These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 36560191)

  • 1. Validation of Novel Ultrasonic Phased Array Borehole Probe by Using Simulation and Measurement.
    Prabhakara P; Mielentz F; Stolpe H; Behrens M; Lay V; Niederleithinger E
    Sensors (Basel); 2022 Dec; 22(24):. PubMed ID: 36560191
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enhancing the Performance of a Large Aperture Ultrasound System (LAUS): A Combined Approach of Simulation and Measurement for Transmitter-Receiver Optimization.
    Prabhakara P; Lay V; Mielentz F; Niederleithinger E; Behrens M
    Sensors (Basel); 2023 Dec; 24(1):. PubMed ID: 38202962
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonic Quality Assurance at Magnesia Shotcrete Sealing Structures.
    Lay V; Effner U; Niederleithinger E; Arendt J; Hofmann M; Kudla W
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433315
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a 16-Channel Broadband Piezoelectric Micro Ultrasonic Transducer Array Probe for Pipeline Butt-Welded Defect Detection.
    Li B; Sun C; Xin S; Luo M; Hei C; Du G; Feng A
    Sensors (Basel); 2022 Sep; 22(19):. PubMed ID: 36236232
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simulation and data reconstruction for NDT phased array techniques.
    Chatillon S; de Roumilly L; Porre J; Poidevin C; Calmon P
    Ultrasonics; 2006 Dec; 44 Suppl 1():e951-5. PubMed ID: 17070564
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Excitation of ultrasonic Lamb waves using a phased array system with two array probes: phantom and in vitro bone studies.
    Nguyen KC; Le LH; Tran TN; Sacchi MD; Lou EH
    Ultrasonics; 2014 Jul; 54(5):1178-85. PubMed ID: 24074751
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonparaxial multi-Gaussian beam models and measurement models for phased array transducers.
    Zhao X; Gang T
    Ultrasonics; 2009 Jan; 49(1):126-30. PubMed ID: 18774152
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physical Simulation of Ultrasonic Imaging Logging Response.
    Lu J; Han J; Wu J; Che X; Qiao W; Wang J; Chen X
    Sensors (Basel); 2022 Dec; 22(23):. PubMed ID: 36502123
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling the radiation of ultrasonic phased-array transducers with Gaussian beams.
    Huang R; Schmerr LW; Sedov A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Dec; 55(12):2692-702. PubMed ID: 19126493
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Modeling and simulation of responses from ultrasonic linear phased array].
    He W; Zhu Y; Wang Y; He L; Lai S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Oct; 29(5):846-50. PubMed ID: 23198419
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcranial Ultrasonic Focusing by a Phased Array Based on Micro-CT Images.
    Yin Y; Yan S; Huang J; Zhang B
    Sensors (Basel); 2023 Dec; 23(24):. PubMed ID: 38139547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatial-angular compounding for elastography using beam steering on linear array transducers.
    Rao M; Chen Q; Shi H; Varghese T
    Med Phys; 2006 Mar; 33(3):618-26. PubMed ID: 16878565
    [TBL] [Abstract][Full Text] [Related]  

  • 13. One-dimension frequency-wavenumber-domain based model for ultrasonic waves generated by dual-array transducers.
    Kubrusly AC; Kang L; Dixon S
    Ultrasonics; 2022 Aug; 124():106772. PubMed ID: 35660201
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound nondestructive evaluation (NDE) imaging with transducer arrays and adaptive processing.
    Li M; Hayward G
    Sensors (Basel); 2012; 12(1):42-54. PubMed ID: 22368457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasonic non-destructive testing of pieces of complex geometry with a flexible phased array transducer.
    Chatillon S; Cattiaux G; Serre M; Roy O
    Ultrasonics; 2000 Mar; 38(1-8):131-4. PubMed ID: 10829644
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simulation of ultrasound two-dimensional array transducers using a frequency domain model.
    Rao M; Varghese T; Zagzebski JA
    Med Phys; 2008 Jul; 35(7):3162-9. PubMed ID: 18697541
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new omnidirectional shear horizontal wave transducer using face-shear (d
    Miao H; Huan Q; Wang Q; Li F
    Ultrasonics; 2017 Feb; 74():167-173. PubMed ID: 27816871
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of conformal map theory for design of 2-D ultrasonic array structure for NDT imaging application: a feasibility study.
    Ramadas SN; Jackson JC; Dziewierz J; O'Leary R; Gachagan A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Mar; 61(3):496-504. PubMed ID: 24569253
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A high-sensitivity and long-distance structural health monitoring system based on bidirectional SH wave phased array.
    Huan Q; Chen M; Li F
    Ultrasonics; 2020 Dec; 108():106190. PubMed ID: 32526528
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Adapting the Time-Domain Synthetic Aperture Focusing Technique (T-SAFT) to Laser Ultrasonics for Imaging the Subsurface Defects.
    Karuppasamy SS; Yang CH
    Sensors (Basel); 2023 Sep; 23(19):. PubMed ID: 37836866
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.