These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

55 related articles for article (PubMed ID: 3651873)

  • 1. [Optimization of oxygen delivery administered with a T-shaped device].
    Bastien O; Guichard G; Neidecker J; Deplace C
    Cah Anesthesiol; 1987 Jul; 35(4):275-7. PubMed ID: 3651873
    [No Abstract]   [Full Text] [Related]  

  • 2. Performance of a MedArray silicone hollow fiber oxygenator.
    LaFayette NG; Schewe RE; Montoya JP; Cook KE
    ASAIO J; 2009; 55(4):382-7. PubMed ID: 19381081
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of an oxygen delivery device for weaning potentially infectious critically ill patients.
    So CY; Gomersall CD; Chui PT; Chan MT
    Anaesthesia; 2004 Jul; 59(7):710-4. PubMed ID: 15200546
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung.
    Hattler BG; Reeder GD; Sawzik PJ; Walters FR; Pham SM; Kormos RL; Keenan RJ; Griffith BP; Armitage JM; Hardesty RL
    J Heart Lung Transplant; 1994; 13(6):1003-8. PubMed ID: 7865505
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Membrane oxygenators of the blood].
    Krajewska B; Leszko M
    Polim Med; 1983; 13(3-4):93-116. PubMed ID: 6438615
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mathematical model for the calculation of oxygen concentrations in a closed circuit oxygen rebreathing apparatus.
    Neubauer B; Zander R; Tetzlaff K
    Aviat Space Environ Med; 1997 Aug; 68(8):722-5. PubMed ID: 9262815
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Oxygen-enhanced magnetic resonance imaging: influence of different gas delivery methods on the T1-changes of the lungs.
    Molinari F; Puderbach M; Eichinger M; Ley S; Fink C; Bonomo L; Kauczor HU; Bock M
    Invest Radiol; 2008 Jun; 43(6):427-32. PubMed ID: 18496048
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of the oxygenator: past, present, and future.
    Iwahashi H; Yuri K; Nosé Y
    J Artif Organs; 2004; 7(3):111-20. PubMed ID: 15558331
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficiency of oxygen administration: sequential gas delivery versus "flow into a cone" methods.
    Slessarev M; Somogyi R; Preiss D; Vesely A; Sasano H; Fisher JA
    Crit Care Med; 2006 Mar; 34(3):829-34. PubMed ID: 16505664
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of a vital capacity maneuver on pulmonary gas exchange after cardiopulmonary bypass.
    Murphy GS; Szokol JW; Curran RD; Votapka TV; Vender JS
    J Cardiothorac Vasc Anesth; 2001 Jun; 15(3):336-40. PubMed ID: 11426365
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A problem with a Sechrist air/oxygen blender device.
    Wajon P; Walsh R; Symons N
    Anaesth Intensive Care; 1995 Aug; 23(4):518-9. PubMed ID: 7485958
    [No Abstract]   [Full Text] [Related]  

  • 12. The intravascular oxygenator (IVOX): preliminary results of a new means of performing extrapulmonary gas exchange.
    Gentilello LM; Jurkovich GJ; Gubler KD; Anardi DM; Heiskell R
    J Trauma; 1993 Sep; 35(3):399-404. PubMed ID: 8371298
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures.
    Brown MK; Willms DC
    Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Heliox does not affect gas exchange during high-frequency oscillatory ventilation if tidal volume is held constant.
    Katz AL; Gentile MA; Craig DM; Quick G; Cheifetz IM
    Crit Care Med; 2003 Jul; 31(7):2006-9. PubMed ID: 12847396
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The history of extracorporeal oxygenators.
    Lim MW
    Anaesthesia; 2006 Oct; 61(10):984-95. PubMed ID: 16978315
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intravascular blood oxygenation using hollow fibers in a disk-shaped configuration: experimental evaluation of the relationship between porosity and performance.
    Cattaneo GF; Reul H; Schmitz-Rode T; Steinseifer U
    ASAIO J; 2006; 52(2):180-5. PubMed ID: 16557105
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intermittent oxygen delivery in an Ohmeda Unitrol anesthesia machine due to a faulty O-ring check valve assembly.
    Varga DA; Guttery JS; Grundy BL
    Anesth Analg; 1987 Nov; 66(11):1200-1. PubMed ID: 3662073
    [No Abstract]   [Full Text] [Related]  

  • 18. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies.
    Zierenberg JR; Fujioka H; Cook KE; Grotberg JB
    J Biomech Eng; 2008 Jun; 130(3):031019. PubMed ID: 18532868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of hemodynamics on the performances of intravascular gas exchangers.
    Mihaljevic T; von Segesser LK; Tönz M; Leskosek B; Turina MI
    Ann Thorac Surg; 1995 Dec; 60(6):1665-70. PubMed ID: 8787460
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Support when gas exchange fails--ECMO, ECCO2R and IVOX.
    Lanigan CJ; Withington PS
    Clin Intensive Care; 1991; 2(4):210-6. PubMed ID: 10148882
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.