These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 36606512)

  • 1. Transcatheter closure with a "single lobe" Amplatzer Vascular Plug of a tubular patent ductus arteriosus in a neonate with transposition of the great arteries and heart failure.
    Sharma SR; Michielon G; Fraisse A
    Cardiol Young; 2023 Aug; 33(8):1453-1455. PubMed ID: 36606512
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.
    Karagöz T; Akin A; Ertuğrul I; Aykan HH; Alehan D; Ozer S; Ozkutlu S
    Acta Cardiol; 2012 Dec; 67(6):675-80. PubMed ID: 23393938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter Closure of a Huge Ductus Arteriosus in a Severely Ill Neonate.
    Okada S; Muneuchi J; Nagatomo Y; Yokota C; Ohmura J; Yamamoto J; Watanabe M; Iida C; Shirouzu H; Takahashi Y
    Int Heart J; 2018 Sep; 59(5):1161-1165. PubMed ID: 30012923
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Distensibility of the ductus arteriosus in neonates and young infants undergoing transcatheter closure.
    Nagasawa K; Muneuchi J; Sugitani Y; Ezaki H; Doi H; Furuta T; Kobayashi M; Watanabe M
    Heart Vessels; 2022 Mar; 37(3):513-516. PubMed ID: 34406441
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter retrieval of atrial septal defect and patent ductus arteriosus occluder: a guidance for device retrieval based on comprehensive bench tests.
    Fujii T; Sugiyama H; Kanazawa H; Hara H; Muneuchi J; Yazaki S
    Cardiol Young; 2023 Sep; 33(9):1597-1605. PubMed ID: 36093848
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.
    Morville P; Akhavi A
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):612-617. PubMed ID: 28471089
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Trans-catheter closure of large PDA in adult patients with Amplatzer device: case series.
    Khajali Z; Firouzi A; Ghaderian H; Aliramezany M
    Cardiol Young; 2022 Jan; 32(1):161-164. PubMed ID: 34233780
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure.
    Salam A; Bautista-Rodriguez C; Karsenty C; Bouvaist H; Piccinelli E; Fraisse A
    Arch Cardiovasc Dis; 2022 Mar; 115(3):134-141. PubMed ID: 35249850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter closure of elongated and pulmonary hypertensive patent arterial duct in infants using Amplatzer vascular plug II.
    Jain SM; Pradhan PM; Sen S; Dalvi BV
    Cardiol Young; 2020 Feb; 30(2):243-248. PubMed ID: 31996273
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transposition of the great arteries with intact ventricular septum and patent ductus arteriosus.
    Waldman JD; Paul MH; Newfeld EA; Muster AJ; Idriss FS
    Am J Cardiol; 1977 Feb; 39(2):232-8. PubMed ID: 835481
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].
    Parra-Bravo JR; Apolonio-Martínez A; Estrada-Loza Mde J; Beirana-Palencia LG; Ramírez-Portillo CI
    Arch Cardiol Mex; 2015; 85(3):188-94. PubMed ID: 25700578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transjugular venous approach for Piccolo patent ductus arteriosus closure in a 1.4 kg infant.
    Herron C; Forbes TJ; Kobayashi D
    Cardiol Young; 2022 Jan; 32(1):111-112. PubMed ID: 34865669
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure.
    Tomasulo CE; Gillespie MJ; Munson D; Demkin T; O'Byrne ML; Dori Y; Smith CL; Rome JJ; Glatz AC
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):889-897. PubMed ID: 32339400
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device.
    Prsa M; Ewert P
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):108-11. PubMed ID: 20517997
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder.
    García-Montes JA; Camacho-Castro A; Sandoval-Jones JP; Buendía-Hernández A; Calderón-Colmenero J; Patiño-Bahena E; Zabal C
    Cardiol Young; 2015 Mar; 25(3):491-5. PubMed ID: 24555910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contemporary outcomes of percutaneous closure of patent ductus arteriosus in adolescents and adults.
    P S; Jose J; George OK
    Indian Heart J; 2018; 70(2):308-315. PubMed ID: 29716712
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A successful arterial switch operation in a neonate with transposition of the great arteries and patent ductus arteriosus].
    Shimazaki Y; Iio M; Sakurai M; Hirose O; Sugimoto H; Nakada T
    Nihon Kyobu Geka Gakkai Zasshi; 1986 Oct; 34(10):1857-61. PubMed ID: 3805822
    [No Abstract]   [Full Text] [Related]  

  • 18. Closure of tubular patent ductus arteriosus with the Amplatzer Vascular Plug IV: feasibility and safety.
    Baruteau AE; Lambert V; Riou JY; Angel CY; Belli E; Petit J
    World J Pediatr Congenit Heart Surg; 2015 Jan; 6(1):39-45. PubMed ID: 25548342
    [TBL] [Abstract][Full Text] [Related]  

  • 19. COMPLEMENTARY TECHNIQUES OF PERCUTANEOUS CLOSURE OF DUCTUS ARTERIOSUS USING DETACHABLE COOK COILS AND AMPLATZER DEVICES.
    Yuko-Jowi CA; Okello CA; Mutai L
    East Afr Med J; 2013 Jul; 90(7):214-21. PubMed ID: 26862619
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g.
    Morville P; Douchin S; Bouvaist H; Dauphin C
    Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F198-F201. PubMed ID: 29066474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.