These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 36593536)

  • 1. Re-Evaluation of Patient-Sourced Radiation Doses in PET/CT.
    Şenışık AM; Kökkülünk HT; Yüksel M
    Curr Radiopharm; 2023; 16(2):163-169. PubMed ID: 36593536
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of Radiation Exposure to Workers During [
    Al-Aamria M; Al-Balushia N; Bailey D
    J Med Imaging Radiat Sci; 2019 Dec; 50(4):565-570. PubMed ID: 31447232
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiation exposure of patients and personnel from a PET/CT procedure with 18F-FDG.
    Leide-Svegborn S
    Radiat Prot Dosimetry; 2010; 139(1-3):208-13. PubMed ID: 20167792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Instantaneous exposure to nuclear medicine staff involved in PET-CT imaging in developing countries: experience from a tertiary care centre in India.
    Kumar S; Pandey AK; Sharma P; Shamim SA; Malhotra A; Kumar R
    Jpn J Radiol; 2012 May; 30(4):291-5. PubMed ID: 22246804
    [TBL] [Abstract][Full Text] [Related]  

  • 5. More advantages in detecting bone and soft tissue metastases from prostate cancer using
    Pianou NK; Stavrou PZ; Vlontzou E; Rondogianni P; Exarhos DN; Datseris IE
    Hell J Nucl Med; 2019; 22(1):6-9. PubMed ID: 30843003
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel weight-based dose threshold for 18F-NaF PET-CT imaging using advanced PET-CT systems: a potential tool for reducing radiation burden.
    Marafi F; Esmail A; Rasheed R; Alkandari F; Usmani S
    Nucl Med Commun; 2017 Sep; 38(9):764-770. PubMed ID: 28723715
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of Radiation Exposure Dose for Nuclear Medicine Workers from
    Al-Esaei AM; Khalil MM; El Shazly RM; Kany AMI; Saleh EE; Elmaghraby S
    Curr Radiopharm; 2022; 15(4):320-326. PubMed ID: 35422232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reassessment of Radiation Exposure From Bone Scintigraphy.
    Tanyildizi-Kökkülünk H; Şenişik AM; Yüksel M
    Curr Drug Metab; 2023; 24(11):763-769. PubMed ID: 38141186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic reference levels for
    Alkhybari EM; McEntee MF; Brennan PC; Willowson KP; Kench PL
    J Med Imaging Radiat Oncol; 2019 Jun; 63(3):291-299. PubMed ID: 30770654
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiation protection for accompanying person and radiation workers in PET/CT.
    Demir M; Demir B; Sayman H; Sager S; Sabbir Ahmed A; Uslu I
    Radiat Prot Dosimetry; 2011 Nov; 147(4):528-32. PubMed ID: 21183551
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nuclear medicine staff exposure to ionising radiation in
    Pavičar B; Davidović J; Petrović B; Vuleta G; Trivić S; Šajinović V; Egeljić-Mihailović N; Todorović N; Predojević B
    Arh Hig Rada Toksikol; 2021 Sep; 72(3):216-224. PubMed ID: 34587667
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012.
    Johnsen B; Fasmer KE; Boye K; Rosendahl K; Trovik C; Biermann M; Aukland SM
    Pediatr Radiol; 2017 Jan; 47(1):82-88. PubMed ID: 27815616
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of patient dose in (18)F-FDG and (18)F-FDOPA PET/CT examinations.
    Kaushik A; Jaimini A; Tripathi M; D'Souza M; Sharma R; Mishra AK; Mondal A; Dwarakanath BS
    J Cancer Res Ther; 2013; 9(3):477-83. PubMed ID: 24125986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patients undergoing multiple
    Indrakanti S; Li X; Rehani MM
    Br J Radiol; 2022 Jul; 95(1135):20211225. PubMed ID: 35348374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT.
    Willowson KP; Bailey EA; Bailey DL
    Australas Phys Eng Sci Med; 2012 Mar; 35(1):49-53. PubMed ID: 22160927
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An Australian local diagnostic reference level for paediatric whole-body
    Alkhybari EM; McEntee MF; Willowson KP; Brennan PC; Kitsos T; Kench PL
    Br J Radiol; 2019 Apr; 92(1096):20180879. PubMed ID: 30653334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Patient-specific radiation dose for Chinese pediatric patients undergoing whole-body PET/CT examinations.
    Jia H; Xue M; Li X; Zhuang M; Xie T
    Phys Med Biol; 2024 Jun; 69(12):. PubMed ID: 38776955
    [No Abstract]   [Full Text] [Related]  

  • 18. Radiation dosimetry of 18F-FDG PET/CT: incorporating exam-specific parameters in dose estimates.
    Quinn B; Dauer Z; Pandit-Taskar N; Schoder H; Dauer LT
    BMC Med Imaging; 2016 Jun; 16(1):41. PubMed ID: 27317478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies.
    Quinn BM; Gao Y; Mahmood U; Pandit-Taskar N; Behr G; Zanzonico P; Dauer LT
    BMC Med Imaging; 2020 Jan; 20(1):9. PubMed ID: 31996149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation dose to nuclear medicine technologists when operating PET/MR compared with PET/CT.
    Soret M; Maisonobe JA; Payen S; Gaubert A; Brunel S; Bergeret S; Berenbaum A; Hubert E; Kas A
    J Radiol Prot; 2022 Apr; 42(2):. PubMed ID: 35296565
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.