BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 3661958)

  • 1. [Clinical experiences with a new reusable pressure transducer].
    Brandt L; Dick W
    Anaesthesist; 1987 Aug; 36(8):450-4. PubMed ID: 3661958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An evaluation of the BD RT2000 reusable transducer system for invasive blood pressure monitoring.
    Ng KG; Chua TK; Tan C; Cole J; Quickel G
    Blood Press Monit; 2007 Feb; 12(1):35-43. PubMed ID: 17303986
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Zero stability of disposable and reusable pressure transducers.
    Gordon VL; Welch JP; Carley D; Teplick R; Newbower RS
    Med Instrum; 1987 Apr; 21(2):87-91. PubMed ID: 3614036
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Disposable transducers for invasive blood pressure measurement. A test of the dynamic characteristics].
    Nielsen LH
    Ugeskr Laeger; 1994 Aug; 156(31):4454-5. PubMed ID: 8066949
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Continuous registration of intracranial pressure using disposable transducers].
    Piek J; Krämer M; Bock WJ
    Anasth Intensivther Notfallmed; 1987 Feb; 22(1):30-2. PubMed ID: 3578720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparative study of unidirectional transducers for invasive blood pressure monitoring].
    Matzek F; Boenick U; Frucht U; Schroeder PM
    Biomed Tech (Berl); 1989 Mar; 34(3):34-41. PubMed ID: 2720045
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.
    Romagnoli S; Romano SM; Bevilacqua S; Lazzeri C; Gensini GF; Pratesi C; Quattrone D; Dini D; De Gaudio AR
    J Crit Care; 2011 Aug; 26(4):415-22. PubMed ID: 21036533
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous non-invasive blood pressure monitoring by brachial artery displacement method in high-risk surgical patients.
    Weiss BM; Spahn DR; Keller E; Seifert B; Pasch T
    Eur J Anaesthesiol; 1995 Nov; 12(6):555-63. PubMed ID: 8665877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mini-epidemic of erroneous central venous pressure measurements resulting from the malproduction of a specific part of a pressure transducer system.
    Görlinger K; Kehren CJ; Peters J
    Anesthesiology; 2009 Jun; 110(6):1417-8; discussion 1418-9. PubMed ID: 19417597
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extended use of disposable pressure transducers. A bacteriologic evaluation.
    Luskin RL; Weinstein RA; Nathan C; Chamberlin WH; Kabins SA
    JAMA; 1986 Feb; 255(7):916-20. PubMed ID: 3944997
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technology and application of ultraminiature catheter pressure transducers.
    Zimmer HG; Millar HD
    Can J Cardiol; 1998 Oct; 14(10):1259-66. PubMed ID: 9852939
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors.
    Gardner RM
    Crit Care Med; 1996 May; 24(5):879-82. PubMed ID: 8706469
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transducer hygiene -- an underrated topic?
    Merz E
    Ultraschall Med; 2005 Feb; 26(1):7-8. PubMed ID: 15700221
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Automatic non-invasive blood pressure determination--comparative determinations and experiences with the DINAMAP Vital Data 845 XT Monitor in the intensive care station].
    Hausmann D; Rommelsheim K
    Anasth Intensivther Notfallmed; 1983 Apr; 18(2):93-7. PubMed ID: 6869709
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Error in central venous pressure measurement.
    Figg KK; Nemergut EC
    Anesth Analg; 2009 Apr; 108(4):1209-11. PubMed ID: 19299788
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultraminiature strain gauge transducer for assessing regional intramyocardial pressure.
    Sabbah HN; Marzilli M; Stein PD
    Med Instrum; 1981; 15(2):121-4. PubMed ID: 7231242
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A continuous and non-invasive arterial pressure monitoring system in dialysis patients.
    Mambelli E; Mancini E; Santoro A
    Nephron Clin Pract; 2007; 107(4):c170-6. PubMed ID: 17975324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device.
    Maestri R; Pinna GD; Robbi E; Capomolla S; La Rovere MT
    Physiol Meas; 2005 Dec; 26(6):1125-36. PubMed ID: 16311459
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of possible measuring errors from overlaying pressure components in invasive blood pressure recording with external transducers].
    Lambertz M; Kraft M; Boenick U
    Biomed Tech (Berl); 1997 Sep; 42(9):249-55. PubMed ID: 9410155
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simple method to measure pulmonary artery pressure and central venous pressure with a single transducer.
    Pull ter Gunne AJ; Bruining HA
    Neth J Surg; 1984 Dec; 36(6):172-3. PubMed ID: 6521939
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 12.