167 related articles for article (PubMed ID: 36628756)
1. Rapid simultaneous SERS detection of dual myocardial biomarkers on single-track finger-pump microfluidic chip.
Liu Y; Gao R; Zhuo Y; Wang Y; Jia H; Chen X; Lu Y; Zhang D; Yu L
Anal Chim Acta; 2023 Jan; 1239():340673. PubMed ID: 36628756
[TBL] [Abstract][Full Text] [Related]
2. SERS-based immunoassay using gold-patterned array chips for rapid and sensitive detection of dual cardiac biomarkers.
Cheng Z; Wang R; Xing Y; Zhao L; Choo J; Yu F
Analyst; 2019 Nov; 144(22):6533-6540. PubMed ID: 31553332
[TBL] [Abstract][Full Text] [Related]
3. SERS-Based Immunoassay of Myocardial Infarction Biomarkers on a Microfluidic Chip with Plasmonic Nanostripe Microcones.
Gao R; Mao Y; Ma C; Wang Y; Jia H; Chen X; Lu Y; Zhang D; Yu L
ACS Appl Mater Interfaces; 2022 Dec; 14(50):55414-55422. PubMed ID: 36480247
[TBL] [Abstract][Full Text] [Related]
4. Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers.
Lim WY; Goh CH; Thevarajah TM; Goh BT; Khor SM
Biosens Bioelectron; 2020 Jan; 147():111792. PubMed ID: 31678828
[TBL] [Abstract][Full Text] [Related]
5. One-Stop Plasmonic Nanocube-Excited SERS Immunoassay Platform of Multiple Cardiac Biomarkers for Rapid Screening and Progressive Tracing of Acute Myocardial Infarction.
Lee H; Kim W; Song MY; Kim DH; Jung HS; Kim W; Choi S
Small; 2024 Feb; 20(8):e2304999. PubMed ID: 37821412
[TBL] [Abstract][Full Text] [Related]
6. A capillary-based microfluidic chip with the merits of low cost and easy fabrication for the rapid detection of acute myocardial infarction.
Li X; Xu C; Chen H; Yi F; Liao J; Han J; Li C; Han W; Han RPS; Chen H
Talanta; 2023 Dec; 265():124924. PubMed ID: 37437393
[TBL] [Abstract][Full Text] [Related]
7. Paper microfluidic device for early diagnosis and prognosis of acute myocardial infarction via quantitative multiplex cardiac biomarker detection.
Lim WY; Thevarajah TM; Goh BT; Khor SM
Biosens Bioelectron; 2019 Mar; 128():176-185. PubMed ID: 30685097
[TBL] [Abstract][Full Text] [Related]
8. Digital Microfluidic Thermal Control Chip-Based Multichannel Immunosensor for Noninvasively Detecting Acute Myocardial Infarction.
Shen J; Zhang L; Yuan J; Zhu Y; Cheng H; Zeng Y; Wang J; You X; Yang C; Qu X; Chen H
Anal Chem; 2021 Nov; 93(45):15033-15041. PubMed ID: 34730944
[TBL] [Abstract][Full Text] [Related]
9. Rapid diagnosis of acute myocardial infarction through integrated microfluidic chips for detection of characteristic targets.
Yuan Y; Zhong Y; Yang Y; Li K
Anal Biochem; 2024 Jun; 689():115502. PubMed ID: 38453047
[TBL] [Abstract][Full Text] [Related]
10. Clinical Value of Combined Detection of CK-MB, MYO, cTnI and Plasma NT-proBNP in Diagnosis of Acute Myocardial Infarction.
Fan J; Ma J; Xia N; Sun L; Li B; Liu H
Clin Lab; 2017 Mar; 63(3):427-433. PubMed ID: 28271683
[TBL] [Abstract][Full Text] [Related]
11. Quantitative measurement of acute myocardial infarction cardiac biomarkers by "All-in-One" immune microfluidic chip for early diagnosis of myocardial infarction.
Zeng Z; Li H; Li Q; Sun R; Zhang X; Zhang D; Zhu Q; Chen C
Spectrochim Acta A Mol Biomol Spectrosc; 2024 Jul; 315():124256. PubMed ID: 38615418
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a point-of-care assay for cardiac markers for patients suspected of acute myocardial infarction.
Wu AH; Smith A; Christenson RH; Murakami MM; Apple FS
Clin Chim Acta; 2004 Aug; 346(2):211-9. PubMed ID: 15256323
[TBL] [Abstract][Full Text] [Related]
13. [Evaluation on usage of serum troponin-I, CK-MBmass and myoglobin measurements in diagnosing acute myocardial infarction].
Wang L; Wu Y; Li L
Hua Xi Yi Ke Da Xue Xue Bao; 2000 Jun; 31(2):239-41, 245. PubMed ID: 12515148
[TBL] [Abstract][Full Text] [Related]
14. Delta CK-MB outperforms delta troponin I at 2 hours during the ED rule out of acute myocardial infarction.
Fesmire FM
Am J Emerg Med; 2000 Jan; 18(1):1-8. PubMed ID: 10674522
[TBL] [Abstract][Full Text] [Related]
15. Randomised Assessment of Treatment using Panel Assay of Cardiac markers--Contemporary Biomarker Evaluation (RATPAC CBE).
Collinson PO; Gaze DC; Thokala P; Goodacre S
Health Technol Assess; 2013; 17(15):v-vi, 1-122. PubMed ID: 23597479
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of Myocardial Biomarkers in the Diagnosis of Myocardial Infarction After Revascularization as Assessed by Cardiac Resonance: The Medicine, Angioplasty, Surgery Study V (MASS-V) Trial.
Hueb W; Gersh BJ; Alves da Costa LM; Costa Oikawa FT; Vieira de Melo RM; Rezende PC; Garzillo CL; Lima EG; Nomura CH; Villa AV; Hueb AC; Cassaro Strunz CM; Favarato D; Takiuti ME; de Albuquerque CP; Ribeiro da Silva EE; Franchini Ramires JA; Kalil Filho R
Ann Thorac Surg; 2016 Jun; 101(6):2202-8. PubMed ID: 26912303
[TBL] [Abstract][Full Text] [Related]
17. [Quantitative analysis of serum troponin I and myoglobin in patients with acute myocardial infarction].
Xiao HG; Huang ZH; Liu HX; Lin YP
Di Yi Jun Yi Da Xue Xue Bao; 2005 May; 25(5):550-1. PubMed ID: 15897132
[TBL] [Abstract][Full Text] [Related]
18. SERS-based competitive immunoassay of troponin I and CK-MB markers for early diagnosis of acute myocardial infarction.
Chon H; Lee S; Yoon SY; Lee EK; Chang SI; Choo J
Chem Commun (Camb); 2014 Feb; 50(9):1058-60. PubMed ID: 24310060
[TBL] [Abstract][Full Text] [Related]
19. SERS-Based Pump-Free Microfluidic Chip for Highly Sensitive Immunoassay of Prostate-Specific Antigen Biomarkers.
Gao R; Lv Z; Mao Y; Yu L; Bi X; Xu S; Cui J; Wu Y
ACS Sens; 2019 Apr; 4(4):938-943. PubMed ID: 30864786
[TBL] [Abstract][Full Text] [Related]
20. Serum markers in the emergency department diagnosis of acute myocardial infarction.
Karras DJ; Kane DL
Emerg Med Clin North Am; 2001 May; 19(2):321-37. PubMed ID: 11373981
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]