These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 36599876)

  • 1. Learning-based physical models of room-temperature semiconductor detectors with reduced data.
    Banerjee S; Rodrigues M; Ballester M; Vija AH; Katsaggelos AK
    Sci Rep; 2023 Jan; 13(1):168. PubMed ID: 36599876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Charge Sharing and Charge Loss in High-Flux Capable Pixelated CdZnTe Detectors.
    Koch-Mehrin KAL; Bugby SL; Lees JE; Veale MC; Wilson MD
    Sensors (Basel); 2021 May; 21(9):. PubMed ID: 34066764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spectral resolution and high-flux capability tradeoffs in CdTe detectors for clinical CT.
    Hsieh SS; Rajbhandary PL; Pelc NJ
    Med Phys; 2018 Apr; 45(4):1433-1443. PubMed ID: 29418004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo investigation of charge-transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applications.
    Myronakis ME; Darambara DG
    Med Phys; 2011 Jan; 38(1):455-67. PubMed ID: 21361214
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.
    Sordo SD; Abbene L; Caroli E; Mancini AM; Zappettini A; Ubertini P
    Sensors (Basel); 2009; 9(5):3491-526. PubMed ID: 22412323
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
    Barber WC; Wessel JC; Nygard E; Iwanczyk JS
    Nucl Instrum Methods Phys Res A; 2015 Jun; 784():531-537. PubMed ID: 25937684
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation of charge transport in pixelated CdTe.
    Kolstein M; Ariño G; Chmeissani M; De Lorenzo G
    J Instrum; 2014 Dec; 9():C12027. PubMed ID: 25729404
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Energy Recovery of Multiple Charge Sharing Events in Room Temperature Semiconductor Pixel Detectors.
    Buttacavoli A; Gerardi G; Principato F; Mirabello M; Cascio D; Raso G; Bettelli M; Zappettini A; Seller P; Veale MC; Abbene L
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34070426
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Room-temperature performance of 3 mm-thick cadmium-zinc-telluride pixel detectors with sub-millimetre pixelization.
    Buttacavoli A; Principato F; Gerardi G; Bettelli M; Sarzi Amadè N; Zappettini A; Seller P; Veale MC; Fox O; Sawhney K; Abbene L
    J Synchrotron Radiat; 2020 Sep; 27(Pt 5):1180-1189. PubMed ID: 32876592
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 3-D Spatial Resolution of 350
    Yin Y; Chen X; Wu H; Komarov S; Garson A; Li Q; Guo Q; Krawczynski H; Meng LJ; Tai YC
    IEEE Trans Nucl Sci; 2013 Feb; 60(1):9-15. PubMed ID: 28250476
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Signal formation and decay in CdTe x-ray detectors under intense irradiation.
    Jahnke A; Matz R
    Med Phys; 1999 Jan; 26(1):38-48. PubMed ID: 9949396
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CdZnTe array detectors for synchrotron radiation applications.
    Yoo SS; Jennings G; Montano PA
    J Synchrotron Radiat; 1998 Nov; 5(Pt 6):1332-6. PubMed ID: 16687845
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Progress in the development of CdZnTe unipolar detectors for different anode geometries and data corrections.
    Zhang Q; Zhang C; Lu Y; Yang K; Ren Q
    Sensors (Basel); 2013 Feb; 13(2):2447-74. PubMed ID: 23429509
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
    Shikhaliev PM; Fritz SG; Chapman JW
    Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A 2D 4×4 Channel Readout ASIC for Pixelated CdTe Detectors for Medical Imaging Applications.
    Macias-Montero JG; Sarraj M; Chmeissani M; Martínez R; Puigdengoles C
    IEEE Trans Nucl Sci; 2015 Oct; 62(5 Pt 2):2327-2333. PubMed ID: 26744545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement to the Carrier Transport Properties of CdZnTe Detector Using Sub-Band-Gap Light Radiation.
    Luo X; Zha G; Xu L; Jie W
    Sensors (Basel); 2019 Jan; 19(3):. PubMed ID: 30708996
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incomplete Charge Collection at Inter-Pixel Gap in Low- and High-Flux Cadmium Zinc Telluride Pixel Detectors.
    Buttacavoli A; Principato F; Gerardi G; Cascio D; Raso G; Bettelli M; Zappettini A; Seller P; Veale MC; Abbene L
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved x-ray spectroscopy with room temperature CZT detectors.
    Fritz SG; Shikhaliev PM; Matthews KL
    Phys Med Biol; 2011 Sep; 56(17):5735-51. PubMed ID: 21841213
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of CdZnTeSe as a high-quality gamma-ray spectroscopic material with better compositional homogeneity and reduced defects.
    Roy UN; Camarda GS; Cui Y; Gul R; Yang G; Zazvorka J; Dedic V; Franc J; James RB
    Sci Rep; 2019 May; 9(1):7303. PubMed ID: 31086249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors.
    Roy UN; Mundle RM; Camarda GS; Cui Y; Gul R; Hossain A; Yang G; Pradhan AK; James RB
    Sci Rep; 2016 May; 6():26384. PubMed ID: 27216387
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.