These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
116 related articles for article (PubMed ID: 3663813)
1. [Mass spectrometry analysis system for measuring blood gas partial pressure in syringe samples]. Meyer BU; Züchner K; Hellige G Biomed Tech (Berl); 1987; 32(7-8):171-6. PubMed ID: 3663813 [No Abstract] [Full Text] [Related]
2. Effects of syringe type and storage temperature on results of blood gas analysis in arterial blood of horses. Picandet V; Jeanneret S; Lavoie JP J Vet Intern Med; 2007; 21(3):476-81. PubMed ID: 17552454 [TBL] [Abstract][Full Text] [Related]
3. Effects of syringe material and needle size on the minimum plunger-displacement pressure of arterial blood gas syringes. Ansel GM; Douce FH Respir Care; 1982 Feb; 27(2):147-51. PubMed ID: 10315159 [TBL] [Abstract][Full Text] [Related]
4. Blood gas techniques. MacLaren RE Respir Med; 1993 Jan; 87(1):79-80. PubMed ID: 8438106 [No Abstract] [Full Text] [Related]
5. Evaluating arterial blood gas syringes. Munz N Am J Nurs; 1993 Oct; 93(10):68. PubMed ID: 8213949 [No Abstract] [Full Text] [Related]
6. Arterial blood gas syringe safety device: does it present a greater hazard? Jain S; Weinbren M; Rowley J; Bradley A J Hosp Infect; 2004 Jul; 57(3):264-5. PubMed ID: 15236858 [No Abstract] [Full Text] [Related]
7. Utilization of Pharma-Plast syringes for gas level determination. Andreasen EE; Bøgh A Acta Anaesthesiol Scand; 1980 Oct; 24(5):399-401. PubMed ID: 7468130 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of arterial blood sampling using the B 109 syringe (radiometer). Fassoulaki A; Athanassiou E Acta Anaesthesiol Belg; 1986; 37(4):271-3. PubMed ID: 3105223 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of lyophilized heparin syringes for the collection of arterial blood for acid base analysis. Crockett AJ; McIntyre E; Ruffin R; Alpers JH Anaesth Intensive Care; 1981 Feb; 9(1):40-2. PubMed ID: 7258598 [TBL] [Abstract][Full Text] [Related]
11. Arterial blood sampling in neonates. Smith AD Lancet; 1975 Feb; 1(7901):254-5. PubMed ID: 46392 [No Abstract] [Full Text] [Related]
12. Arterial blood gas sampling: using a safety and pre-heparinised syringe. Hill S; Moore S Br J Nurs; 2018 Jul; 27(14):S20-S26. PubMed ID: 30048173 [TBL] [Abstract][Full Text] [Related]
13. The comparison of heparinized insulin syringes and safety-engineered blood gas syringes used in arterial blood gas sampling in the ED setting (randomized controlled study). Baskın SB; Oray NÇ; Yanturalı S; Bayram B Am J Emerg Med; 2014 May; 32(5):432-7. PubMed ID: 24560392 [TBL] [Abstract][Full Text] [Related]
14. Arterial blood gas sampling using a modified standard plastic syringe. Campbell JH; Carter R; Milroy R; Campbell LA; Banham SW Br J Clin Pract; 1990 Mar; 44(3):96-7. PubMed ID: 2111713 [TBL] [Abstract][Full Text] [Related]
15. Validation of a new arterial micro sampling device. Cohill JD; White FK Respir Care; 1982 Oct; 27(10):1210-4. PubMed ID: 10315312 [TBL] [Abstract][Full Text] [Related]
16. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test. Smeenk FW; Janssen JD; Arends BJ; Harff GA; van den Bosch JA; Schönberger JP; Postmus PE Eur Respir J; 1997 Apr; 10(4):910-3. PubMed ID: 9150334 [TBL] [Abstract][Full Text] [Related]
17. Use of evacuated collection tubes for routine determination of arterial blood gases and pH. Fleisher M; Schwartz MK Clin Chem; 1971 Jul; 17(7):610-3. PubMed ID: 5556888 [No Abstract] [Full Text] [Related]
18. Sending blood gas specimens through pressurized transport tube systems exaggerates the error in oxygen tension measurements created by the presence of air bubbles. McKane MH; Southorn PA; Santrach PJ; Burritt MF; Plevak DJ Anesth Analg; 1995 Jul; 81(1):179-82. PubMed ID: 7598253 [No Abstract] [Full Text] [Related]
19. Evaluation of the sampling technique and storage of blood using the B 109 Arterial Blood Sampler syringe. Thomsen A; Andersen LH Scand J Clin Lab Invest; 1976 Dec; 36(8):857-9. PubMed ID: 1031497 [TBL] [Abstract][Full Text] [Related]
20. [Aerobic blood sampling technique using the B 109-syringe (author's transl)]. Andersen LH; Thomsen A Anaesthesist; 1978 Mar; 27(3):143-4. PubMed ID: 25595 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]