These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 36527191)

  • 1. Revisiting exit block after entrance block: Investigation of ablation index-guided pulmonary vein isolation.
    Nakashima T; Nagase M; Shibahara T; Ono D; Yamada T; Tanabe G; Suzuki K; Yamaura M; Ido T; Takahashi S; Okura H; Aoyama T
    Pacing Clin Electrophysiol; 2023 Feb; 46(2):144-151. PubMed ID: 36527191
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of exit block following pulmonary vein isolation: far-field capture masquerading as entrance without exit block.
    Vijayaraman P; Dandamudi G; Naperkowski A; Oren J; Storm R; Ellenbogen KA
    Heart Rhythm; 2012 Oct; 9(10):1653-9. PubMed ID: 22683746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blocking the pulmonary vein to left atrium conduction in addition to the entrance block enhances clinical efficacy in atrial fibrillation ablation.
    Chen S; Meng W; Sheng He D; Chen G; Zhang F; Yan Y; Zhu-Ge Y; Liu S
    Pacing Clin Electrophysiol; 2012 May; 35(5):524-31. PubMed ID: 22385041
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The time course of exit and entrance block during cryoballoon pulmonary vein isolation.
    Andrade J; Khairy P; Dubuc M; Deyell MW; Roy D; Talajic M; Thibault B; Guerra PG; Rivard L; Macle L
    Europace; 2014 Apr; 16(4):500-4. PubMed ID: 23918789
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intermediate term outcome after electrogram guided segmental ostial pulmonary vein isolation using an 8 mm tip catheter for paroxysmal atrial fibrillation.
    Pawar P; Vadivelu R; Bachani N; Jeyashree K; Sharma R; Rathi C; Jadwani J; Bera D; Lokhandwala Y
    Indian Heart J; 2019; 71(5):381-386. PubMed ID: 32035520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New approach to pulmonary vein isolation for atrial fibrillation using a multielectrode basket catheter.
    Kumagai K; Noguchi H; Ogawa M; Nakashima H; Zhang B; Miura S; Saku K
    Circ J; 2006 Jan; 70(1):88-93. PubMed ID: 16377930
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lessons from dissociated pulmonary vein potentials: entry block implies exit block.
    Duytschaever M; De Meyer G; Acena M; El-Haddad M; De Greef Y; Van Heuverswyn F; Vandekerckhove Y; Tavernier R; Lee G; Kistler P
    Europace; 2013 Jun; 15(6):805-12. PubMed ID: 23275474
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical predictors and outcomes associated with acute return of pulmonary vein conduction during pulmonary vein isolation for treatment of atrial fibrillation.
    Sauer WH; McKernan ML; Lin D; Gerstenfeld EP; Callans DJ; Marchlinski FE
    Heart Rhythm; 2006 Sep; 3(9):1024-8. PubMed ID: 16945795
    [TBL] [Abstract][Full Text] [Related]  

  • 9. No association between dormant conduction sites and pulmonary vein reconnection sites in late atrial fibrillation recurrence after catheter ablation.
    Iso K; Watanabe I; Okumura Y; Nagashima K; Takahashi K; Kurokawa S; Arai M; Watanabe R; Wakamatsu Y; Ohkubo K; Nakai T; Hirayama A; Sonoda K; Tosaka T
    J Cardiol; 2018 Dec; 72(6):488-493. PubMed ID: 30318077
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.
    Steven D; Reddy VY; Inada K; Roberts-Thomson KC; Seiler J; Stevenson WG; Michaud GF
    Heart Rhythm; 2010 Mar; 7(3):323-30. PubMed ID: 20185104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence of pulmonary vein conduction recovery in patients without clinical recurrence after ablation of paroxysmal atrial fibrillation: mechanistic implications.
    Jiang RH; Po SS; Tung R; Liu Q; Sheng X; Zhang ZW; Sun YX; Yu L; Zhang P; Fu GS; Jiang CY
    Heart Rhythm; 2014 Jun; 11(6):969-76. PubMed ID: 24632180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Utility of exit block for identifying electrical isolation of the pulmonary veins.
    Gerstenfeld EP; Dixit S; Callans D; Rho R; Rajawat Y; Zado E; Marchlinski FE
    J Cardiovasc Electrophysiol; 2002 Oct; 13(10):971-9. PubMed ID: 12435181
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reconnection Sites in Redo Ablation after Cryoballoon Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation.
    Nolasco RR; Leon-Larios G; Bazzini-Carranza DE; Zavaleta E; Calixto-Vargas O
    Arq Bras Cardiol; 2021 Jul; 117(1):100-105. PubMed ID: 34320077
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Loss of local capture of the pulmonary vein myocardium after antral isolation: prevalence and clinical significance.
    Squara F; Liuba I; Chik W; Santangeli P; Zado ES; Callans DJ; Marchlinski FE
    J Cardiovasc Electrophysiol; 2015 Mar; 26(3):242-50. PubMed ID: 25404507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution mapping as an alternative for exit block testing in the presence of entrance block after high-power short-duration pulmonary vein isolation.
    Weyand S; Beuter M; Heinzmann D; Seizer P
    Herzschrittmacherther Elektrophysiol; 2022 Dec; 33(4):440-445. PubMed ID: 36083317
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients: The PRAISE Study Results.
    Hussein A; Das M; Riva S; Morgan M; Ronayne C; Sahni A; Shaw M; Todd D; Hall M; Modi S; Natale A; Dello Russo A; Snowdon R; Gupta D
    Circ Arrhythm Electrophysiol; 2018 Sep; 11(9):e006576. PubMed ID: 30354288
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultra-high-density mapping of conduction gaps and atrial tachycardias: Distinctive patterns following pulmonary vein isolation with cryoballoon or contact-force-guided radiofrequency current.
    Gunawardene MA; Eickholt C; Akbulak RÖ; Jularic M; Klatt N; Hartmann J; Schlüter M; Meyer C; Willems S; Schaeffer B
    J Cardiovasc Electrophysiol; 2020 May; 31(5):1051-1061. PubMed ID: 32107811
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.
    Anter E; Tschabrunn CM; Contreras-Valdes FM; Li J; Josephson ME
    Heart Rhythm; 2015 Sep; 12(9):1927-34. PubMed ID: 26001505
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous isolation of superior and inferior pulmonary veins on both the left and right sides could yield better outcomes in patients with paroxysmal atrial fibrillation.
    Takigawa M; Kuwahara T; Takahashi A; Okubo K; Takahashi Y; Nakashima E; Yamao K; Watari Y; Nakajima J; Takagi K; Fujino T; Kimura S; Hikita H; Hirao K; Isobe M
    Europace; 2015 May; 17(5):732-40. PubMed ID: 25618743
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of pulmonary vein reconnection patterns after multielectrode phased radiofrequency- and cryoballoon ablation of atrial fibrillation.
    Wieczorek M; Sassani K; Hoeltgen R
    BMC Cardiovasc Disord; 2020 Apr; 20(1):197. PubMed ID: 32326885
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.