BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 36544053)

  • 1. High-resolution 3D T2-weighted SPACE sequence with compressed sensing for the prostate gland: diagnostic performance in comparison with conventional T2-weighted images.
    Choi MH; Lee YJ; Jung SE; Han D
    Abdom Radiol (NY); 2023 Mar; 48(3):1090-1099. PubMed ID: 36544053
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging.
    Tanaka U; Ueno Y; Morinaga Y; Miyake H; Kyotani K; Ueda Y; Kitajima K; Sofue K; Suenaga Y; Sugimura K; Takahashi S
    Jpn J Radiol; 2017 Dec; 35(12):707-717. PubMed ID: 28983811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy.
    Bathala TK; Venkatesan AM; Ma J; Bhosale P; Wei W; Kudchadker RJ; Wang J; Anscher MS; Tang C; Bruno TL; Frank SJ; Szklaruk J
    Brachytherapy; 2020; 19(4):484-490. PubMed ID: 32402544
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prostate cancer: Comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection.
    Rosenkrantz AB; Neil J; Kong X; Melamed J; Babb JS; Taneja SS; Taouli B
    AJR Am J Roentgenol; 2010 Feb; 194(2):446-52. PubMed ID: 20093608
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accelerated Three-dimensional T2-Weighted Turbo-Spin-Echo Sequences with Inner-Volume Excitation and Iterative Denoising in the Setting of Pelvis MRI at 1.5T: Impact on Image Quality and Lesion Detection.
    Almansour H; Weiland E; Kuehn B; Kannengiesser S; Gassenmaier S; Herrmann J; Hoffmann R; Othman AE; Afat S
    Acad Radiol; 2022 Nov; 29(11):e248-e259. PubMed ID: 35144868
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the most optimal multiparametric magnetic resonance imaging sequence for determining pathological length of capsular contact.
    Onay A; Vural M; Armutlu A; Ozel Yıldız S; Kiremit MC; Esen T; Bakır B
    Eur J Radiol; 2019 Mar; 112():192-199. PubMed ID: 30777210
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging.
    Hossein J; Fariborz F; Mehrnaz R; Babak R
    Eur J Radiol Open; 2019; 6():36-41. PubMed ID: 30619918
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction-First Experience.
    Fritz J; Raithel E; Thawait GK; Gilson W; Papp DF
    Invest Radiol; 2016 Jun; 51(6):400-9. PubMed ID: 26685106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. T2 Turbo Spin Echo With Compressed Sensing and Propeller Acquisition (Sampling k-Space by Utilizing Rotating Blades) for Fast and Motion Robust Prostate MRI: Comparison With Conventional Acquisition.
    Bischoff LM; Katemann C; Isaak A; Mesropyan N; Wichtmann B; Kravchenko D; Endler C; Kuetting D; Pieper CC; Ellinger J; Weber O; Attenberger U; Luetkens JA
    Invest Radiol; 2023 Mar; 58(3):209-215. PubMed ID: 36070533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T.
    Sung J; Jee WH; Jung JY; Jang J; Kim JS; Kim YH; Ha KY
    Korean J Radiol; 2017; 18(1):249-259. PubMed ID: 28096733
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequence.
    Fütterer JJ; Yakar D; Strijk SP; Barentsz JO
    Eur J Radiol; 2008 Jan; 65(1):66-71. PubMed ID: 18164156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.
    Lee S; Jee WH; Jung JY; Lee SY; Ryu KS; Ha KY
    Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Compressed sensing 3D T2WI radiomics model: improving diagnostic performance in muscle invasion of bladder cancer.
    Li S; Fan Z; Guo J; Li D; Chen Z; Zhang X; Wang Y; Li Y; Yang G; Wang X
    BMC Med Imaging; 2024 Jun; 24(1):148. PubMed ID: 38886638
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fast T2-Weighted Imaging With Deep Learning-Based Reconstruction: Evaluation of Image Quality and Diagnostic Performance in Patients Undergoing Radical Prostatectomy.
    Park JC; Park KJ; Park MY; Kim MH; Kim JK
    J Magn Reson Imaging; 2022 Jun; 55(6):1735-1744. PubMed ID: 34773449
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.
    Polanec SH; Lazar M; Wengert GJ; Bickel H; Spick C; Susani M; Shariat S; Clauser P; Baltzer PAT
    Eur Radiol; 2018 Apr; 28(4):1634-1641. PubMed ID: 29134351
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T.
    Yang F; Pan X; Zhu K; Xiao Y; Yue X; Peng P; Zhang X; Huang J; Chen J; Yuan Y; Sun J
    Eur J Radiol; 2022 Nov; 156():110562. PubMed ID: 36270194
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Super-Resolution Magnetic Resonance Imaging of the Knee Using 2-Dimensional Turbo Spin Echo Imaging.
    Van Dyck P; Smekens C; Vanhevel F; De Smet E; Roelant E; Sijbers J; Jeurissen B
    Invest Radiol; 2020 Aug; 55(8):481-493. PubMed ID: 32404629
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of vertebral metastases: a comparison between the modified Dixon turbo spin echo T
    Hahn S; Lee YH; Suh JS
    Br J Radiol; 2018 May; 91(1085):20170782. PubMed ID: 29393668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification.
    Meier-Schroers M; Marx C; Schmeel FC; Wolter K; Gieseke J; Block W; Sprinkart AM; Traeber F; Willinek W; Schild HH; Kukuk GM
    Eur Radiol; 2018 Jan; 28(1):24-30. PubMed ID: 28687915
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accelerated Internal Auditory Canal Screening Magnetic Resonance Imaging Protocol With Compressed Sensing 3-Dimensional T2-Weighted Sequence.
    Yuhasz M; Hoch MJ; Hagiwara M; Bruno MT; Babb JS; Raithel E; Forman C; Anwar A; Thomas Roland J; Shepherd TM
    Invest Radiol; 2018 Dec; 53(12):742-747. PubMed ID: 30020139
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.