubMed ID: 20061193
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.