1. [Optimization of oxygen delivery administered with a T-shaped device]. Bastien O; Guichard G; Neidecker J; Deplace C Cah Anesthesiol; 1987 Jul; 35(4):275-7. PubMed ID: 3651873 [No Abstract] [Full Text] [Related]
2. Performance of a MedArray silicone hollow fiber oxygenator. LaFayette NG; Schewe RE; Montoya JP; Cook KE ASAIO J; 2009; 55(4):382-7. PubMed ID: 19381081 [TBL] [Abstract][Full Text] [Related]
3. Performance of an oxygen delivery device for weaning potentially infectious critically ill patients. So CY; Gomersall CD; Chui PT; Chan MT Anaesthesia; 2004 Jul; 59(7):710-4. PubMed ID: 15200546 [TBL] [Abstract][Full Text] [Related]
4. Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung. Hattler BG; Reeder GD; Sawzik PJ; Walters FR; Pham SM; Kormos RL; Keenan RJ; Griffith BP; Armitage JM; Hardesty RL J Heart Lung Transplant; 1994; 13(6):1003-8. PubMed ID: 7865505 [TBL] [Abstract][Full Text] [Related]
5. [Membrane oxygenators of the blood]. Krajewska B; Leszko M Polim Med; 1983; 13(3-4):93-116. PubMed ID: 6438615 [TBL] [Abstract][Full Text] [Related]
6. Mathematical model for the calculation of oxygen concentrations in a closed circuit oxygen rebreathing apparatus. Neubauer B; Zander R; Tetzlaff K Aviat Space Environ Med; 1997 Aug; 68(8):722-5. PubMed ID: 9262815 [TBL] [Abstract][Full Text] [Related]
7. Oxygen-enhanced magnetic resonance imaging: influence of different gas delivery methods on the T1-changes of the lungs. Molinari F; Puderbach M; Eichinger M; Ley S; Fink C; Bonomo L; Kauczor HU; Bock M Invest Radiol; 2008 Jun; 43(6):427-32. PubMed ID: 18496048 [TBL] [Abstract][Full Text] [Related]
8. Development of the oxygenator: past, present, and future. Iwahashi H; Yuri K; Nosé Y J Artif Organs; 2004; 7(3):111-20. PubMed ID: 15558331 [TBL] [Abstract][Full Text] [Related]
9. Efficiency of oxygen administration: sequential gas delivery versus "flow into a cone" methods. Slessarev M; Somogyi R; Preiss D; Vesely A; Sasano H; Fisher JA Crit Care Med; 2006 Mar; 34(3):829-34. PubMed ID: 16505664 [TBL] [Abstract][Full Text] [Related]
10. Influence of a vital capacity maneuver on pulmonary gas exchange after cardiopulmonary bypass. Murphy GS; Szokol JW; Curran RD; Votapka TV; Vender JS J Cardiothorac Vasc Anesth; 2001 Jun; 15(3):336-40. PubMed ID: 11426365 [TBL] [Abstract][Full Text] [Related]
11. A problem with a Sechrist air/oxygen blender device. Wajon P; Walsh R; Symons N Anaesth Intensive Care; 1995 Aug; 23(4):518-9. PubMed ID: 7485958 [No Abstract] [Full Text] [Related]
12. The intravascular oxygenator (IVOX): preliminary results of a new means of performing extrapulmonary gas exchange. Gentilello LM; Jurkovich GJ; Gubler KD; Anardi DM; Heiskell R J Trauma; 1993 Sep; 35(3):399-404. PubMed ID: 8371298 [TBL] [Abstract][Full Text] [Related]
13. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures. Brown MK; Willms DC Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245 [TBL] [Abstract][Full Text] [Related]
14. Heliox does not affect gas exchange during high-frequency oscillatory ventilation if tidal volume is held constant. Katz AL; Gentile MA; Craig DM; Quick G; Cheifetz IM Crit Care Med; 2003 Jul; 31(7):2006-9. PubMed ID: 12847396 [TBL] [Abstract][Full Text] [Related]
15. The history of extracorporeal oxygenators. Lim MW Anaesthesia; 2006 Oct; 61(10):984-95. PubMed ID: 16978315 [TBL] [Abstract][Full Text] [Related]
16. Intravascular blood oxygenation using hollow fibers in a disk-shaped configuration: experimental evaluation of the relationship between porosity and performance. Cattaneo GF; Reul H; Schmitz-Rode T; Steinseifer U ASAIO J; 2006; 52(2):180-5. PubMed ID: 16557105 [TBL] [Abstract][Full Text] [Related]
17. Intermittent oxygen delivery in an Ohmeda Unitrol anesthesia machine due to a faulty O-ring check valve assembly. Varga DA; Guttery JS; Grundy BL Anesth Analg; 1987 Nov; 66(11):1200-1. PubMed ID: 3662073 [No Abstract] [Full Text] [Related]
18. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies. Zierenberg JR; Fujioka H; Cook KE; Grotberg JB J Biomech Eng; 2008 Jun; 130(3):031019. PubMed ID: 18532868 [TBL] [Abstract][Full Text] [Related]
19. Influence of hemodynamics on the performances of intravascular gas exchangers. Mihaljevic T; von Segesser LK; Tönz M; Leskosek B; Turina MI Ann Thorac Surg; 1995 Dec; 60(6):1665-70. PubMed ID: 8787460 [TBL] [Abstract][Full Text] [Related]
20. Support when gas exchange fails--ECMO, ECCO2R and IVOX. Lanigan CJ; Withington PS Clin Intensive Care; 1991; 2(4):210-6. PubMed ID: 10148882 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]