These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 36575941)

  • 21. Overcoming the current issues surrounding device leads: reducing the complications during extraction.
    Bongiorni MG; Segreti L; Di Cori A; Zucchelli G; Paperini L; Viani S; Soldati E
    Expert Rev Med Devices; 2017 Jun; 14(6):469-480. PubMed ID: 28521596
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Outcome of transvenous lead extraction in nonagenarians: A single-center retrospective study.
    Komatsu T; Okada A; Shoda M; Tanaka K; Kobayashi H; Oguchi Y; Saigusa T; Ebisawa S; Motoki H; Kuwahara K
    Pacing Clin Electrophysiol; 2024 Oct; 47(10):1293-1299. PubMed ID: 39161131
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Efficacy and safety of transvenous lead extraction in 108 consecutive patients: a single-centre experience.
    Monsefi N; Waraich HS; Vamos M; Erath J; Sirat S; Moritz A; Hohnloser SH
    Interact Cardiovasc Thorac Surg; 2019 May; 28(5):704-708. PubMed ID: 30597017
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction.
    Aytemir K; Yorgun H; Canpolat U; Şahiner ML; Kaya EB; Evranos B; Özer N
    Europace; 2016 Jul; 18(7):1043-8. PubMed ID: 26467403
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Safety and In-Hospital Outcomes of Transvenous Lead Extraction for Cardiac Implantable Device-Related Infections: Analysis of 13 Years of Inpatient Data in the United States.
    Hosseini SM; Rozen G; Kaadan MI; Galvin J; Ruskin JN
    JACC Clin Electrophysiol; 2019 Dec; 5(12):1450-1458. PubMed ID: 31857046
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience.
    Zabek A; Malecka B; Haberka K; Boczar K; Pfitzner R; Debski M; Lelakowski J
    Acta Cardiol; 2015 Dec; 70(6):685-92. PubMed ID: 26717217
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience.
    Zhou X; Ze F; Li D; Wang L; Guo J; Li X
    Clin Cardiol; 2020 Apr; 43(4):386-393. PubMed ID: 31904110
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reimplantation and long-term mortality after transvenous lead extraction in a high-risk, single-center cohort.
    Zsigmond EJ; Miklos M; Vida A; Benak A; Makai A; Schvartz N; Klausz G; Hegedus Z; Bogats G; Saghy L; Vamos M
    J Interv Card Electrophysiol; 2023 Jun; 66(4):847-855. PubMed ID: 33723694
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Extraction of infected cardiac implantable electronic devices and the need for subsequent re-implantation.
    Döring M; Hienzsch L; Ebert M; Lucas J; Dagres N; Kühl M; Hindricks G; Knopp H; Richter S
    Int J Cardiol; 2020 Jun; 309():84-91. PubMed ID: 31973885
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Clinical predictors of incomplete coronary sinus lead removal during transvenous lead extraction in patients with cardiac resynchronization therapy.
    Hayashi K; Younis A; Callahan T; Baranowski B; Martin DO; Nakhla S; Wilkoff BL
    Heart Rhythm; 2023 Jun; 20(6):872-878. PubMed ID: 36933853
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transvenous extraction of permanent pacemaker and defibrillator leads: Reduced procedural complexity and higher procedural success rates in patients with infective versus noninfective indications.
    Archontakis S; Pirounaki M; Aznaouridis K; Karageorgopoulos D; Sideris K; Tolios P; Triantafyllou K; Gatzoulis K; Tousoulis D; Sideris S
    J Cardiovasc Electrophysiol; 2021 Feb; 32(2):491-499. PubMed ID: 33345428
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions.
    Brunner MP; Cronin EM; Duarte VE; Yu C; Tarakji KG; Martin DO; Callahan T; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2014 May; 11(5):799-805. PubMed ID: 24444444
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Epicardial pacemaker as a bridge for pacemaker-dependent patients undergoing explantation of infected cardiac implantable electronic devices.
    Al-Maisary SSA; Romano G; Karck M; De Simone R
    J Card Surg; 2019 Jun; 34(6):424-427. PubMed ID: 31017328
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study.
    Ahmed FZ; Fullwood C; Zaman M; Qamruddin A; Cunnington C; Mamas MA; Sandoe J; Motwani M; Zaidi A
    PLoS One; 2019; 14(1):e0206611. PubMed ID: 30601808
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Risk Factors Predicting Complications of Transvenous Lead Extraction.
    Jacheć W; Polewczyk A; Polewczyk M; Tomasik A; Janion M; Kutarski A
    Biomed Res Int; 2018; 2018():8796704. PubMed ID: 30662917
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Unrecognized venous injuries after cardiac implantable electronic device transvenous lead extraction.
    Tarakji KG; Saliba W; Markabawi D; Rodriguez ER; Krauthammer Y; Brunner MP; Hussein AA; Baranowski B; Cantillon DJ; Kanj M; Niebauer M; Rickard J; Callahan T; Shao M; Martin DO; Wazni OM; Wilkoff BL; Tan CD
    Heart Rhythm; 2018 Mar; 15(3):318-325. PubMed ID: 29141184
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Lead extraction: The road to successful cardiac resynchronization therapy.
    Maciąg A; Syska P; Sterliński M; Przybylski A; Sitkowska E; Oręziak A; Bilińska M; Kuśmierczyk M; Szwed H
    Cardiol J; 2015; 22(2):188-93. PubMed ID: 25299498
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Long-term mortality after transvenous lead extraction.
    Maytin M; Jones SO; Epstein LM
    Circ Arrhythm Electrophysiol; 2012 Apr; 5(2):252-7. PubMed ID: 22362891
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cardiac tamponade as an inherent but potentially nonfatal complication of transvenous lead extraction: Experience with 1126 procedures performed using mechanical tools.
    Nowosielecka D; Tułecki Ł; Jacheć W; Polewczyk A; Tomków K; Stefańczyk P; Bródka J; Kutarski A
    J Cardiovasc Electrophysiol; 2022 Dec; 33(12):2625-2639. PubMed ID: 36054327
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.