These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 36637876)

  • 1. Highly Integrated μGC Based on a Multisensing Progressive Cellular Architecture with a Valveless Sample Inlet.
    Liao W; Winship D; Lara-Ibeas I; Zhao X; Xu Q; Lu HT; Qian T; Gordenker R; Qin Y; Gianchandani YB
    Anal Chem; 2023 Jan; 95(4):2157-2167. PubMed ID: 36637876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Progressive Cellular Architecture in Microscale Gas Chromatography for Broad Chemical Analyses.
    Liao W; Zhao X; Lu HT; Byambadorj T; Qin Y; Gianchandani YB
    Sensors (Basel); 2021 Apr; 21(9):. PubMed ID: 33946637
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control Software Design for a Multisensing Multicellular Microscale Gas Chromatography System.
    Xu Q; Zhao X; Qin Y; Gianchandani YB
    Micromachines (Basel); 2023 Dec; 15(1):. PubMed ID: 38258214
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of thermal desorption kinetics on vapor injection peak irregularities by a microscale gas chromatography preconcentrator.
    Seo JH; Liu J; Fan X; Kurabayashi K
    Anal Chem; 2012 Aug; 84(15):6336-40. PubMed ID: 22780835
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A purge and trap integrated microGC platform for chemical identification in aqueous samples.
    Akbar M; Narayanan S; Restaino M; Agah M
    Analyst; 2014 Jul; 139(13):3384-92. PubMed ID: 24837988
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fully electronic microfabricated gas chromatograph with complementary capacitive detectors for indoor pollutants.
    Qin Y; Gianchandani YB
    Microsyst Nanoeng; 2016; 2():15049. PubMed ID: 31057813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Selective Detection of Volatile Organics in a Mixture Using a Photoionization Detector and Thermal Desorption from a Nanoporous Preconcentrator.
    Prestage J; Day C; Husheer SLG; Winter WT; Ho WO; Saffell JR; Hutter T
    ACS Sens; 2022 Jan; 7(1):304-311. PubMed ID: 34958564
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A monolithically-integrated μGC chemical sensor system.
    Manginell RP; Bauer JM; Moorman MW; Sanchez LJ; Anderson JM; Whiting JJ; Porter DA; Copic D; Achyuthan KE
    Sensors (Basel); 2011; 11(7):6517-32. PubMed ID: 22163970
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance characteristics of a new prototype for a portable GC using ambient air as carrier gas for on-site analysis.
    Sanchez JM; Sacks RD
    J Sep Sci; 2007 May; 30(7):1052-60. PubMed ID: 17566340
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.
    Liu J; Seo JH; Li Y; Chen D; Kurabayashi K; Fan X
    Lab Chip; 2013 Mar; 13(5):818-25. PubMed ID: 23303462
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multidimensional micro gas chromatograph employing a parallel separation multi-column chip and stop-flow μGC × μGCs configuration.
    Chen BX; Hung TY; Jian RS; Lu CJ
    Lab Chip; 2013 Apr; 13(7):1333-41. PubMed ID: 23381092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measuring real-time concentration trends of individual VOC in an elementary school using a sub-ppb detection μGC and a single GC-MS analysis.
    Jian RS; Sung LY; Lu CJ
    Chemosphere; 2014 Mar; 99():261-6. PubMed ID: 24314896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A carbon nanotube sponge as an adsorbent for vapor preconcentration of aromatic volatile organic compounds.
    Bang J; You DW; Jang Y; Oh JS; Jung KW
    J Chromatogr A; 2019 Nov; 1605():460363. PubMed ID: 31320133
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Toward a microfabricated preconcentrator-focuser for a wearable micro-scale gas chromatograph.
    Bryant-Genevier J; Zellers ET
    J Chromatogr A; 2015 Nov; 1422():299-309. PubMed ID: 26530144
    [TBL] [Abstract][Full Text] [Related]  

  • 15. GC-on-chip: integrated column and photoionization detector.
    Akbar M; Shakeel H; Agah M
    Lab Chip; 2015 Apr; 15(7):1748-58. PubMed ID: 25673367
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-Sensitivity Micro-Gas Chromatograph-Photoionization Detector for Trace Vapor Detection.
    Wei-Hao Li M; Ghosh A; Venkatasubramanian A; Sharma R; Huang X; Fan X
    ACS Sens; 2021 Jun; 6(6):2348-2355. PubMed ID: 34028248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Compact, Automated, Inexpensive, and Field-Deployable Vacuum-Outlet Gas Chromatograph for Trace-Concentration Gas-Phase Organic Compounds.
    Skog KM; Xiong F; Kawashima H; Doyle E; Soto R; Gentner DR
    Anal Chem; 2019 Jan; 91(2):1318-1327. PubMed ID: 30605307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity.
    Soo JC; Lee EG; LeBouf RF; Kashon ML; Chisholm W; Harper M
    J Occup Environ Hyg; 2018 Apr; 15(4):351-360. PubMed ID: 29333991
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microfabricated gas chromatograph for on-site determination of trichloroethylene in indoor air arising from vapor intrusion. 1. Field evaluation.
    Kim SK; Burris DR; Chang H; Bryant-Genevier J; Zellers ET
    Environ Sci Technol; 2012 Jun; 46(11):6065-72. PubMed ID: 22616709
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A portable gas chromatograph for real-time monitoring of aromatic volatile organic compounds in air samples.
    You DW; Seon YS; Jang Y; Bang J; Oh JS; Jung KW
    J Chromatogr A; 2020 Aug; 1625():461267. PubMed ID: 32709320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.