These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 36517859)

  • 41. Analysis of cerebrospinal fluid flow waveforms with gated phase-contrast MR velocity measurements.
    Bhadelia RA; Bogdan AR; Wolpert SM
    AJNR Am J Neuroradiol; 1995 Feb; 16(2):389-400. PubMed ID: 7726089
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [The role of arterial, venous blood and cerebrospinal fluid flow disturbances in forming cognitive impairment types in age-related cerebral microangiophathy].
    Dobrynina LA; Gadzhieva ZS; Akhmetzyanov BM; Kalashnikova LA; Krotenkova MV
    Zh Nevrol Psikhiatr Im S S Korsakova; 2019; 119(12. Vyp. 2):81-88. PubMed ID: 32207722
    [TBL] [Abstract][Full Text] [Related]  

  • 43. OFx: A method of 4D image construction from free-breathing non-gated MRI slice acquisitions of the thorax via optical flux.
    Hao Y; Udupa JK; Tong Y; Wu C; Li H; McDonough JM; Lott C; Qiu C; Galagedera N; Anari JB; Torigian DA; Cahill PJ
    Med Image Anal; 2021 Aug; 72():102088. PubMed ID: 34052519
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precession.
    McCormack EJ; Egnor MR; Wagshul ME
    Magn Reson Imaging; 2007 Feb; 25(2):172-82. PubMed ID: 17275611
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Respiratory Effects on Fontan Circulation During Rest and Exercise Using Real-Time Cardiac Magnetic Resonance Imaging.
    Wei Z; Whitehead KK; Khiabani RH; Tree M; Tang E; Paridon SM; Fogel MA; Yoganathan AP
    Ann Thorac Surg; 2016 May; 101(5):1818-25. PubMed ID: 26872728
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Interaction between respiration and right versus left ventricular volumes at rest and during exercise: a real-time cardiac magnetic resonance study.
    Claessen G; Claus P; Delcroix M; Bogaert J; La Gerche A; Heidbuchel H
    Am J Physiol Heart Circ Physiol; 2014 Mar; 306(6):H816-24. PubMed ID: 24464754
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Cerebrospinal Fluid Dynamics in Patients with Multiple Sclerosis: The Role of Phase-Contrast MRI in the Differential Diagnosis of Active and Chronic Disease.
    Öner S; Kahraman AS; Özcan C; Özdemir ZM; Ünlü S; Kamışlı Ö; Öner Z
    Korean J Radiol; 2018; 19(1):72-78. PubMed ID: 29354002
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Respiratory motion corrected 4D flow using golden radial phase encoding.
    Kolbitsch C; Bastkowski R; Schäffter T; Prieto Vasquez C; Weiss K; Maintz D; Giese D
    Magn Reson Med; 2020 Feb; 83(2):635-644. PubMed ID: 31464355
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects.
    Maier IL; Hofer S; Joseph AA; Merboldt KD; Tan Z; Schregel K; Knauth M; Bähr M; Psychogios MN; Liman J; Frahm J
    Eur J Radiol; 2018 Sep; 106():38-45. PubMed ID: 30150049
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Phase contrast MRI quantification of pulsatile volumes of brain arteries, veins, and cerebrospinal fluids compartments: repeatability and physiological interactions.
    Wåhlin A; Ambarki K; Hauksson J; Birgander R; Malm J; Eklund A
    J Magn Reson Imaging; 2012 May; 35(5):1055-62. PubMed ID: 22170792
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Concomitant analysis of arterial, venous, and CSF flows using phase-contrast MRI: a quantitative comparison between MS patients and healthy controls.
    ElSankari S; Balédent O; van Pesch V; Sindic C; de Broqueville Q; Duprez T
    J Cereb Blood Flow Metab; 2013 Sep; 33(9):1314-21. PubMed ID: 23778162
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Slow rhythmic oscillations in intracranial CSF and blood flow: registered by MRI.
    Strik C; Klose U; Kiefer C; Grodd W
    Acta Neurochir Suppl; 2002; 81():139-42. PubMed ID: 12168286
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Upright versus supine MRI: effects of body position on craniocervical CSF flow.
    Muccio M; Chu D; Minkoff L; Kulkarni N; Damadian B; Damadian RV; Ge Y
    Fluids Barriers CNS; 2021 Dec; 18(1):61. PubMed ID: 34952607
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Cerebrospinal Fluid Flow Studies and Recent Advancements.
    Kelly EJ; Yamada S
    Semin Ultrasound CT MR; 2016 Apr; 37(2):92-9. PubMed ID: 27063659
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Phase-contrast MR studies of CSF flow rate in the cerebral aqueduct and cervical subarachnoid space with correlation-based segmentation.
    Yoshida K; Takahashi H; Saijo M; Ueguchi T; Tanaka H; Fujita N; Murase K
    Magn Reson Med Sci; 2009; 8(3):91-100. PubMed ID: 19783872
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Cerebrospinal fluid flow. II. Physiology of respiration-related pulsations.
    Schroth G; Klose U
    Neuroradiology; 1992; 35(1):10-5. PubMed ID: 1289732
    [TBL] [Abstract][Full Text] [Related]  

  • 57. B-waves in cerebral and spinal cerebrospinal fluid pulsation measurement by magnetic resonance imaging.
    Friese S; Hamhaber U; Erb M; Klose U
    J Comput Assist Tomogr; 2004; 28(2):255-62. PubMed ID: 15091131
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Detection of a relation between respiration and CSF pulsation with an echoplanar technique.
    Klose U; Strik C; Kiefer C; Grodd W
    J Magn Reson Imaging; 2000 Apr; 11(4):438-44. PubMed ID: 10767073
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Evaluation of basilar artery and cerebrospinal fluid dynamics using phase-contrast MRI: Comparison between mannitol and isotonic saline solution.
    Hori A; Seo W; Miyoshi K; Makita K; Hanazono K; Nakade T
    Vet Radiol Ultrasound; 2020 Nov; 61(6):680-687. PubMed ID: 32713081
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Real-time quantification of in vivo cerebrospinal fluid velocity using the functional magnetic resonance imaging inflow effect.
    Diorio TC; Nair VV; Patel NM; Hedges LE; Rayz VL; Tong Y
    NMR Biomed; 2024 Jun; ():e5200. PubMed ID: 38881247
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.