These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 36638814)

  • 1. Finding the Lost Dissociation Constant of Electrochemical Aptamer-Based Biosensors.
    Rahbarimehr E; Chao HP; Churcher ZR; Slavkovic S; Kaiyum YA; Johnson PE; Dauphin-Ducharme P
    Anal Chem; 2023 Jan; 95(4):2229-2237. PubMed ID: 36638814
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Subsecond-Resolved Molecular Measurements in the Living Body Using Chronoamperometrically Interrogated Aptamer-Based Sensors.
    Arroyo-Currás N; Dauphin-Ducharme P; Ortega G; Ploense KL; Kippin TE; Plaxco KW
    ACS Sens; 2018 Feb; 3(2):360-366. PubMed ID: 29124939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Redox Reporter - Ligand Competition to Support Signaling in the Cocaine-Binding Electrochemical Aptamer-Based Biosensor.
    Dauphin-Ducharme P; Churcher ZR; Shoara AA; Rahbarimehr E; Slavkovic S; Fontaine N; Boisvert O; Johnson PE
    Chemistry; 2023 Jun; 29(35):e202300618. PubMed ID: 36988081
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microscale, Electrochemical, Aptamer-Based Sensors for Enhanced Small-Molecule Detection at Millisecond Time Scales.
    Kumakli H; Baldwin M; Abeykoon SW; White RJ
    ACS Sens; 2023 Dec; 8(12):4521-4530. PubMed ID: 38104257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interrogation of Electrochemical Aptamer-Based Sensors via Peak-to-Peak Separation in Cyclic Voltammetry Improves the Temporal Stability and Batch-to-Batch Variability in Biological Fluids.
    Pellitero MA; Curtis SD; Arroyo-Currás N
    ACS Sens; 2021 Mar; 6(3):1199-1207. PubMed ID: 33599479
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration-Free, Seconds-Resolved In Vivo Molecular Measurements using Fourier-Transform Impedance Spectroscopy Interrogation of Electrochemical Aptamer Sensors.
    Roehrich B; Leung KK; Gerson J; Kippin TE; Plaxco KW; Sepunaru L
    ACS Sens; 2023 Aug; 8(8):3051-3059. PubMed ID: 37584531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An electrochemical aptamer-based sensor prepared by utilizing the strong interaction between a DNA aptamer and diamond.
    Asai K; Yamamoto T; Nagashima S; Ogata G; Hibino H; Einaga Y
    Analyst; 2020 Jan; 145(2):544-549. PubMed ID: 31764923
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements.
    Wang Y; Duan H; Yalikun Y; Cheng S; Li M
    Anal Chim Acta; 2024 May; 1305():342587. PubMed ID: 38677841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Subsecond-Resolved Molecular Measurements Using Electrochemical Phase Interrogation of Aptamer-Based Sensors.
    Downs AM; Gerson J; Ploense KL; Plaxco KW; Dauphin-Ducharme P
    Anal Chem; 2020 Oct; 92(20):14063-14068. PubMed ID: 32959647
    [TBL] [Abstract][Full Text] [Related]  

  • 10. DNA aptamers selection and characterization for development of label-free impedimetric aptasensor for neurotoxin anatoxin-a.
    Elshafey R; Siaj M; Zourob M
    Biosens Bioelectron; 2015 Jun; 68():295-302. PubMed ID: 25594161
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Re-engineering aptamers to support reagentless, self-reporting electrochemical sensors.
    White RJ; Rowe AA; Plaxco KW
    Analyst; 2010 Mar; 135(3):589-94. PubMed ID: 20174715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrochemical current rectification-a novel signal amplification strategy for highly sensitive and selective aptamer-based biosensor.
    Feng L; Sivanesan A; Lyu Z; Offenhäusser A; Mayer D
    Biosens Bioelectron; 2015 Apr; 66():62-8. PubMed ID: 25460883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual-Frequency, Ratiometric Approaches to EAB Sensor Interrogation Support the Calibration-Free Measurement of Specific Molecules In Vivo.
    Verrinder E; Gerson J; Leung K; Kippin TE; Plaxco KW
    ACS Sens; 2024 Jun; 9(6):3205-3211. PubMed ID: 38775190
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Selection and Characterization of DNA Aptamers for Electrochemical Biosensing of Carbendazim.
    Eissa S; Zourob M
    Anal Chem; 2017 Mar; 89(5):3138-3145. PubMed ID: 28264568
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Construction and application of an electrochemical biosensor based on an endotoxin aptamer.
    Ying G; Wang M; Yi Y; Chen J; Mei J; Zhang Y; Chen S
    Biotechnol Appl Biochem; 2018 May; 65(3):323-327. PubMed ID: 28887814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Alkanethiol Monolayer End Groups Affect the Long-Term Operational Stability and Signaling of Electrochemical, Aptamer-Based Sensors in Biological Fluids.
    Shaver A; Curtis SD; Arroyo-Currás N
    ACS Appl Mater Interfaces; 2020 Mar; 12(9):11214-11223. PubMed ID: 32040915
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of Alpha-Fetoprotein Using Aptamer-Based Sensors.
    Liu L; Wang H; Xie B; Zhang B; Lin Y; Gao L
    Biosensors (Basel); 2022 Sep; 12(10):. PubMed ID: 36290918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemical selection of a DNA aptamer, and an impedimetric method for determination of the dedicator of cytokinesis 8 by self-assembly of a thiolated aptamer on a gold electrode.
    Eissa S; Siddiqua A; Chinnappan R; Zourob M
    Mikrochim Acta; 2019 Nov; 186(12):828. PubMed ID: 31754797
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid Two-Millisecond Interrogation of Electrochemical, Aptamer-Based Sensor Response Using Intermittent Pulse Amperometry.
    Santos-Cancel M; Lazenby RA; White RJ
    ACS Sens; 2018 Jun; 3(6):1203-1209. PubMed ID: 29762016
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical determination of zearalenone using a label-free competitive aptasensor.
    Azri FA; Eissa S; Zourob M; Chinnappan R; Sukor R; Yusof NA; Raston NHA; Alhoshani A; Jinap S
    Mikrochim Acta; 2020 Apr; 187(5):266. PubMed ID: 32279134
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.