169 related articles for article (PubMed ID: 36556709)
1. Biomechanical Behavior of Narrow Dental Implants Made with Aluminum- and Vanadium-Free Alloys: A Finite Element Analysis.
Zapata JM; Leal E; Hunter R; de Souza RF; Borie E
Materials (Basel); 2022 Dec; 15(24):. PubMed ID: 36556709
[TBL] [Abstract][Full Text] [Related]
2. Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region.
Borie E; Orsi IA; Noritomi PY; Kemmoku DT
Int J Oral Maxillofac Implants; 2016; 31(1):101-10. PubMed ID: 26478969
[TBL] [Abstract][Full Text] [Related]
3. Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants.
Brizuela-Velasco A; Pérez-Pevida E; Jiménez-Garrudo A; Gil-Mur FJ; Manero JM; Punset-Fuste M; Chávarri-Prado D; Diéguez-Pereira M; Monticelli F
Biomed Res Int; 2017; 2017():2785863. PubMed ID: 29318142
[TBL] [Abstract][Full Text] [Related]
4. Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment.
Jażdżewska M; Kwidzińska DB; Seyda W; Fydrych D; Zieliński A
Materials (Basel); 2021 Oct; 14(21):. PubMed ID: 34771847
[TBL] [Abstract][Full Text] [Related]
5. Experimental evaluation of stress distribution with narrow diameter implants: A finite element analysis.
Cinel S; Celik E; Sagirkaya E; Sahin O
J Prosthet Dent; 2018 Mar; 119(3):417-425. PubMed ID: 28645665
[TBL] [Abstract][Full Text] [Related]
6. Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.
Kan B; Coskunses FM; Mutlu I; Ugur L; Meral DG
Int J Oral Maxillofac Surg; 2015 Jul; 44(7):908-13. PubMed ID: 25818310
[TBL] [Abstract][Full Text] [Related]
7. Improved pre-osteoblast response and mechanical compatibility of ultrafine-grained Ti-13Nb-13Zr alloy.
Park CH; Lee CS; Kim YJ; Jang JH; Suh JY; Park JW
Clin Oral Implants Res; 2011 Jul; 22(7):735-742. PubMed ID: 21121961
[TBL] [Abstract][Full Text] [Related]
8. Finite element stress analysis of Ti-6Al-4V and partially stabilized zirconia dental implant during clenching.
Choi AH; Matinlinna JP; Ben-Nissan B
Acta Odontol Scand; 2012 Sep; 70(5):353-61. PubMed ID: 21815837
[TBL] [Abstract][Full Text] [Related]
9. Correlation between abutment angulation and off-axial stresses on biomechanical behavior of titanium and zirconium implants in the anterior maxilla: A three-dimensional finite element analysis study.
Guguloth H; Duggineni CR; Chitturi RK; Sujesh M; Ravvali T; Amiti RR
J Indian Prosthodont Soc; 2019; 19(4):353-361. PubMed ID: 31649445
[TBL] [Abstract][Full Text] [Related]
10. Study on Osseointegration Capability of β-Type Ti-Nb-Zr-Ta-Si Alloy for Orthopedic Implants.
Sun Y; Liu Q; Yu Z; Ren L; Zhao X; Wang J
Materials (Basel); 2024 Jan; 17(2):. PubMed ID: 38276411
[TBL] [Abstract][Full Text] [Related]
11. Nanostructured Ti-13Nb-13Zr alloy for implant application-material scientific, technological, and biological aspects.
Klinge L; Kluy L; Spiegel C; Siemers C; Groche P; Coraça-Huber D
Front Bioeng Biotechnol; 2023; 11():1255947. PubMed ID: 37691899
[TBL] [Abstract][Full Text] [Related]
12. Mechanobiologically optimized Ti-35Nb-2Ta-3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy.
Mao C; Yu W; Jin M; Wang Y; Shang X; Lin L; Zeng X; Wang L; Lu E
Bioact Mater; 2022 Oct; 16():15-26. PubMed ID: 35386333
[TBL] [Abstract][Full Text] [Related]
13. Static and Dynamic Stress Analysis of Standard- and Narrow-Diameter Implants: A 3D Finite Element Analysis.
Sahin SC
Int J Oral Maxillofac Implants; 2020; 35(4):e58-e68. PubMed ID: 32724919
[TBL] [Abstract][Full Text] [Related]
14. Mechanical behavior of dental implants in different positions in the rehabilitation of the anterior maxilla.
Corrêa CB; Margonar R; Noritomi PY; Vaz LG
J Prosthet Dent; 2014 Apr; 111(4):301-9. PubMed ID: 24355510
[TBL] [Abstract][Full Text] [Related]
15. Finite element analysis of a one-piece zirconia implant in anterior single tooth implant applications.
Talmazov G; Veilleux N; Abdulmajeed A; Bencharit S
PLoS One; 2020; 15(2):e0229360. PubMed ID: 32092128
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical evaluation of anterior implants associated with titanium and zirconia abutments and monotype zirconia implants.
Brandão de Holanda KA; Armini Caldas R; Amaral M; da Silva Concilio LR; Pino Vitti R
J Prosthodont Res; 2021 Feb; 65(1):73-77. PubMed ID: 32938877
[TBL] [Abstract][Full Text] [Related]
17. Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy-3D non-linear finite element analysis.
Tretto PHW; Dos Santos MBF; Spazzin AO; Pereira GKR; Bacchi A
Comput Methods Biomech Biomed Engin; 2020 Jun; 23(8):372-383. PubMed ID: 32116034
[TBL] [Abstract][Full Text] [Related]
18. Conjoint corrosion and wear in titanium alloys.
Khan MA; Williams RL; Williams DF
Biomaterials; 1999 Apr; 20(8):765-72. PubMed ID: 10353659
[TBL] [Abstract][Full Text] [Related]
19. Titanium alloys: in vitro biological analyzes on biofilm formation, biocompatibility, cell differentiation to induce bone formation, and immunological response.
Mello DCR; de Oliveira JR; Cairo CAA; Ramos LSB; Vegian MRDC; de Vasconcellos LGO; de Oliveira FE; de Oliveira LD; de Vasconcellos LMR
J Mater Sci Mater Med; 2019 Sep; 30(9):108. PubMed ID: 31535222
[TBL] [Abstract][Full Text] [Related]
20. Influence of the Elastic Modulus on the Osseointegration of Dental Implants.
Brizuela A; Herrero-Climent M; Rios-Carrasco E; Rios-Santos JV; Pérez RA; Manero JM; Gil Mur J
Materials (Basel); 2019 Mar; 12(6):. PubMed ID: 30934553
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]