BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 36609847)

  • 1. Optimization of proton pencil beam positioning in collimated fields.
    Behrends C; Bäumer C; Verbeek NG; Wulff J; Timmermann B
    Med Phys; 2023 Apr; 50(4):2540-2551. PubMed ID: 36609847
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.
    Geoghegan TJ; Nelson NP; Flynn RT; Hill PM; Rana S; Hyer DE
    Med Phys; 2020 Jul; 47(7):2725-2734. PubMed ID: 32170750
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A study of lateral fall-off (penumbra) optimisation for pencil beam scanning (PBS) proton therapy.
    Winterhalter C; Lomax A; Oxley D; Weber DC; Safai S
    Phys Med Biol; 2018 Jan; 63(2):025022. PubMed ID: 29324441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Geoghegan TJ; Patwardhan KA; Smith BR; Flynn RT; Yu J; Rana S; Gutiérrez AN; Hill PM
    Med Phys; 2021 Jun; 48(6):3172-3185. PubMed ID: 33740253
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Smith BR; Flynn RT; Hill PM
    Biomed Phys Eng Express; 2022 Feb; 8(2):. PubMed ID: 35130520
    [No Abstract]   [Full Text] [Related]  

  • 6. Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy.
    Nabha R; De Saint-Hubert M; Marichal J; Esser J; Van Hoey O; Bäumer C; Verbeek N; Struelens L; Sterpin E; Tabury K; Marek L; Granja C; Timmermann B; Vanhavere F
    Phys Med Biol; 2023 Mar; 68(6):. PubMed ID: 36821866
    [No Abstract]   [Full Text] [Related]  

  • 7. Design and characterization of an aperture system and spot configuration for ocular treatments with a gantry-based spot scanning proton beam.
    Hickling SV; Corner S; Kruse JJ; Deisher AJ
    Med Phys; 2023 Jul; 50(7):4521-4532. PubMed ID: 37084072
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility.
    Ciocca M; Magro G; Mastella E; Mairani A; Mirandola A; Molinelli S; Russo S; Vai A; Fiore MR; Mosci C; Valvo F; Via R; Baroni G; Orecchia R
    Med Phys; 2019 Apr; 46(4):1852-1862. PubMed ID: 30659616
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy.
    Smith BR; Pankuch M; Hyer DE; Culberson WS
    Med Phys; 2020 Oct; 47(10):5343-5356. PubMed ID: 33411329
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning.
    Winterhalter C; Meier G; Oxley D; Weber DC; Lomax AJ; Safai S
    Phys Med Biol; 2018 Dec; 64(1):015002. PubMed ID: 30523928
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy.
    Smith BR; Nelson NP; Geoghegan TJ; Patwardhan KA; Hill PM; Yu J; Gutiérrez AN; Allen BG; Hyer DE
    Med Phys; 2022 Apr; 49(4):2684-2698. PubMed ID: 35120278
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of penumbra sharpening and scattering by adaptive aperture for a compact pencil beam scanning proton therapy system.
    Grewal HS; Ahmad S; Jin H
    Med Phys; 2021 Apr; 48(4):1508-1519. PubMed ID: 33580550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. PETRA: A pencil beam trimming algorithm for analytical proton therapy dose calculations with the dynamic collimation system.
    Bennett LC; Hyer DE; Erhart K; Nelson NP; Culberson WS; Smith BR; Hill PM; Flynn RT
    Med Phys; 2023 Nov; 50(11):7263-7280. PubMed ID: 37370239
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stereotactical fields applied in proton spot scanning mode with range shifter and collimating aperture.
    Bäumer C; Fuentes C; Janson M; Matic A; Timmermann B; Wulff J
    Phys Med Biol; 2019 Aug; 64(15):155003. PubMed ID: 31216523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.
    Safai S; Bortfeld T; Engelsman M
    Phys Med Biol; 2008 Mar; 53(6):1729-50. PubMed ID: 18367800
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of pencil beam scanning proton therapy with multi-leaf collimator calculated by a commercial Monte Carlo dose engine.
    Tominaga Y; Sakurai Y; Miyata J; Harada S; Akagi T; Oita M
    J Appl Clin Med Phys; 2022 Dec; 23(12):e13817. PubMed ID: 36420959
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Geoghegan TJ; Patwardhan KA; Smith BR; Flynn RT; Yu J; Gutiérrez AN; Hill PM
    Phys Med Biol; 2023 Feb; 68(5):. PubMed ID: 36706460
    [No Abstract]   [Full Text] [Related]  

  • 18. Implementation of apertures in a proton pencil-beam dose algorithm.
    Depauw N; Kooy HM; Daartz J; Bussière M; Batin E; Madden T; Williams M; Schueman J; Clasie BM
    Biomed Phys Eng Express; 2022 Feb; 8(2):. PubMed ID: 35158343
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fan-beam intensity modulated proton therapy.
    Hill P; Westerly D; Mackie T
    Med Phys; 2013 Nov; 40(11):111704. PubMed ID: 24320412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.
    Charlwood FC; Aitkenhead AH; Mackay RI
    Med Phys; 2016 Mar; 43(3):1462-72. PubMed ID: 26936730
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.