These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 3662780)

  • 21. Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
    Hong JH; Mun MS
    Prosthet Orthot Int; 2005 Apr; 29(1):59-72. PubMed ID: 16180378
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.
    Courtney A; Orendurff MS; Buis A
    J Rehabil Med; 2016 Apr; 48(4):396-401. PubMed ID: 26983760
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects.
    Sanders JE; Jacobsen AK; Fergason JR
    Prosthet Orthot Int; 2006 Dec; 30(3):257-69. PubMed ID: 17162516
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.
    Chino N; Pearson JR; Cockrell JL; Mikishko HA; Koepke GH
    Arch Phys Med Rehabil; 1975 Jan; 56(1):22-6. PubMed ID: 1115589
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Modeling and simulation of muscle forces of trans-tibial amputee to study effect of prosthetic alignment.
    Fang L; Jia X; Wang R
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1125-31. PubMed ID: 17942203
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Total surface bearing self suspending above-knee sockets.
    Redhead RG
    Prosthet Orthot Int; 1979 Dec; 3(3):126-36. PubMed ID: 523290
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.
    Al-Fakih E; Arifin N; Pirouzi G; Mahamd Adikan FR; Shasmin HN; Abu Osman NA
    J Biomed Opt; 2017 Aug; 22(8):1-8. PubMed ID: 28822140
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Interface load analysis for computer-aided design of below-knee prosthetic sockets.
    Reynolds DP; Lord M
    Med Biol Eng Comput; 1992 Jul; 30(4):419-26. PubMed ID: 1487943
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Hanging stump prosthesis without socket for bad above-knee stumps.
    Chand N; Srivastava RK; Maish AR
    Prosthet Orthot Int; 1985 Dec; 9(3):154-6. PubMed ID: 4088844
    [TBL] [Abstract][Full Text] [Related]  

  • 30. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review.
    Mak AF; Zhang M; Boone DA
    J Rehabil Res Dev; 2001; 38(2):161-74. PubMed ID: 11392649
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless.
    Kahle JT; Highsmith MJ
    J Rehabil Res Dev; 2013; 50(9):1241-52. PubMed ID: 24458964
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quantitative analysis of interface pressures in transfemoral prosthetic sockets.
    PaternĂ² L; Truppa L; Ibrahimi M; Rosini E; Gruppioni E; Ricotti L; Menciassi A
    Prosthet Orthot Int; 2024 Apr; 48(2):176-183. PubMed ID: 37379468
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The AirCirc: design and development of a thermal management prototype device for below-knee prosthesis leg socket.
    Nurhanisah MH; Jawaid M; Ahmad Azmeer R; Paridah MT
    Disabil Rehabil Assist Technol; 2019 Jul; 14(5):513-520. PubMed ID: 29933703
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Dynamic loads at knee joint of trans-tibial amputee on different terrains].
    Jia X; Zhang M; Fan Y; Wang R
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Apr; 22(2):221-4. PubMed ID: 15884522
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Swing phase control with knee friction in juvenile amputees.
    Hicks R; Tashman S; Cary JM; Altman RF; Gage JR
    J Orthop Res; 1985; 3(2):198-201. PubMed ID: 3998896
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites.
    Sanders JE; Bell DM; Okumura RM; Dralle AJ
    IEEE Trans Rehabil Eng; 1998 Mar; 6(1):21-31. PubMed ID: 9535520
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A study of interface pressures in the below-knee prosthesis (physiological suspension: an interim report).
    Burgess EM; Moore AJ
    Bull Prosthet Res; 1977; ():58-70. PubMed ID: 615653
    [No Abstract]   [Full Text] [Related]  

  • 38. Gait, cost and time implications for changing from PTB to ICEX sockets.
    Datta D; Harris I; Heller B; Howitt J; Martin R
    Prosthet Orthot Int; 2004 Aug; 28(2):115-20. PubMed ID: 15382805
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Characterization of interfacial socket pressure in transhumeral prostheses: A case series.
    Schofield JS; Schoepp KR; Williams HE; Carey JP; Marasco PD; Hebert JS
    PLoS One; 2017; 12(6):e0178517. PubMed ID: 28575012
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.
    Sanders JE; Daly CH
    J Rehabil Res Dev; 1993; 30(2):191-204. PubMed ID: 8035348
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.