These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 36561150)

  • 1. Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study.
    Kozaki T; Hashizume H; Oka H; Ohashi S; Kumano Y; Yamamoto E; Minamide A; Yukawa Y; Iwasaki H; Tsutsui S; Takami M; Nakata K; Taniguchi T; Fukui D; Nishiyama D; Yamanaka M; Tamai H; Taiji R; Murata S; Murata A; Yamada H
    Spine Surg Relat Res; 2022 Nov; 6(6):681-688. PubMed ID: 36561150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of Lumbar Fusion and Pelvic Fixation Rigidity on Hip Joint Stress: A Finite Element Analysis.
    Kozaki T; Lundberg HJ; Mell SP; Samartzis D; Kawakami M; Yamada H; Inoue N; An HS
    Spine (Phila Pa 1976); 2023 Oct; 48(20):E355-E361. PubMed ID: 37530119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lumbar fusion leads to increases in angular motion and stress across sacroiliac joint: a finite element study.
    Ivanov AA; Kiapour A; Ebraheim NA; Goel V
    Spine (Phila Pa 1976); 2009 Mar; 34(5):E162-9. PubMed ID: 19247155
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Effect of L
    Cai XY; Sun MS; Huang YP; Liu ZX; Liu CJ; Du CF; Yang Q
    Orthop Surg; 2020 Jun; 12(3):917-930. PubMed ID: 32476282
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.
    Lindsey DP; Kiapour A; Yerby SA; Goel VK
    Int J Spine Surg; 2015; 9():64. PubMed ID: 26767156
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Changes of Adjacent and Fixed Segments Through Cortical Bone Trajectory Screw Fixation versus Traditional Trajectory Screw Fixation in the Lumbar Spine: A Finite Element Analysis.
    Zhang L; Li HM; Zhang R; Zhang H; Shen CL
    World Neurosurg; 2021 Jul; 151():e447-e456. PubMed ID: 33895371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study.
    Ambati DV; Wright EK; Lehman RA; Kang DG; Wagner SC; Dmitriev AE
    Spine J; 2015 Aug; 15(8):1812-22. PubMed ID: 24983669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine.
    Harris BM; Hilibrand AS; Savas PE; Pellegrino A; Vaccaro AR; Siegler S; Albert TJ
    Spine (Phila Pa 1976); 2004 Feb; 29(4):E65-70. PubMed ID: 15094547
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Internal and external responses of anterior lumbar/lumbosacral fusion: nonlinear finite element analysis.
    Guan Y; Yoganandan N; Maiman DJ; Pintar FA
    J Spinal Disord Tech; 2008 Jun; 21(4):299-304. PubMed ID: 18525492
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical analysis of motion following sacroiliac joint fusion using lateral sacroiliac screws with or without lumbosacral instrumented fusion.
    Dall BE; Eden SV; Cho W; Karkenny A; Brooks DM; Hayward GM; Moldavsky M; Yandamuri S; Bucklen BS
    Clin Biomech (Bristol, Avon); 2019 Aug; 68():182-189. PubMed ID: 31234032
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects on hip stress following sacroiliac joint fixation: A finite element study.
    Joukar A; Chande RD; Carpenter RD; Lindsey DP; Erbulut DU; Yerby SA; Duhon B; Goel VK
    JOR Spine; 2019 Dec; 2(4):e1067. PubMed ID: 31891117
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adding sacral anchors through an S1 alar screw and multirod construct as a strategy for lumbosacral junction augmentation: an in vitro comparison to S1 pedicle screws alone with sacroiliac fixation.
    Pan A; Yang H; Hai Y; Liu Y; Zhang X; Ding H; Li Y; Lu H; Ding Z; Xu Y; Pei B
    J Neurosurg Spine; 2023 Jan; 38(1):107-114. PubMed ID: 36029265
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Segmental motion adjacent to an instrumented lumbar fusion: the effect of extension of fusion to the sacrum.
    Untch C; Liu Q; Hart R
    Spine (Phila Pa 1976); 2004 Nov; 29(21):2376-81. PubMed ID: 15507798
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Comparison of Stand-Alone and Bilateral Pedicle Screw Fixation for Oblique Lumbar Interbody Fusion Surgery-A Finite Element Analysis.
    Fang G; Lin Y; Wu J; Cui W; Zhang S; Guo L; Sang H; Huang W
    World Neurosurg; 2020 Sep; 141():e204-e212. PubMed ID: 32502627
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of lordosis on adjacent levels after lumbar interbody fusion, before and after removal of the spinal fixator: a finite element analysis.
    Tsuang FY; Tsai JC; Lai DM
    BMC Musculoskelet Disord; 2019 Oct; 20(1):470. PubMed ID: 31651312
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multiple Points of Pelvic Fixation: Stacked S2-Alar-Iliac Screws (S2AI) or Concurrent S2AI and Open Sacroiliac Joint Fusion with Triangular Titanium Rod.
    Polly DW; Holton KJ; Soriano PO; Sembrano JN; Martin CT; Hendrickson NR; Jones KE
    JBJS Essent Surg Tech; 2022; 12(4):e21.00044. PubMed ID: 36743282
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical changes of degenerated adjacent segment and intact lumbar spine after lumbosacral topping-off surgery: a three-dimensional finite element analysis.
    Cao L; Liu Y; Mei W; Xu J; Zhan S
    BMC Musculoskelet Disord; 2020 Feb; 21(1):104. PubMed ID: 32061252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does oblique lumbar interbody fusion promote adjacent degeneration in degenerative disc disease: A finite element analysis.
    Du CF; Cai XY; Gui W; Sun MS; Liu ZX; Liu CJ; Zhang CQ; Huang YP
    Comput Biol Med; 2021 Jan; 128():104122. PubMed ID: 33248365
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Adjacent segment degeneration after lumbosacral fusion in spondylolisthesis: a retrospective radiological and clinical analysis].
    Zencica P; Chaloupka R; Hladíková J; Krbec M
    Acta Chir Orthop Traumatol Cech; 2010 Apr; 77(2):124-30. PubMed ID: 20447355
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study.
    Casaroli G; Galbusera F; Chande R; Lindsey D; Mesiwala A; Yerby S; Brayda-Bruno M
    Eur Spine J; 2019 Jul; 28(7):1724-1732. PubMed ID: 31093749
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.