BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 36607792)

  • 1. Thermodilution Assessment of Cardiac Index in Patients With Tricuspid Regurgitation.
    Sternberg ME; Nicolazzi J; Patel MR; Saado J; Kwiatkowski S; Kim R; Bhardwaj H; Gertz ZM
    J Invasive Cardiol; 2023 Mar; 35(3):E122-E125. PubMed ID: 36607792
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation.
    Cigarroa RG; Lange RA; Williams RH; Bedotto JB; Hillis LD
    Am J Med; 1989 Apr; 86(4):417-20. PubMed ID: 2648822
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermodilution vs Estimated Fick Cardiac Output Measurement in Clinical Practice: An Analysis of Mortality From the Veterans Affairs Clinical Assessment, Reporting, and Tracking (VA CART) Program and Vanderbilt University.
    Opotowsky AR; Hess E; Maron BA; Brittain EL; Barón AE; Maddox TM; Alshawabkeh LI; Wertheim BM; Xu M; Assad TR; Rich JD; Choudhary G; Tedford RJ
    JAMA Cardiol; 2017 Oct; 2(10):1090-1099. PubMed ID: 28877293
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Accuracy of Estimation of Cardiac Output by Thermodilution Versus the Fick Method Using Measured Oxygen Uptake.
    Narang N; Thibodeau JT; Parker WF; Grodin JL; Garg S; Tedford RJ; Levine BD; McGuire DK; Drazner MH
    Am J Cardiol; 2022 Aug; 176():58-65. PubMed ID: 35613956
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermodilution and Fick cardiac outputs differ: impact on pulmonary hypertension evaluation.
    Fares WH; Blanchard SK; Stouffer GA; Chang PP; Rosamond WD; Ford HJ; Aris RM
    Can Respir J; 2012; 19(4):261-6. PubMed ID: 22891186
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of solute temperature in the measurement of cardiac output in children using the thermodilution technique.
    Sathanandam S; Kashyap P; Zurakowski D; Bird L; McGhee V; Towbin J; Rush Waller B
    Congenit Heart Dis; 2017 Mar; 12(2):181-187. PubMed ID: 27813342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between Cardiac Output and Pulmonary Vascular Pressure Measured by Indirect Fick and Thermodilution Methods.
    Volodarsky I; Kerzhner K; Haberman D; Cuciuc V; Poles L; Blatt A; Kirzhner E; George J; Gandelman G
    J Pers Med; 2023 Mar; 13(3):. PubMed ID: 36983740
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of VO
    Reiter T; Kerzner J; Fette G; Frantz S; Voelker W; Ertl G; Bauer W; Morbach C; Störk S; Güder G
    Herz; 2024 Feb; 49(1):50-59. PubMed ID: 37439804
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension.
    Hoeper MM; Maier R; Tongers J; Niedermeyer J; Hohlfeld JM; Hamm M; Fabel H
    Am J Respir Crit Care Med; 1999 Aug; 160(2):535-41. PubMed ID: 10430725
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension.
    Yung GL; Fedullo PF; Kinninger K; Johnson W; Channick RN
    Congest Heart Fail; 2004; 10(2 Suppl 2):7-10. PubMed ID: 15073478
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution.
    Balik M; Pachl J; Hendl J
    Intensive Care Med; 2002 Aug; 28(8):1117-21. PubMed ID: 12185434
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermodilution vs estimated Fick cardiac output measurement in an elderly cohort of patients: A single-centre experience.
    Kresoja KP; Faragli A; Abawi D; Paul O; Pieske B; Post H; Alogna A
    PLoS One; 2019; 14(12):e0226561. PubMed ID: 31860679
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of cardiac output using real-time measurement of oxygen consumption during cardiac catheterization in children under 3 years of age.
    Seckeler MD; Hirsch R; Beekman RH; Goldstein BH
    Congenit Heart Dis; 2014; 9(4):307-15. PubMed ID: 24102795
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?
    Imakiire N; Omae T; Matsunaga A; Sakata R; Kanmura Y
    J Anesth; 2010 Aug; 24(4):511-7. PubMed ID: 20490574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac output assessment methods in left ventricular assist device patients: A problem of heteroscedasticity.
    Azih NI; Read JM; Jackson GR; Inampudi C; Witer L; Kilic A; Pope NH; Hajj J; Haddad F; Tedford RJ; Houston BA
    J Heart Lung Transplant; 2023 Feb; 42(2):145-149. PubMed ID: 36481112
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements.
    Tehrani DM; Grinstein J; Kalantari S; Kim G; Sarswat N; Adatya S; Sayer G; Uriel N
    ASAIO J; 2017; 63(4):433-437. PubMed ID: 28125464
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of tricuspid regurgitation on thermodilution cardiac output: studies in an animal model.
    Kashtan HI; Maitland A; Salerno TA; Lichtenstein SV; Byrick RJ
    Can J Anaesth; 1987 May; 34(3 ( Pt 1)):246-51. PubMed ID: 3581394
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of thermodilution and Fick methods for measurement of cardiac output in tricuspid regurgitation.
    Konishi T; Nakamura Y; Morii I; Himura Y; Kumada T; Kawai C
    Am J Cardiol; 1992 Aug; 70(4):538-9. PubMed ID: 1642196
    [No Abstract]   [Full Text] [Related]  

  • 19. Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients.
    Gonzalez J; Delafosse C; Fartoukh M; Capderou A; Straus C; Zelter M; Derenne JP; Similowski T
    Crit Care; 2003 Apr; 7(2):171-8. PubMed ID: 12720564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prevalence and impact of preoperative moderate/severe tricuspid regurgitation on patients undergoing transcatheter aortic valve replacement.
    Barbanti M; Binder RK; Dvir D; Tan J; Freeman M; Thompson CR; Cheung A; Wood DA; Leipsic J; Webb JG
    Catheter Cardiovasc Interv; 2015 Mar; 85(4):677-84. PubMed ID: 24740834
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.