These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 3654733)

  • 21. In vivo comparison of replamineform, Silastic, and bioelectric polyurethane arterial grafts.
    Hiratzka LF; Goeken JA; White RA; Wright CB
    Arch Surg; 1979 Jun; 114(6):698-702. PubMed ID: 454153
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Increased compliance near vascular anastomoses.
    Hasson JE; Megerman J; Abbott WM
    J Vasc Surg; 1985 May; 2(3):419-23. PubMed ID: 3999232
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A meta-analysis to compare Dacron versus polytetrafluroethylene grafts for above-knee femoropopliteal artery bypass.
    Rychlik IJ; Davey P; Murphy J; O'Donnell ME
    J Vasc Surg; 2014 Aug; 60(2):506-15. PubMed ID: 24973288
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Experimental evaluation of the dialdehyde starch preserved bovine internal mammary artery as a small diameter arterial substitute.
    Welz A; Triefenbach R; Murrmann G; Grenzner S; Hammer C
    J Card Surg; 1992 Jun; 7(2):163-9. PubMed ID: 1606368
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Very small-diameter polyurethane vascular prostheses with rapid endothelialization for coronary artery bypass grafting.
    Okoshi T; Soldani G; Goddard M; Galletti PM
    J Thorac Cardiovasc Surg; 1993 May; 105(5):791-5. PubMed ID: 8487558
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.
    Sonoda H; Takamizawa K; Nakayama Y; Yasui H; Matsuda T
    J Biomed Mater Res A; 2003 May; 65(2):170-81. PubMed ID: 12734809
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A novel bioengineered small-caliber vascular graft incorporating heparin and sirolimus: excellent 6-month patency.
    Ishii Y; Sakamoto S; Kronengold RT; Virmani R; Rivera EA; Goldman SM; Prechtel EJ; Hill JG; Damiano RJ
    J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1237-45; discussion 1245-6. PubMed ID: 18544361
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Healing characteristics of small-calibre vascular prostheses coated with plasmin-treated fibrin--an experimental study.
    Pfeiffer T; Kever M; Grabitz K; Reiher L; Müller KM; Hildebrand A; Sandmann W
    Vasa; 2000 May; 29(2):117-24. PubMed ID: 10901089
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The effect of wall mechanical properties on patency of arterial grafts.
    Kidson IG
    Ann R Coll Surg Engl; 1983 Jan; 65(1):24-9. PubMed ID: 6218775
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparative in vitro evaluations of vascular graft compliance during dynamic loading.
    Igo SR; Meador JW; Frazier OH
    ASAIO Trans; 1988; 34(3):785-8. PubMed ID: 3196599
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Short-term in vivo stability of endothelial-lined polyester elastomer and polytetrafluoroethylene grafts.
    Kesler KA; Herring MB; Arnold MP; Park HM; Baughman S; Glover JL
    Ann Vasc Surg; 1986 May; 1(1):60-5. PubMed ID: 3504691
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of compliance mismatch on vascular graft patency.
    Abbott WM; Megerman J; Hasson JE; L'Italien G; Warnock DF
    J Vasc Surg; 1987 Feb; 5(2):376-82. PubMed ID: 3102762
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Acceleration of neointima formation in vascular prostheses by transplantation of autologous venous tissue fragments. Application to small-diameter grafts.
    Noishiki Y; Tomizawa Y; Yamane Y; Okoshi T; Satoh S; Matsumoto A
    J Thorac Cardiovasc Surg; 1993 May; 105(5):796-804. PubMed ID: 8487559
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental use of prosthetic grafts in microvascular surgery.
    Demiri EC; Iordanidis SL; Mantinaos CF
    Handchir Mikrochir Plast Chir; 1999 Mar; 31(2):102-6. PubMed ID: 10337554
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Thrombogenicity and the interaction of proteins, platelets and white cells.
    Long J; DeSantis S; Shors E; Uszler M; Wuest C; Klein S; White R
    Biomater Med Devices Artif Organs; 1983; 11(1):63-72. PubMed ID: 6615998
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Graft compliance and anastomotic flow patterns.
    Wang LC; Guo GX; Tu R; Hwang NH
    ASAIO Trans; 1990; 36(2):90-4. PubMed ID: 2340213
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Development of artificial blood vessel suitable for cerebrovascular surgery: improvement in the mechanical properties].
    Miyamoto S
    Nihon Geka Hokan; 1991 Jan; 60(1):25-37. PubMed ID: 1819236
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Incidentally detected stenoses proximal to grafts originating below the common femoral artery: do they affect graft patency or warrant repair in asymptomatic patients?
    Treiman GS; Ashrafi A; Lawrence PF
    J Vasc Surg; 2000 Dec; 32(6):1180-9. PubMed ID: 11107091
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An in vitro endothelialized compliant vascular graft minimizes anastomotic hyperplasia.
    Miwa H; Matsuda T; Tani N; Kondo K; Iida F
    ASAIO J; 1993; 39(3):M501-5. PubMed ID: 8268587
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Factors affecting the patency of small-caliber prostheses: Observations in a suitable canine model.
    Jones DN; Rutherford RB; Ikezawa T; Nishikimi N; Ishibashi H; Whitehill TA
    J Vasc Surg; 1991 Oct; 14(4):441-8; discussion 448-51. PubMed ID: 1920641
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.