283 related articles for article (PubMed ID: 36516054)

  • 1. Multicenter Randomized Trial of Intermittently Scanned Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose in Individuals With Type 2 Diabetes and Recent-Onset Acute Myocardial Infarction: Results of the LIBERATES Trial.
    Ajjan RA; Heller SR; Everett CC; Vargas-Palacios A; Higham R; Sharples L; Gorog DA; Rogers A; Reynolds C; Fernandez C; Rodrigues P; Sathyapalan T; Storey RF; Stocken DD
    Diabetes Care; 2023 Feb; 46(2):441-449. PubMed ID: 36516054
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficacy and Safety of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring in Patients With Type 2 Diabetes: A Systematic Review and Meta-analysis of Interventional Evidence.
    Seidu S; Kunutsor SK; Ajjan RA; Choudhary P
    Diabetes Care; 2024 Jan; 47(1):169-179. PubMed ID: 38117991
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Addition of intermittently scanned continuous glucose monitoring to standard care in a cohort of pregnant women with type 1 diabetes: effect on glycaemic control and pregnancy outcomes.
    Perea V; Picón MJ; Megia A; Goya M; Wägner AM; Vega B; Seguí N; Montañez MD; Vinagre I
    Diabetologia; 2022 Aug; 65(8):1302-1314. PubMed ID: 35546211
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intermittently scanned continuous glucose monitoring in adults with type 1 diabetes: A subgroup analysis from the FLASH-UK study.
    Leelarathna L; Sutton CJ; Evans ML; Neupane S; Rayman G; Lumley S; Cranston I; Narendran P; Krishan A; Taxiarchi VP; Barnard-Kelly K; Elliott RA; Burns M; Camm M; Thabit H; Wilmot EG;
    Diabet Med; 2024 Mar; 41(3):e15249. PubMed ID: 37897112
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of 6 Months of Flash Glucose Monitoring in Youth With Type 1 Diabetes and High-Risk Glycemic Control: A Randomized Controlled Trial.
    Boucher SE; Gray AR; Wiltshire EJ; de Bock MI; Galland BC; Tomlinson PA; Rayns JA; MacKenzie KE; Chan H; Rose S; Wheeler BJ
    Diabetes Care; 2020 Oct; 43(10):2388-2395. PubMed ID: 32788281
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lower Glycated Hemoglobin with Real-Time Continuous Glucose Monitoring Than with Intermittently Scanned Continuous Glucose Monitoring After 1 Year: The CORRIDA LIFE Study.
    Radovnická L; Hásková A; Do QD; Horová E; Navrátilová V; Mikeš O; Cihlář D; Parkin CG; Grunberger G; Prázný M; Šoupal J
    Diabetes Technol Ther; 2022 Dec; 24(12):859-867. PubMed ID: 36037056
    [No Abstract]   [Full Text] [Related]  

  • 7. Effects of 12-Week Freestyle Libre 2.0 in Children with Type 1 Diabetes and Elevated HbA1c: A Multicenter Randomized Controlled Trial.
    Jefferies CA; Boucsein A; Styles SE; Chamberlain B; Michaels VR; Crockett HR; De Lange M; Lala A; Cunningham V; Wiltshire EJ; Serlachius AS; Wheeler BJ
    Diabetes Technol Ther; 2023 Dec; 25(12):827-835. PubMed ID: 37782139
    [No Abstract]   [Full Text] [Related]  

