These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 36636623)

  • 1. Impact of a Swept Source-Optical Coherence Tomography Device on Efficiency in Cataract Evaluation and Surgery: A Time-and-Motion Study.
    Multack S; Pan LC; Timmons SK; Datar M; Hsiao CW; Babu R; Pan SM; Woodard L
    Clin Ophthalmol; 2023; 17():1-13. PubMed ID: 36636623
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biometry measurements using a new large-coherence-length swept-source optical coherence tomographer.
    Shammas HJ; Ortiz S; Shammas MC; Kim SH; Chong C
    J Cataract Refract Surg; 2016 Jan; 42(1):50-61. PubMed ID: 26948778
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study.
    An Y; Kang EK; Kim H; Kang MJ; Byun YS; Joo CK
    BMC Ophthalmol; 2019 Jan; 19(1):30. PubMed ID: 30678658
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative Analysis of Swept-Source Optical Coherence Tomography and Partial Coherence Interferometry Biometers in the Prediction of Cataract Surgery Refractive Outcomes.
    Cummings AB; Naughton S; Coen AM; Brennan E; Kelly GE
    Clin Ophthalmol; 2020; 14():4209-4220. PubMed ID: 33293790
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comprehensive Comparison of Axial Length Measurement With Three Swept-Source OCT-Based Biometers and Partial Coherence Interferometry.
    Huang J; Chen H; Li Y; Chen Z; Gao R; Yu J; Zhao Y; Lu W; McAlinden C; Wang Q
    J Refract Surg; 2019 Feb; 35(2):115-120. PubMed ID: 30742226
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer.
    Fişuş AD; Hirnschall ND; Ruiss M; Pilwachs C; Georgiev S; Findl O
    J Cataract Refract Surg; 2021 Oct; 47(10):1302-1307. PubMed ID: 33770018
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry.
    Hoffer KJ; Hoffmann PC; Savini G
    J Cataract Refract Surg; 2016 Aug; 42(8):1165-72. PubMed ID: 27531293
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device.
    Kurian M; Negalur N; Das S; Puttaiah NK; Haria D; J TS; Thakkar MM
    J Cataract Refract Surg; 2016 Apr; 42(4):577-81. PubMed ID: 27113881
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry.
    Kunert KS; Peter M; Blum M; Haigis W; Sekundo W; Schütze J; Büehren T
    J Cataract Refract Surg; 2016 Jan; 42(1):76-83. PubMed ID: 26948781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer.
    Yang CM; Lim DH; Kim HJ; Chung TY
    PLoS One; 2019; 14(10):e0223114. PubMed ID: 31603903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical failure rates for biometry between swept-source and older-generation optical coherence methods: a review and meta-analysis.
    Kanclerz P; Hecht I; Tuuminen R
    BMC Ophthalmol; 2023 Apr; 23(1):182. PubMed ID: 37101115
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract.
    Tamaoki A; Kojima T; Hasegawa A; Yamamoto M; Kaga T; Tanaka K; Ichikawa K
    Ophthalmic Res; 2021; 64(4):595-603. PubMed ID: 33550307
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of SS-OCT biometry compared with partial coherence interferometry biometry for combined phacovitrectomy with internal limiting membrane peeling.
    Vounotrypidis E; Haralanova V; Muth DR; Wertheimer C; Shajari M; Wolf A; Priglinger S; Mayer WJ
    J Cataract Refract Surg; 2019 Jan; 45(1):48-53. PubMed ID: 30309772
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.
    Grulkowski I; Liu JJ; Zhang JY; Potsaid B; Jayaraman V; Cable AE; Duker JS; Fujimoto JG
    Ophthalmology; 2013 Nov; 120(11):2184-90. PubMed ID: 23755873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer.
    Srivannaboon S; Chirapapaisan C; Chonpimai P; Loket S
    J Cataract Refract Surg; 2015 Oct; 41(10):2224-32. PubMed ID: 26703299
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Axial length measurements: Comparison of a new swept-source optical coherence tomography-based biometer and partial coherence interferometry in myopia.
    Yang JY; Kim HK; Kim SS
    J Cataract Refract Surg; 2017 Mar; 43(3):328-332. PubMed ID: 28410713
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of a new swept-source optical biometer with a partial coherence interferometry.
    Lee HK; Kim MK
    BMC Ophthalmol; 2018 Oct; 18(1):269. PubMed ID: 30340561
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparision of two new optical biometry devices with an ultrasonic immersion biometer].
    Chiseliţă D; Cantemir A; Gălăţanu C; Irod A
    Oftalmologia; 2011; 55(4):104-10. PubMed ID: 22642145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical Evaluation of a New Swept-Source Optical Coherence Biometer That Uses Individual Refractive Indices to Measure Axial Length in Cataract Patients.
    Tamaoki A; Kojima T; Hasegawa A; Yamamoto M; Kaga T; Tanaka K; Ichikawa K
    Ophthalmic Res; 2019; 62(1):11-23. PubMed ID: 30889604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients.
    Chirapapaisan C; Srivannaboon S; Chonpimai P
    Optom Vis Sci; 2020 Mar; 97(3):186-191. PubMed ID: 32168241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.