These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
169 related articles for article (PubMed ID: 36617620)
1. Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study. Dabli D; Loisy M; Frandon J; de Oliveira F; Meerun AM; Guiu B; Beregi JP; Greffier J Eur Radiol Exp; 2023 Jan; 7(1):1. PubMed ID: 36617620 [TBL] [Abstract][Full Text] [Related]
2. Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images. Greffier J; Viry A; Barbotteau Y; Frandon J; Loisy M; de Oliveira F; Beregi JP; Dabli D Med Phys; 2022 Apr; 49(4):2233-2244. PubMed ID: 35184293 [TBL] [Abstract][Full Text] [Related]
3. Spatial resolution, noise properties, and detectability index of a deep learning reconstruction algorithm for dual-energy CT of the abdomen. Thor D; Titternes R; Poludniowski G Med Phys; 2023 May; 50(5):2775-2786. PubMed ID: 36774193 [TBL] [Abstract][Full Text] [Related]
4. Technical performance of a dual-energy CT system with a novel deep-learning based reconstruction process: Evaluation using an abdomen protocol. Oostveen LJ; Boedeker KL; Balta C; Shin D; de Lange F; Prokop M; Sechopoulos I Med Phys; 2023 Mar; 50(3):1378-1389. PubMed ID: 36502496 [TBL] [Abstract][Full Text] [Related]
5. Comparison of virtual monoenergetic imaging between a rapid kilovoltage switching dual-energy computed tomography with deep-learning and four dual-energy CTs with iterative reconstruction. Greffier J; Si-Mohamed S; Guiu B; Frandon J; Loisy M; de Oliveira F; Douek P; Beregi JP; Dabli D Quant Imaging Med Surg; 2022 Feb; 12(2):1149-1162. PubMed ID: 35111612 [TBL] [Abstract][Full Text] [Related]
6. Comparison of two versions of a deep learning image reconstruction algorithm on CT image quality and dose reduction: A phantom study. Greffier J; Dabli D; Frandon J; Hamard A; Belaouni A; Akessoul P; Fuamba Y; Le Roy J; Guiu B; Beregi JP Med Phys; 2021 Oct; 48(10):5743-5755. PubMed ID: 34418110 [TBL] [Abstract][Full Text] [Related]
7. Impact of dose reduction and the use of an advanced model-based iterative reconstruction algorithm on spectral performance of a dual-source CT system: A task-based image quality assessment. Greffier J; Dabli D; Hamard A; Akessoul P; Belaouni A; Beregi JP; Frandon J Diagn Interv Imaging; 2021; 102(7-8):405-412. PubMed ID: 33820752 [TBL] [Abstract][Full Text] [Related]
8. Characteristics of the deep learning-based virtual monochromatic image with fast kilovolt-switching CT: a phantom study. Katsuyama Y; Kojima T; Shirasaka T; Kondo M; Kato T Radiol Phys Technol; 2023 Mar; 16(1):77-84. PubMed ID: 36583827 [TBL] [Abstract][Full Text] [Related]
9. Performance of four dual-energy CT platforms for abdominal imaging: a task-based image quality assessment based on phantom data. Greffier J; Si-Mohamed S; Dabli D; de Forges H; Hamard A; Douek P; Beregi JP; Frandon J Eur Radiol; 2021 Jul; 31(7):5324-5334. PubMed ID: 33449188 [TBL] [Abstract][Full Text] [Related]
10. Spectral performance of two split-filter dual-energy CT systems: A phantom study. Greffier J; Van Ngoc Ty C; Fitton I; Frandon J; Beregi JP; Dabli D Med Phys; 2023 Nov; 50(11):6828-6835. PubMed ID: 37672341 [TBL] [Abstract][Full Text] [Related]
11. Impact of an artificial intelligence deep-learning reconstruction algorithm for CT on image quality and potential dose reduction: A phantom study. Greffier J; Si-Mohamed S; Frandon J; Loisy M; de Oliveira F; Beregi JP; Dabli D Med Phys; 2022 Aug; 49(8):5052-5063. PubMed ID: 35696272 [TBL] [Abstract][Full Text] [Related]
12. Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study. Greffier J; Durand Q; Frandon J; Si-Mohamed S; Loisy M; de Oliveira F; Beregi JP; Dabli D Eur Radiol; 2023 Jan; 33(1):699-710. PubMed ID: 35864348 [TBL] [Abstract][Full Text] [Related]
13. Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical study. Fukutomi A; Sofue K; Ueshima E; Negi N; Ueno Y; Tsujita Y; Yabe S; Yamaguchi T; Shimada R; Kusaka A; Hori M; Murakami T Eur Radiol; 2023 Feb; 33(2):1388-1399. PubMed ID: 36114848 [TBL] [Abstract][Full Text] [Related]
14. Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study. Greffier J; Hamard A; Pereira F; Barrau C; Pasquier H; Beregi JP; Frandon J Eur Radiol; 2020 Jul; 30(7):3951-3959. PubMed ID: 32100091 [TBL] [Abstract][Full Text] [Related]
15. Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data. Greffier J; Frandon J; Si-Mohamed S; Dabli D; Hamard A; Belaouni A; Akessoul P; Besse F; Guiu B; Beregi JP Diagn Interv Imaging; 2022 Jan; 103(1):21-30. PubMed ID: 34493475 [TBL] [Abstract][Full Text] [Related]
16. Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study. Greffier J; Faby S; Pastor M; Frandon J; Erath J; Beregi JP; Dabli D Diagn Interv Imaging; 2024 Sep; 105(9):311-318. PubMed ID: 38429207 [TBL] [Abstract][Full Text] [Related]
17. Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Grant KL; Flohr TG; Krauss B; Sedlmair M; Thomas C; Schmidt B Invest Radiol; 2014 Sep; 49(9):586-92. PubMed ID: 24710203 [TBL] [Abstract][Full Text] [Related]
18. Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study. Greffier J; Faby S; Pastor M; Frandon J; Erath J; Beregi JP; Dabli D Phys Med; 2024 Aug; 124():103429. PubMed ID: 39024963 [TBL] [Abstract][Full Text] [Related]
19. Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data. Greffier J; Frandon J; Sadate A; Akessoul P; Belaouni A; Beregi JP; Dabli D J Appl Clin Med Phys; 2021 Aug; 22(8):243-254. PubMed ID: 34312979 [TBL] [Abstract][Full Text] [Related]
20. Comparison of two deep-learning image reconstruction algorithms on cardiac CT images: A phantom study. Greffier J; Pastor M; Si-Mohamed S; Goutain-Majorel C; Peudon-Balas A; Bensalah MZ; Frandon J; Beregi JP; Dabli D Diagn Interv Imaging; 2024 Mar; 105(3):110-117. PubMed ID: 37949769 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]