These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 3655665)

  • 1. Ethylene glycol-stabilized haemolysates for glycated haemoglobin assay. Further analytical investigations and applications to quality control programmes.
    Mosca A; Carpinelli A; Bonini PA
    J Clin Chem Clin Biochem; 1987 Jul; 25(7):447-50. PubMed ID: 3655665
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preparation and control of ethylene glycol-stabilized haemolysates for glycated haemoglobin assay.
    Mosca A; Carpinelli A; Paleari R; Carenini A; Bonini P; Franzini C
    J Clin Chem Clin Biochem; 1985 Jun; 23(6):361-4. PubMed ID: 4020331
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ethylene glycol-stabilized haemolysates as control material in haemoglobinometry.
    Franzini C
    Clin Chim Acta; 1983 Dec; 135(2):175-9. PubMed ID: 6652926
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An inexpensive, rapid and precise affinity chromatography method for the measurement of glycosylated haemoglobins.
    Hall PM; Cook JG; Gould BJ
    Ann Clin Biochem; 1983 May; 20(Pt 3):129-35. PubMed ID: 6881895
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A re-evaluation of glycohaemoglobin standardisation: the Italian experience with 119 laboratories and 12 methods.
    Mosca A; Paleari R; Trapolino A; Capani F; Pagano G; Plebani M
    Eur J Clin Chem Clin Biochem; 1997 Mar; 35(3):243-8. PubMed ID: 9127749
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-performance liquid chromatographic separation of human haemoglobins. Simultaneous quantitation of foetal and glycated haemoglobins.
    Bisse E; Wieland H
    J Chromatogr; 1988 Dec; 434(1):95-110. PubMed ID: 2468680
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interlaboratory standardization of glycated hemoglobin determinations.
    Little RR; England JD; Wiedmeyer HM; McKenzie EM; Mitra R; Erhart PM; Durham JB; Goldstein DE
    Clin Chem; 1986 Feb; 32(2):358-60. PubMed ID: 3943200
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a reference material for glycated haemoglobin.
    Weykamp CW; Penders TJ; Muskiet FA; van der Slik W
    Eur J Clin Chem Clin Biochem; 1996 Jan; 34(1):67-72. PubMed ID: 8704040
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Separation of glycosylated haemoglobins using immobilized phenylboronic acid. Effect of ligand concentration, column operating conditions, and comparison with ion-exchange and isoelectric-focusing.
    Middle FA; Bannister A; Bellingham AJ; Dean PD
    Biochem J; 1983 Mar; 209(3):771-9. PubMed ID: 6870791
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Glycohaemoglobin: comparison of 12 analytical methods, applied to lyophilized haemolysates by 101 laboratories in an external quality assurance programme.
    Weykamp CW; Penders TJ; Muskiet FA; van der Slik W
    Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():169-74. PubMed ID: 8466148
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Standardization of glycated haemoglobin assays throughout the Northern region of England: a pilot study.
    Gibb I; Parnham AJ; Lord C; Steffes MW; Bucksa J; Marshall S
    Diabet Med; 1997 Jul; 14(7):584-8. PubMed ID: 9223397
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of the determination of glucosylated haemoglobin by isoelectric focusing and cation-exchange chromatography on minicolumns.
    Hjelm Poulsen J; Jespersen J
    Scand J Clin Lab Invest; 1986 May; 46(3):259-63. PubMed ID: 2424077
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Glycated haemoglobin analyses--assessment of within- and between-laboratory performance in a large UK region.
    John WG
    Ann Clin Biochem; 1987 Sep; 24 ( Pt 5)():453-60. PubMed ID: 3662395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Standardization of glycohemoglobin determinations in the clinical laboratory: three years of experience.
    Bodor GS; Little RR; Garrett N; Brown W; Goldstein DE; Nahm MH
    Clin Chem; 1992 Dec; 38(12):2414-8. PubMed ID: 1458576
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of temperature on quantifying glycated (glycosylated) hemoglobin by cation-exchange chromatography.
    Flückiger R; Woodtli T
    Clin Chem; 1985 Jan; 31(1):114-7. PubMed ID: 3965186
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of whole blood storage on results for glycosylated hemoglobin as measured by ion-exchange chromatography, affinity chromatography, and colorimetry.
    Little RR; England JD; Wiedmeyer HM; Goldstein DE
    Clin Chem; 1983 Jun; 29(6):1113-5. PubMed ID: 6851106
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Purified haemoglobin preparations in the evaluation of HbA1c determination by ion exchange chromatography.
    Cohen MP; Witt J; Wu VY
    Ann Clin Biochem; 1993 May; 30 ( Pt 3)():265-71. PubMed ID: 8517609
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of glycosylated adult and foetal haemoglobins by affinity chromatography.
    Talwar D; Barr BB; Kesson CM; Robb DA
    Clin Chim Acta; 1983 Feb; 128(1):61-7. PubMed ID: 6188558
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparison of analytical methods for the estimation of glycosylated haemoglobins (author's transl)].
    Niederau CM; Reinauer H
    J Clin Chem Clin Biochem; 1981 Nov; 19(11):1097-101. PubMed ID: 7310330
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of three different assay procedures for the determination of HbA1 with special attention to the influence of pre-HbA1c, temperature and haemoglobin concentration.
    Kortlandt W; van Rijn HJ; Hoeke JO; Thijssen JH
    Ann Clin Biochem; 1985 May; 22 ( Pt 3)():261-8. PubMed ID: 4026185
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.