These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 36508489)

  • 41. Biomechanical stability of intramedullary nailed high proximal third tibial fractures with cement augmented proximal screws.
    Roth SE; Kreder H; Stephen D; Whyne CM
    J Orthop Trauma; 2005 Aug; 19(7):457-61. PubMed ID: 16056077
    [TBL] [Abstract][Full Text] [Related]  

  • 42. LISS PLT: design, mechanical and biomechanical characteristics.
    Goesling T; Frenk A; Appenzeller A; Garapati R; Marti A; Krettek C
    Injury; 2003 Aug; 34 Suppl 1():A11-5. PubMed ID: 14563006
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The primary stability of angle-stable versus conventional locked intramedullary nails.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    Int Orthop; 2012 May; 36(5):1059-64. PubMed ID: 22127384
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Fracture site motion with Ilizarov and "hybrid" external fixation.
    Khalily C; Voor MJ; Seligson D
    J Orthop Trauma; 1998 Jan; 12(1):21-6. PubMed ID: 9447515
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The stiffness characteristics of hybrid Ilizarov fixators.
    Baran O; Havitcioglu H; Tatari H; Cecen B
    J Biomech; 2008 Oct; 41(14):2960-3. PubMed ID: 18789446
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A novel way to dynamize a spatial frame and optimize fracture healing.
    Iobst CA; Milne E; Khoury A; Ingwer Z; Latta L
    Injury; 2021 Jan; 52(1):106-108. PubMed ID: 33039178
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Transfixion wire positioning within the bone: an option to control proximal tibia external fixation stiffness.
    Antoci V; Raney EM; Antoci V; Voor MJ; Roberts CS
    J Pediatr Orthop; 2006; 26(4):466-70. PubMed ID: 16791063
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The hybrid ring tubular external fixator: a biomechanical study.
    Stein H; Mosheiff R; Baumgart F; Frigg R; Perren SM; Cordey J
    Clin Biomech (Bristol, Avon); 1997 Jun; 12(4):259-266. PubMed ID: 11415731
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Mechanical stress on tensioned wires at direct and indirect loading: a biomechanical study on the Ilizarov external fixator.
    Gessmann J; Jettkant B; Schildhauer TA; Seybold D
    Injury; 2011 Oct; 42(10):1107-11. PubMed ID: 21392761
    [TBL] [Abstract][Full Text] [Related]  

  • 51. In vitro effects of external fixation on intact and osteotomized tibiae. A biomechanical study.
    Terjesen T; Benum P
    Acta Orthop Scand; 1983 Apr; 54(2):212-9. PubMed ID: 6845997
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparison of mechanical performance among different frame configurations of the Ilizarov external fixator: experimental study.
    Sarpel Y; Gulsen M; Togrul E; Capa M; Herdem M
    J Trauma; 2005 Mar; 58(3):546-52. PubMed ID: 15761350
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Experimental model for controlling shear using the Ilizarov frame.
    Jabbar Y; Khaleel A
    Clin Biomech (Bristol, Avon); 2015 Nov; 30(9):995-1001. PubMed ID: 26194448
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Hybrid external fixation of the proximal tibia: strategies to improve frame stability.
    Roberts CS; Dodds JC; Perry K; Beck D; Seligson D; Voor MJ
    J Orthop Trauma; 2003 Jul; 17(6):415-20. PubMed ID: 12843726
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
    Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
    Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The biomechanics of hybrid external fixation.
    Pugh KJ; Wolinsky PR; Dawson JM; Stahlman GC
    J Orthop Trauma; 1999 Jan; 13(1):20-6. PubMed ID: 9892121
    [TBL] [Abstract][Full Text] [Related]  

  • 57. An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae.
    McDuffee LA; Stover SM; Taylor KT
    Vet Surg; 1997; 26(2):126-36. PubMed ID: 9068163
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures.
    Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P
    Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.
    Lowenberg DW; DeBaun MR; Behn A; Sox-Harris A
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1205-1213. PubMed ID: 32367222
    [TBL] [Abstract][Full Text] [Related]  

  • 60. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
    Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
    J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.