These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 36603221)

  • 21. A new high-density (25 electrodes/mm²) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures.
    Wark HA; Sharma R; Mathews KS; Fernandez E; Yoo J; Christensen B; Tresco P; Rieth L; Solzbacher F; Normann RA; Tathireddy P
    J Neural Eng; 2013 Aug; 10(4):045003. PubMed ID: 23723133
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.
    Oxley TJ; Opie NL; Rind GS; Liyanage K; John SE; Ronayne S; McDonald AJ; Dornom A; Lovell TJH; Mitchell PJ; Bennett I; Bauquier S; Warne LN; Steward C; Grayden DB; Desmond P; Davis SM; O'Brien TJ; May CN
    J Neurosurg; 2018 Apr; 128(4):1020-1027. PubMed ID: 28452616
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Chronic impedance spectroscopy of an endovascular stent-electrode array.
    Opie NL; John SE; Rind GS; Ronayne SM; Grayden DB; Burkitt AN; May CN; O'Brien TJ; Oxley TJ
    J Neural Eng; 2016 Aug; 13(4):046020. PubMed ID: 27378157
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Adaptively Clock-Boosted Auto-Ranging Neural-Interface for Emerging Neuromodulation Applications.
    Pazhouhandeh MR; Amirsoleimani A; Weisspapir I; Carlen P; Genov R
    IEEE Trans Biomed Circuits Syst; 2022 Dec; 16(6):1138-1152. PubMed ID: 36417723
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Signal quality of simultaneously recorded endovascular, subdural and epidural signals are comparable.
    John SE; Opie NL; Wong YT; Rind GS; Ronayne SM; Gerboni G; Bauquier SH; O'Brien TJ; May CN; Grayden DB; Oxley TJ
    Sci Rep; 2018 May; 8(1):8427. PubMed ID: 29849104
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Slim electrodes for improved targeting in deep brain stimulation.
    Villalobos J; McDermott HJ; McNeill P; Golod A; Rathi V; Bauquier SH; Fallon JB
    J Neural Eng; 2020 Mar; 17(2):026008. PubMed ID: 32101807
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cochlear nerve stimulation with a 3-dimensional penetrating electrode array.
    Hillman T; Badi AN; Normann RA; Kertesz T; Shelton C
    Otol Neurotol; 2003 Sep; 24(5):764-8. PubMed ID: 14501454
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Chronic intracortical neural recordings using microelectrode arrays coated with PEDOT-TFB.
    Charkhkar H; Knaack GL; McHail DG; Mandal HS; Peixoto N; Rubinson JF; Dumas TC; Pancrazio JJ
    Acta Biomater; 2016 Mar; 32():57-67. PubMed ID: 26689462
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electrochemical characteristics of ultramicro-dimensioned SIROF electrodes for neural stimulation and recording.
    Ghazavi A; Maeng J; Black M; Salvi S; Cogan SF
    J Neural Eng; 2020 Jan; 17(1):016022. PubMed ID: 31665712
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Novel µECoG Electrode Interface for Comparison of Local and Common Averaged Referenced Signals.
    Williams AJ; Trumpis M; Bent B; Chiang CH; Viventi J
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5057-5060. PubMed ID: 30441477
    [TBL] [Abstract][Full Text] [Related]  

  • 31. PEDOT-CNT-Coated Low-Impedance, Ultra-Flexible, and Brain-Conformable Micro-ECoG Arrays.
    Castagnola E; Maiolo L; Maggiolini E; Minotti A; Marrani M; Maita F; Pecora A; Angotzi GN; Ansaldo A; Boffini M; Fadiga L; Fortunato G; Ricci D
    IEEE Trans Neural Syst Rehabil Eng; 2015 May; 23(3):342-50. PubMed ID: 25073174
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Implantable computer-controlled adaptive multielectrode positioning system.
    Ferrea E; Suriya-Arunroj L; Hoehl D; Thomas U; Gail A
    J Neurophysiol; 2018 Apr; 119(4):1471-1484. PubMed ID: 29187552
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Stable, long-term single-neuronal recording from the rat spinal cord with flexible carbon nanotube fiber electrodes.
    Liu X; Xu Z; Fu X; Liu Y; Jia H; Yang Z; Zhang J; Wei S; Duan X
    J Neural Eng; 2022 Sep; 19(5):. PubMed ID: 36108593
    [No Abstract]   [Full Text] [Related]  

  • 34. Recording Electrical Brain Activity with Novel Stretchable Electrodes Based on Supersonic Cluster Beam Implantation Nanotechnology on Conformable Polymers.
    Gnatkovsky V; Cattalini A; Antonini A; Spreafico L; Saini M; Noè F; Alessi C; Librizzi L; Uva L; Marras CE; de Curtis M; Ferrari S
    Int J Nanomedicine; 2019; 14():10079-10089. PubMed ID: 31920304
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparison of insertion methods for surgical placement of penetrating neural interfaces.
    Thielen B; Meng E
    J Neural Eng; 2021 Apr; 18(4):. PubMed ID: 33845469
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity.
    Chung T; Wang JQ; Wang J; Cao B; Li Y; Pang SW
    J Neural Eng; 2015 Oct; 12(5):056018. PubMed ID: 26394650
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intravenous recording of intracranial, broadband EEG.
    Bower MR; Stead M; Van Gompel JJ; Bower RS; Sulc V; Asirvatham SJ; Worrell GA
    J Neurosci Methods; 2013 Mar; 214(1):21-6. PubMed ID: 23313850
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Long-term
    Jang JW; Kang YN; Seo HW; Kim B; Choe HK; Park SH; Lee MG; Kim S
    J Neural Eng; 2021 Nov; 18(6):. PubMed ID: 34795067
    [No Abstract]   [Full Text] [Related]  

  • 39. Intracortical probe arrays with silicon backbone and microelectrodes on thin polyimide wings enable long-term stable recordings
    Kilias A; Lee YT; Froriep UP; Sielaff C; Moser D; Holzhammer T; Egert U; Fang W; Paul O; Ruther P
    J Neural Eng; 2021 Nov; 18(6):. PubMed ID: 34781276
    [No Abstract]   [Full Text] [Related]  

  • 40. MEMS-Actuated Carbon Fiber Microelectrode for Neural Recording.
    Zoll RS; Schindler CB; Massey TL; Drew DS; Maharbiz MM; Pister KSJ
    IEEE Trans Nanobioscience; 2019 Apr; 18(2):234-239. PubMed ID: 30892226
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.