BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 36516201)

  • 21. Continuous CD34+ cell collection by a new device is safe and more efficient than by a standard collection procedure: results of a two-center, crossover, randomized trial.
    Cancelas JA; Scott EP; Bill JR
    Transfusion; 2016 Nov; 56(11):2824-2832. PubMed ID: 27589225
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Autologous lymphapheresis for the production of chimeric antigen receptor T cells.
    Allen ES; Stroncek DF; Ren J; Eder AF; West KA; Fry TJ; Lee DW; Mackall CL; Conry-Cantilena C
    Transfusion; 2017 May; 57(5):1133-1141. PubMed ID: 28236305
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Advantages of high cell concentration prior to cryopreservation of initial leukapheresis in CAR-T cell therapy.
    Carbonell D; Monsalvo S; Catalá E; Pérez-Corral A; Villegas C; Falero C; Ruano G; Martinez M; Kwon M; Muñoz-Martínez C; Díez-Martín JL; Gayoso J; Anguita J
    Blood Transfus; 2024 May; 22(3):239-245. PubMed ID: 38063787
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of peripheral blood mononuclear cell collection by leukapheresis.
    Chen J; Goss C; Avecilla ST; Hong H; Walsh E; Wuest D; Maslak P; Pessin MS
    Transfusion; 2019 May; 59(5):1765-1772. PubMed ID: 30747437
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Factors Influencing Mononuclear Cell Collection in Tumor Cell Biotherapy].
    Jiang Y; Li LL; Chi HX; Qiu XD; Yao H; Tian J; Lin J; Zhang LY; Liu XM; Yu Y; Wang DQ
    Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2020 Apr; 28(2):622-628. PubMed ID: 32319406
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Unstimulated leukapheresis in patients and donors: comparison of two apheresis systems.
    Schulz M; Bialleck H; Thorausch K; Bug G; Dünzinger U; Seifried E; Bönig H
    Transfusion; 2014 Jun; 54(6):1622-9. PubMed ID: 24299303
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study.
    Ikeda K; Minakawa K; Muroi K; Fujiwara SI; Yamada-Fujiwara M; Fujimori Y; Tanosaki R; Ohto H;
    Transfusion; 2016 Nov; 56(11):2839-2847. PubMed ID: 27572290
    [TBL] [Abstract][Full Text] [Related]  

  • 28. PBPC collection techniques: standard versus large volume leukapheresis (LVL) in donors and in patients.
    Gasová Z; Marinov I; Vodvárková S; Böhmová M; Bhuyian-Ludvíková Z
    Transfus Apher Sci; 2005 Apr; 32(2):167-76. PubMed ID: 15784451
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimizing autologous nonmobilized mononuclear cell collections for cellular therapy in pediatric patients with high-risk leukemia.
    Even-Or E; Di Mola M; Ali M; Courtney S; McDougall E; Alexander S; Schechter T; Whitlock JA; Licht C; Krueger J
    Transfusion; 2017 Jun; 57(6):1536-1542. PubMed ID: 28439898
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Collection efficiency and safety of large-volume leukapheresis for the manufacturing of tisagenlecleucel.
    Kitamura W; Urata T; Fujii K; Fukumi T; Ikeuchi K; Seike K; Fujiwara H; Asada N; Ennishi D; Matsuoka KI; Otsuka F; Maeda Y; Fujii N
    Transfusion; 2024 Apr; 64(4):674-684. PubMed ID: 38419458
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Lack of defined apheresis collection criteria in publicly available CAR-T cell clinical trial descriptions: Comprehensive review of over 600 studies.
    Thibodeaux SR; Aqui NA; Park YA; Schneiderman J; Su LL; Winters JL; Zubair AC; Schwartz J; Liu HD;
    J Clin Apher; 2022 Jun; 37(3):223-236. PubMed ID: 35085413
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of the CMNC and MNC apheresis protocol for the collection of T-cells showed comparable outcome: An observational study in a single centre.
    Putensen D; Smith R; Pilcher L; Trandafir G
    J Clin Apher; 2018 Jun; 33(3):349-356. PubMed ID: 29465755
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Leukapheresis guidance and best practices for optimal chimeric antigen receptor T-cell manufacturing.
    Qayed M; McGuirk JP; Myers GD; Parameswaran V; Waller EK; Holman P; Rodrigues M; Clough LF; Willert J
    Cytotherapy; 2022 Sep; 24(9):869-878. PubMed ID: 35718701
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Retrospective comparison between COBE SPECTRA and SPECTRA OPTIA apheresis systems for hematopoietic progenitor cells collection for autologous and allogeneic transplantation in a single center.
    López-Pereira P; Sola Aparicio E; Vicuña Andrés I; Cámara Montejano C; Muñoz Calleja C; Alegre Amor A; Aguado Bueno B
    J Clin Apher; 2020 Sep; 35(5):453-459. PubMed ID: 32798328
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of Amicus and COBE Spectra for allogenic peripheral blood stem cell harvest: Study from tertiary care centre in India.
    Setia RD; Arora S; Handoo A; Dadu T; Choudhary D; Sharma SK; Kharya G; Khandelwal V; Sachdeva P; Doval D; Bakliwal A; Kapoor M; Bajaj S; Bachchas V; Singh P
    Transfus Apher Sci; 2017 Jun; 56(3):439-444. PubMed ID: 28528807
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of the new continuous mononuclear cell collection protocol versus an older version on two different apheresis machines.
    Spoerl S; Wäscher D; Nagel S; Peschel C; Verbeek M; Götze K; Krackhardt AM
    Transfusion; 2018 Jul; 58(7):1772-1780. PubMed ID: 29732573
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Analysis of the efficiency and influence factors of PBSC collection with AutoPBSC and MNC procedure of cell separator].
    Zeng F; Wei SJ; Huang HB; Huang QH; Lin QY; Fan LP; Huang HW; Fu DH
    Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2014 Dec; 22(6):1684-90. PubMed ID: 25543497
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Manufacturing chimeric antigen receptor T cells from cryopreserved peripheral blood cells: time for a collect-and-freeze model?
    Palen K; Zurko J; Johnson BD; Hari P; Shah NN
    Cytotherapy; 2021 Nov; 23(11):985-990. PubMed ID: 34538575
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A new protocol for improving efficiency of autologous peripheral blood stem cell collection in patients with high white blood cell counts.
    Boehlen R; Fernandez P; Bargetzi M; Sigle JP
    J Clin Apher; 2020 Jun; 35(3):217-223. PubMed ID: 32304598
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optimization of lymphapheresis for manufacturing autologous CAR-T cells.
    Yamanaka I; Yamauchi T; Henzan T; Sakoda T; Miyamoto K; Mishima H; Ono H; Koga Y; Nakashima Y; Kato K; Miyamoto T; Mizuno S; Ogawa Y; Ohga S; Akashi K; Maeda T; Kunisaki Y
    Int J Hematol; 2021 Oct; 114(4):449-458. PubMed ID: 34275066
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.