  • 8. Intermittently scanned continuous glucose monitoring provides no benefit over structured self-monitoring of blood glucose in type 2 diabetes not on prandial insulin, in the context of diabetes self-management education: GLucose monitoring programme SingaporE (GLiMPSE).
    Rama Chandran S; Rahman N; Gandhi M; Tan NC; Phoon IKY; Seah DEJ; Cheah MH; Sek K; Gardner DS
    Diabetes Res Clin Pract; 2024 May; 211():111678. PubMed ID: 38642860
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of intermittently scanned continuous glucose monitoring in young people with high-risk type 1 diabetes-Extension phase outcomes following a 6-month randomized control trial.
    Rose S; Styles SE; Wiltshire EJ; Stanley J; Galland BC; de Bock MI; Tomlinson PA; Rayns JA; MacKenzie KE; Wheeler BJ
    Diabet Med; 2022 May; 39(5):e14756. PubMed ID: 34862661
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial.
    Hásková A; Radovnická L; Petruželková L; Parkin CG; Grunberger G; Horová E; Navrátilová V; Kádě O; Matoulek M; Prázný M; Šoupal J
    Diabetes Care; 2020 Nov; 43(11):2744-2750. PubMed ID: 32859607
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimating the cost-effectiveness of intermittently scanned continuous glucose monitoring in adults with type 1 diabetes in England.
    Elliott RA; Rogers G; Evans ML; Neupane S; Rayman G; Lumley S; Cranston I; Narendran P; Sutton CJ; Taxiarchi VP; Burns M; Thabit H; Wilmot EG; Leelarathna L;
    Diabet Med; 2024 Mar; 41(3):e15232. PubMed ID: 37750427
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial.
    Visser MM; Charleer S; Fieuws S; De Block C; Hilbrands R; Van Huffel L; Maes T; Vanhaverbeke G; Dirinck E; Myngheer N; Vercammen C; Nobels F; Keymeulen B; Mathieu C; Gillard P
    Lancet; 2021 Jun; 397(10291):2275-2283. PubMed ID: 34089660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-adjunctive flash glucose monitoring system use during summer-camp in children with type 1 diabetes: The free-summer study.
    Piona C; Dovc K; Mutlu GY; Grad K; Gregorc P; Battelino T; Bratina N
    Pediatr Diabetes; 2018 Nov; 19(7):1285-1293. PubMed ID: 30022571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes.
    Nørgaard SK; Mathiesen ER; Nørgaard K; Ringholm L
    Diabetes Technol Ther; 2021 Oct; 23(10):665-672. PubMed ID: 34086494
    [No Abstract]   [Full Text] [Related]  

  • 15. Effect of switching from intermittently scanned to real-time continuous glucose monitoring in adults with type 1 diabetes: 24-month results from the randomised ALERTT1 trial.
    Visser MM; Charleer S; Fieuws S; De Block C; Hilbrands R; Van Huffel L; Maes T; Vanhaverbeke G; Dirinck E; Myngheer N; Vercammen C; Nobels F; Keymeulen B; Mathieu C; Gillard P
    Lancet Diabetes Endocrinol; 2023 Feb; 11(2):96-108. PubMed ID: 36702566
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flash glucose monitoring and automated bolus calculation in type 1 diabetes treated with multiple daily insulin injections: a 26 week randomised, controlled, multicentre trial.
    Secher AL; Pedersen-Bjergaard U; Svendsen OL; Gade-Rasmussen B; Almdal T; Raimond L; Vistisen D; Nørgaard K
    Diabetologia; 2021 Dec; 64(12):2713-2724. PubMed ID: 34495375
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intermittently scanned continuous glucose monitoring is associated with high satisfaction but increased HbA1c and weight in well-controlled youth with type 1 diabetes.
    Charleer S; Gillard P; Vandoorne E; Cammaerts K; Mathieu C; Casteels K
    Pediatr Diabetes; 2020 Dec; 21(8):1465-1474. PubMed ID: 32981187
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparing the glycaemic outcomes between real-time continuous glucose monitoring (rt-CGM) and intermittently scanned continuous glucose monitoring (isCGM) among adults and children with type 1 diabetes: A systematic review and meta-analysis of randomized controlled trials.
    Zhou Y; Sardana D; Kuroko S; Haszard JJ; de Block MI; Weng J; Jefferies C; Wheeler BJ
    Diabet Med; 2024 Mar; 41(3):e15280. PubMed ID: 38197238
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of intermittently scanned continuous glucose monitoring in adult type 1 diabetes patients with suboptimal glycaemic control: A multi-centre randomized controlled trial.
    Yan J; Zhou Y; Zheng X; Zheng M; Lu J; Luo S; Yang D; Deng H; Xu W; Bi Y; Bao W; Weng J
    Diabetes Metab Res Rev; 2023 May; 39(4):e3614. PubMed ID: 36670050
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of Intermittently Scanned Continuous Glucose Monitoring in the Prevention of Recurrent Severe Hypoglycemia.
    Davis TME; Dwyer P; England M; Fegan PG; Davis WA
    Diabetes Technol Ther; 2020 May; 22(5):367-373. PubMed ID: 31724878
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 15.