These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 3661965)

  • 1. An evaluation of six disposable heat and moisture exchangers.
    Turtle MJ; Ilsley AH; Rutten AJ; Runciman WB
    Anaesth Intensive Care; 1987 Aug; 15(3):317-22. PubMed ID: 3661965
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.
    Martin C; Thomachot L; Quinio B; Viviand X; Albanese J
    Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of nine heat and moisture exchangers for intraoperative airway heat conservation.
    Tsubota K; Harada J; Goto Y
    J Aerosol Med; 1991; 4(2):117-25. PubMed ID: 10147688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours.
    Thomachot L; Vialet R; Viguier JM; Sidier B; Roulier P; Martin C
    Crit Care Med; 1998 Mar; 26(3):477-81. PubMed ID: 9504575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min.
    Martin C; Papazian L; Perrin G; Bantz P; Gouin F
    Chest; 1992 Nov; 102(5):1347-50. PubMed ID: 1424849
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The pall ultipor breathing circuit filter--an efficient heat and moisture exchanger.
    Chalon J; Markham JP; Ali MM; Ramanathan S; Turndorf H
    Anesth Analg; 1984 Jun; 63(6):566-70. PubMed ID: 6731877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
    Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
    Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360).
    Eckerbom B; Lindholm CE
    Acta Anaesthesiol Scand; 1990 Jul; 34(5):404-9. PubMed ID: 2389657
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The humidification of anesthetic gases during anesthesia using heat and moisture exchangers].
    Fritz KW; Osterhaus A; Mottner J
    Anaesthesiol Reanim; 1992; 17(3):133-44. PubMed ID: 1418281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The humidity in a Dräger Primus anesthesia workstation using low or high fresh gas flow and with or without a heat and moisture exchanger in pediatric patients.
    Bicalho GP; Braz LG; de Jesus LSB; Pedigone CMC; de Carvalho LR; Módolo NSP; Braz JRC
    Anesth Analg; 2014 Oct; 119(4):926-931. PubMed ID: 25010823
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of heat and moisture exchanger on humidity and body temperature in a low-flow anaesthesia system.
    Johansson A; Lundberg D; Luttropp HH
    Acta Anaesthesiol Scand; 2003 May; 47(5):564-8. PubMed ID: 12699514
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficiency of airway heat and moisture exchangers in anesthetized humans.
    Bickler PE; Sessler DI
    Anesth Analg; 1990 Oct; 71(4):415-8. PubMed ID: 2400121
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The temperature-humidity profile of the PhysioFlex. Studies on a model].
    Wissing H; Kuhn I; Kessler P
    Anaesthesist; 1997 Mar; 46(3):201-6. PubMed ID: 9163264
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
    Christiansen S; Renzing K; Hirche H; Reidemeister JC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study.
    Lucato JJ; Adams AB; Souza R; Torquato JA; Carvalho CR; Marini JJ
    Clinics (Sao Paulo); 2009; 64(6):585-90. PubMed ID: 19578664
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials.
    Braz JRC; Braz MG; Hayashi Y; Martins RHG; Betini M; Braz LG; El Dib R
    Eur J Anaesthesiol; 2017 Aug; 34(8):515-525. PubMed ID: 28403017
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new device for 100 per cent humidification of inspired air.
    Larsson A; Gustafsson A; Svanborg L
    Crit Care; 2000; 4(1):54-60. PubMed ID: 11056746
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.