221 related articles for article (PubMed ID: 36596654)
1. Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients.
Blanchet MA; Mercier G; Delobel A; Nayet E; Bouchard PA; Simard S; L'Her E; Branson RD; Lellouche F
Respir Care; 2023 May; 68(5):565-574. PubMed ID: 36596654
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
Feiner JR; Bickler PE; Mannheimer PD
Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
[TBL] [Abstract][Full Text] [Related]
3. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
[TBL] [Abstract][Full Text] [Related]
4. Effects of skin pigmentation on pulse oximeter accuracy at low saturation.
Bickler PE; Feiner JR; Severinghaus JW
Anesthesiology; 2005 Apr; 102(4):715-9. PubMed ID: 15791098
[TBL] [Abstract][Full Text] [Related]
5. Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion.
Louie A; Feiner JR; Bickler PE; Rhodes L; Bernstein M; Lucero J
Anesthesiology; 2018 Mar; 128(3):520-530. PubMed ID: 29200008
[TBL] [Abstract][Full Text] [Related]
6. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender.
Feiner JR; Severinghaus JW; Bickler PE
Anesth Analg; 2007 Dec; 105(6 Suppl):S18-S23. PubMed ID: 18048893
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of pulse oximeters at low oxygen saturations in children with congenital cyanotic heart disease: An observational study.
Kim EH; Lee JH; Song IK; Kim HS; Jang YE; Yoo S; Kim JT
Paediatr Anaesth; 2019 Jun; 29(6):597-603. PubMed ID: 30938906
[TBL] [Abstract][Full Text] [Related]
8. Reliability of conventional and new pulse oximetry in neonatal patients.
Hay WW; Rodden DJ; Collins SM; Melara DL; Hale KA; Fashaw LM
J Perinatol; 2002; 22(5):360-6. PubMed ID: 12082469
[TBL] [Abstract][Full Text] [Related]
9. Low Perfusion and Missed Diagnosis of Hypoxemia by Pulse Oximetry in Darkly Pigmented Skin: A Prospective Study.
Gudelunas MK; Lipnick M; Hendrickson C; Vanderburg S; Okunlola B; Auchus I; Feiner JR; Bickler PE
Anesth Analg; 2024 Mar; 138(3):552-561. PubMed ID: 38109495
[TBL] [Abstract][Full Text] [Related]
10. Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children.
Brouillette RT; Lavergne J; Leimanis A; Nixon GM; Ladan S; McGregor CD
Anesth Analg; 2002 Jan; 94(1 Suppl):S47-53. PubMed ID: 11900039
[TBL] [Abstract][Full Text] [Related]
11. The Use of Wearable Pulse Oximeters in the Prompt Detection of Hypoxemia and During Movement: Diagnostic Accuracy Study.
Santos M; Vollam S; Pimentel MA; Areia C; Young L; Roman C; Ede J; Piper P; King E; Harford M; Shah A; Gustafson O; Tarassenko L; Watkinson P
J Med Internet Res; 2022 Feb; 24(2):e28890. PubMed ID: 35166690
[TBL] [Abstract][Full Text] [Related]
12. Comparison of two new generation pulse oximeters with arterial oxygen saturation in critically ill children.
Jose B; Lodha R; Kabra SK
Indian J Pediatr; 2014 Dec; 81(12):1297-301. PubMed ID: 24627281
[TBL] [Abstract][Full Text] [Related]
13. Performance of the new SmartCardia wireless, wearable oximeter: a comparison with arterial SaO2 in healthy volunteers.
Rincon F; Pidoux J; Murali S; Goy JJ
BMC Anesthesiol; 2022 Mar; 22(1):77. PubMed ID: 35331157
[TBL] [Abstract][Full Text] [Related]
14. The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia.
Barker SJ; Hyatt J; Shah NK; Kao YJ
Anesthesiology; 1993 Aug; 79(2):248-54. PubMed ID: 8342837
[TBL] [Abstract][Full Text] [Related]
15. Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review.
Aoki KC; Barrant M; Gai MJ; Handal M; Xu V; Mayrovitz HN
Cureus; 2023 Sep; 15(9):e46078. PubMed ID: 37900526
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
[TBL] [Abstract][Full Text] [Related]
17. Pulse oximeter performance during desaturation and resaturation: a comparison of seven models.
Trivedi NS; Ghouri AF; Lai E; Shah NK; Barker SJ
J Clin Anesth; 1997 May; 9(3):184-8. PubMed ID: 9172023
[TBL] [Abstract][Full Text] [Related]
18. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.
Bickler PE; Feiner JR; Rollins MD
Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027
[TBL] [Abstract][Full Text] [Related]
19. A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals.
Pilcher J; Ploen L; McKinstry S; Bardsley G; Chien J; Howard L; Lee S; Beckert L; Swanney M; Weatherall M; Beasley R
BMC Pulm Med; 2020 Jan; 20(1):7. PubMed ID: 31918697
[TBL] [Abstract][Full Text] [Related]
20. The effects of motion on the performance of pulse oximeters in volunteers (revised publication).
Barker SJ; Shah NK
Anesthesiology; 1997 Jan; 86(1):101-8. PubMed ID: 9009945
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]