These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 36549174)

  • 21. Impedance scaling for gold and platinum microelectrodes.
    Fan B; Wolfrum B; Robinson JT
    J Neural Eng; 2021 Sep; 18(5):. PubMed ID: 34433150
    [No Abstract]   [Full Text] [Related]  

  • 22. Effect of electrode material on the sensitivity of interdigitated electrodes used for Electrical Cell-Substrate Impedance Sensing technology.
    Martinez J; Montalibet A; McAdams E; Faivre M; Ferrigno R
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():813-816. PubMed ID: 29059996
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Graphene Microelectrodes for Real-Time Impedance Spectroscopy of Neural Cells.
    Niaraki A; McNamara MC; Montazami R; Hashemi NN
    ACS Appl Bio Mater; 2022 Jan; 5(1):113-122. PubMed ID: 35014836
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Au-PEDOT/rGO nanocomposites functionalized graphene electrochemical transistor for ultra-sensitive detection of acetaminophen in human urine.
    Tao T; Gao N; He H; Zhou R; Tu B; Cai Z; Chang G; He Y; Ji X
    Anal Chim Acta; 2022 Jan; 1191():339306. PubMed ID: 35033240
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Individually addressable microelectrode arrays fabricated with gold-coated pencil graphite particles for multiplexed and high sensitive impedance immunoassays.
    Zhang Y; Wang H; Nie J; Zhang Y; Shen G; Yu R
    Biosens Bioelectron; 2009 Sep; 25(1):34-40. PubMed ID: 19559589
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The Influence of Electrode Design on Detecting the Effects of Ferric Ammonium Citrate (FAC) on Pre-Osteoblast through Electrical Cell-Substrate Impedance Sensing (ECIS).
    Zhang Z; Yuan X; Guo H; Shang P
    Biosensors (Basel); 2023 Feb; 13(3):. PubMed ID: 36979534
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparative study on the viscoelasticity and morphology of polyaniline films galvanostatically grown on bare and 4-aminothiophenol-modified gold electrodes using an electrochemical quartz crystal impedance system and SEM.
    Xie Q; Zhang Y; Xiang C; Tang J; Li Y; Zhao Q; Yao S
    Anal Sci; 2001 May; 17(5):613-20. PubMed ID: 11708142
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays.
    Gunalan K; Warren DJ; Perry JD; Normann RA; Clark GA
    J Neurosci Methods; 2009 Apr; 178(2):263-9. PubMed ID: 19150630
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Label-free E-DNA biosensor based on PANi-RGO-G*NPs for detection of cell-free fetal DNA in maternal blood and fetal gender determination in early pregnancy.
    Malmir M; Arjomandi J; Khosroshahi AG; Moradi M; Shi H
    Biosens Bioelectron; 2021 Oct; 189():113356. PubMed ID: 34077863
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electrical cell-substrate impedance sensing with field-effect transistors is able to unravel cellular adhesion and detachment processes on a single cell level.
    Susloparova A; Koppenhöfer D; Law JK; Vu XT; Ingebrandt S
    Lab Chip; 2015 Feb; 15(3):668-79. PubMed ID: 25412224
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Parylene-C-Coated indium tin oxide electrodes for the optical- and electrical-impedance characterization of cells.
    Kim S; Cho S
    J Nanosci Nanotechnol; 2012 Jul; 12(7):5830-4. PubMed ID: 22966664
    [TBL] [Abstract][Full Text] [Related]  

  • 32. N-Doped Reduced Graphene Oxide/Gold Nanoparticles Composite as an Improved Sensing Platform for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid.
    Minta D; González Z; Wiench P; Gryglewicz S; Gryglewicz G
    Sensors (Basel); 2020 Aug; 20(16):. PubMed ID: 32784787
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dielectric spectroscopy as a viable biosensing tool for cell and tissue characterization and analysis.
    Heileman K; Daoud J; Tabrizian M
    Biosens Bioelectron; 2013 Nov; 49():348-59. PubMed ID: 23796534
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Microstructural and electrochemical impedance characterization of bio-functionalized ultrafine ZnS nanocrystals-reduced graphene oxide hybrid for immunosensor applications.
    Mishra SK; Srivastava AK; Kumar D; Biradar AM; Rajesh
    Nanoscale; 2013 Nov; 5(21):10494-503. PubMed ID: 24056976
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Glucose oxidase immobilized amine terminated multiwall carbon nanotubes/reduced graphene oxide/polyaniline/gold nanoparticles modified screen-printed carbon electrode for highly sensitive amperometric glucose detection.
    Maity D; C R M; R T RK
    Mater Sci Eng C Mater Biol Appl; 2019 Dec; 105():110075. PubMed ID: 31546385
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis, based on signal amplification of graphene and a gold nanoparticle-polyaniline nanocomposite.
    Liu C; Jiang D; Xiang G; Liu L; Liu F; Pu X
    Analyst; 2014 Nov; 139(21):5460-5. PubMed ID: 25171135
    [TBL] [Abstract][Full Text] [Related]  

  • 37. How to Choose a Proper Theoretical Analysis Model Based on Cell Adhesion and Nonadhesion Impedance Measurement.
    Wei M; Zhang R; Zhang F; Yang N; Zhang Y; Li G
    ACS Sens; 2021 Mar; 6(3):673-687. PubMed ID: 33724797
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Development of an Efficient Voltammetric Sensor for the Monitoring of 4-Aminophenol Based on Flexible Laser Induced Graphene Electrodes Modified with MWCNT-PANI.
    Nasraoui S; Ameur S; Al-Hamry A; Ben Ali M; Kanoun O
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161578
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Concept for E.coli detection using interdigitated microelectrode impedance sensor.
    Settu K; Liu JT; Chen CJ; Tsai JZ; Chang SJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1712-5. PubMed ID: 24110036
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hydrogel-based diffusion chip with Electric Cell-substrate Impedance Sensing (ECIS) integration for cell viability assay and drug toxicity screening.
    Tran TB; Cho S; Min J
    Biosens Bioelectron; 2013 Dec; 50():453-9. PubMed ID: 23911660
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.