41. Thermal Damage Done to Bone by Burring and Sawing With and Without Irrigation in Knee Arthroplasty. Tawy GF; Rowe PJ; Riches PE J Arthroplasty; 2016 May; 31(5):1102-8. PubMed ID: 26718777 [TBL] [Abstract][Full Text] [Related]
42. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill. Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154 [TBL] [Abstract][Full Text] [Related]
43. Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones. Singh RP; Pandey PM; Behera C; Mridha AR Proc Inst Mech Eng H; 2020 Aug; 234(8):829-842. PubMed ID: 32490719 [TBL] [Abstract][Full Text] [Related]
44. Orthopaedic bone drills-can they be improved? Temperature changes near the drilling face. Natali C; Ingle P; Dowell J J Bone Joint Surg Br; 1996 May; 78(3):357-62. PubMed ID: 8636166 [TBL] [Abstract][Full Text] [Related]
45. Thermal Osteonecrosis Caused by Bone Drilling in Orthopedic Surgery: A Literature Review. Timon C; Keady C Cureus; 2019 Jul; 11(7):e5226. PubMed ID: 31565628 [TBL] [Abstract][Full Text] [Related]
46. Numerical and Experimental Analyses on the Temperature Distribution in the Dental Implant Preparation Area when Using a Surgical Guide. Liu YF; Wu JL; Zhang JX; Peng W; Liao WQ J Prosthodont; 2018 Jan; 27(1):42-51. PubMed ID: 27078175 [TBL] [Abstract][Full Text] [Related]
47. Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899 [TBL] [Abstract][Full Text] [Related]
48. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants. Bulloch SE; Olsen RG; Bulloch B Int J Oral Maxillofac Implants; 2012; 27(6):1456-60. PubMed ID: 23189297 [TBL] [Abstract][Full Text] [Related]
49. Influence of a resilient, hard-carbon thin film on drilling efficiency and thermogenesis. Gasiorowski JC; Richardson DW; Boston RC; Schaer TP Vet Surg; 2011 Oct; 40(7):875-80. PubMed ID: 22380671 [TBL] [Abstract][Full Text] [Related]
50. Heat generation by ultrasonic bone curette comparing with high-speed drill. Suzuki K; Wanibuchi M; Minamida Y; Akiyama Y; Mikami T; Fujishige M; Yamamura A; Nakagawa T; Mikuni N Acta Neurochir (Wien); 2018 Apr; 160(4):721-725. PubMed ID: 29302755 [TBL] [Abstract][Full Text] [Related]
51. A novel technique to harvest bone autografts with mild local hyperthermia and enhanced osteogenic bone quality: a preclinical study in dogs. Zhou T; Gan Z; Zhang H; Liu Z; Pu Y; Rong M BMC Oral Health; 2023 Nov; 23(1):838. PubMed ID: 37936153 [TBL] [Abstract][Full Text] [Related]
52. Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Augustin G; Davila S; Udiljak T; Vedrina DS; Bagatin D Arch Orthop Trauma Surg; 2009 May; 129(5):703-9. PubMed ID: 18421465 [TBL] [Abstract][Full Text] [Related]
53. In vitro comparison of cortical bone temperature generation between traditional sequential drilling and a newly designed step drill in the equine third metacarpal bone. Bubeck KA; García-López J; Maranda LS Vet Comp Orthop Traumatol; 2009; 22(6):442-7. PubMed ID: 19876527 [TBL] [Abstract][Full Text] [Related]
54. Effect of surgical drill guide on heat generated from implant drilling. Misir AF; Sumer M; Yenisey M; Ergioglu E J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988 [TBL] [Abstract][Full Text] [Related]
55. Temperature changes and chondrocyte death during drilling in a bovine cartilage model and chondroprotection by modified irrigation solutions. Farhan-Alanie MM; Hall AC Int Orthop; 2014 Nov; 38(11):2407-12. PubMed ID: 24859895 [TBL] [Abstract][Full Text] [Related]
56. Numerical evaluation of sequential bone drilling strategies based on thermal damage. Tai BL; Palmisano AC; Belmont B; Irwin TA; Holmes J; Shih AJ Med Eng Phys; 2015 Sep; 37(9):855-61. PubMed ID: 26163230 [TBL] [Abstract][Full Text] [Related]
57. In-vitro experimental analysis and numerical study of temperature in bone drilling. Alam K; Khan M; Muhammad R; Qamar SZ; Silberschmidt VV Technol Health Care; 2015; 23(6):775-83. PubMed ID: 26409522 [TBL] [Abstract][Full Text] [Related]
58. Optimal parameters to avoid thermal necrosis during bone drilling: A finite element analysis. Mediouni M; Schlatterer DR; Khoury A; Von Bergen T; Shetty SH; Arora M; Dhond A; Vaughan N; Volosnikov A J Orthop Res; 2017 Nov; 35(11):2386-2391. PubMed ID: 28181707 [TBL] [Abstract][Full Text] [Related]
59. The effect of drill bit, pin, and wire tip design on drilling. Fincham BM; Jaeblon T J Am Acad Orthop Surg; 2011 Sep; 19(9):574-9. PubMed ID: 21885703 [TBL] [Abstract][Full Text] [Related]
60. Heat and Sound Generation During Implant Osteotomy When Using Different Types of Drills in Artificial and Bovine Bone Blocks. Limmeechokchai S; Kan JY; Rungcharassaeng K; Goodacre CJ; Lozada J; Oyoyo U J Oral Implantol; 2022 Jun; 48(3):187-193. PubMed ID: 34091687 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]