201 related articles for article (PubMed ID: 36639787)
21. Arterial to end-tidal carbon dioxide pressure difference during laparoscopic surgery in pregnancy.
Bhavani-Shankar K; Steinbrook RA; Brooks DC; Datta S
Anesthesiology; 2000 Aug; 93(2):370-3. PubMed ID: 10910483
[TBL] [Abstract][Full Text] [Related]
22. Accuracy of Transcutaneous Carbon Dioxide Levels in Comparison to Arterial Carbon Dioxide Levels in Critically Ill Children.
Bhalla AK; Khemani RG; Hotz JC; Morzov RP; Newth CJ
Respir Care; 2019 Feb; 64(2):201-208. PubMed ID: 30254042
[TBL] [Abstract][Full Text] [Related]
23. Monitoring of the ventilatory status of anesthetized birds of prey by using end-tidal carbon dioxide measured with a microstream capnometer.
Desmarchelier M; Rondenay Y; Fitzgerald G; Lair S
J Zoo Wildl Med; 2007 Mar; 38(1):1-6. PubMed ID: 17469268
[TBL] [Abstract][Full Text] [Related]
24. Transcutaneous continuous carbon dioxide tension monitoring reduced incidence, degree and duration of hypercapnia during combined regional anaesthesia and monitored anaesthesia care in shoulder surgery patients.
Baulig W; Keselj M; Baulig B; Guzzella S; Borgeat A; Aguirre J
J Clin Monit Comput; 2015 Aug; 29(4):499-507. PubMed ID: 25312782
[TBL] [Abstract][Full Text] [Related]
25. Comparison of End-Tidal, Arterial, Venous, and Transcutaneous P
Fujimoto S; Suzuki M; Sakamoto K; Ibusuki R; Tamura K; Shiozawa A; Ishii S; Iikura M; Izumi S; Sugiyama H
Respir Care; 2019 Oct; 64(10):1208-1214. PubMed ID: 31337742
[TBL] [Abstract][Full Text] [Related]
26. A comparison of transcutaneous end-tidal and arterial measurements of carbon dioxide during general anaesthesia.
Reid CW; Martineau RJ; Miller DR; Hull KA; Baines J; Sullivan PJ
Can J Anaesth; 1992 Jan; 39(1):31-6. PubMed ID: 1733530
[TBL] [Abstract][Full Text] [Related]
27. Sleep Transcutaneous vs. End-Tidal CO2 Monitoring for Patients with Neuromuscular Disease.
Won YH; Choi WA; Lee JW; Bach JR; Park J; Kang SW
Am J Phys Med Rehabil; 2016 Feb; 95(2):91-5. PubMed ID: 26135371
[TBL] [Abstract][Full Text] [Related]
28. Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep.
Sanders MH; Kern NB; Costantino JP; Stiller RA; Strollo PJ; Studnicki KA; Coates JA; Richards TJ
Chest; 1994 Aug; 106(2):472-83. PubMed ID: 7774323
[TBL] [Abstract][Full Text] [Related]
29. An evaluation of transcutaneous carbon dioxide partial pressure monitoring during apnea testing in brain-dead patients.
Vivien B; Marmion F; Roche S; Devilliers C; Langeron O; Coriat P; Riou B
Anesthesiology; 2006 Apr; 104(4):701-7. PubMed ID: 16571965
[TBL] [Abstract][Full Text] [Related]
30. Transcutaneous CO2 monitoring in adults with sleep-related breathing disorders.
Gislason T; Sandhagen B; Boman G
Ups J Med Sci; 1989; 94(2):171-81. PubMed ID: 2503914
[TBL] [Abstract][Full Text] [Related]
31. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
[TBL] [Abstract][Full Text] [Related]
32. Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation.
Storre JH; Steurer B; Kabitz HJ; Dreher M; Windisch W
Chest; 2007 Dec; 132(6):1810-6. PubMed ID: 18079217
[TBL] [Abstract][Full Text] [Related]
33. Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses.
Umeda A; Ishizaka M; Tasaki M; Yamane T; Watanabe T; Inoue Y; Mochizuki T; Okada Y; Kesler S
BMC Pulm Med; 2020 May; 20(1):151. PubMed ID: 32471394
[TBL] [Abstract][Full Text] [Related]
34. Accuracy of Transcutaneous Carbon Dioxide Measurement During Transcatheter Aortic Valve Replacement Under Monitored Anesthesia Care: A Prospective Observational Study.
Okazawa Y; Kataoka Y; Shindo K
Cureus; 2024 Feb; 16(2):e53661. PubMed ID: 38455779
[TBL] [Abstract][Full Text] [Related]
35. Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques.
May A; Humston C; Rice J; Nemastil CJ; Salvator A; Tobias J
J Anesth; 2020 Feb; 34(1):66-71. PubMed ID: 31701307
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of Arterial to End-tidal Carbon Dioxide Pressure Differences during Laparoscopic Renal Surgery in the Lateral Decubitus Position.
Mahajan S; Chauhan R; Luthra A; Bala I; Bharti N; Sharma A
Anesth Essays Res; 2019; 13(3):583-588. PubMed ID: 31602082
[TBL] [Abstract][Full Text] [Related]
37. Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome.
Hand IL; Shepard EK; Krauss AN; Auld PA
Crit Care Med; 1989 Jun; 17(6):556-9. PubMed ID: 2498038
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of a transcutaneous blood gas monitoring system in critically ill dogs.
Holowaychuk MK; Fujita H; Bersenas AM
J Vet Emerg Crit Care (San Antonio); 2014; 24(5):545-53. PubMed ID: 25186166
[TBL] [Abstract][Full Text] [Related]
39. Transcutaneous O2 and CO2 monitoring of neurosurgical patients: detection of air embolism.
Glenski JA; Cucchiara RF
Anesthesiology; 1986 May; 64(5):546-50. PubMed ID: 3083725
[TBL] [Abstract][Full Text] [Related]
40. Comparison of arterial, end-tidal and transcutaneous PCO2 during moderate exercise and external CO2 loading in humans.
Hoffmann U; Essfeld D; Stegemann J
Eur J Appl Physiol Occup Physiol; 1990; 61(1-2):1-4. PubMed ID: 2127017
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]