These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 3665662)

  • 61. [External compression in osteosynthesis of open diaphyseal fractures of bones of the shin].
    Markova ON
    Voen Med Zh; 1969 Mar; 3():36-9. PubMed ID: 5802806
    [No Abstract]   [Full Text] [Related]  

  • 62. [Significance of the fibula in tibial fractures and pseudarthroses].
    Weise K; Hermichen H; Weller S
    Aktuelle Traumatol; 1985 Oct; 15(5):195-204. PubMed ID: 2866680
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Management of tibial fractures with the orthofix dynamic external fixator.
    Keating JF; Gardner E; Leach WJ; Macpherson S; Abrami G
    J R Coll Surg Edinb; 1991 Aug; 36(4):272-7. PubMed ID: 1941750
    [TBL] [Abstract][Full Text] [Related]  

  • 64. [Analysis of 55 post-traumatic pseudarthroses after tibial fracture].
    Besch L; Bielstein D; Schuckart M; Zenker W
    Zentralbl Chir; 1994; 119(10):702-5. PubMed ID: 7801708
    [TBL] [Abstract][Full Text] [Related]  

  • 65. [Pseudarthrosis of the long bones].
    Thein E; Chevalley F; Borens O
    Rev Med Suisse; 2013 Dec; 9(411):2390-6. PubMed ID: 24693590
    [TBL] [Abstract][Full Text] [Related]  

  • 66. [Stable extraosseous compression osteosynthesis in fractures of the crural bones].
    Kuz'menko VV; Pikin VV; Skorogudaev AV
    Khirurgiia (Mosk); 1992; (7-8):45-8. PubMed ID: 1469871
    [TBL] [Abstract][Full Text] [Related]  

  • 67. A comparison of external fixation alone or combined with intramedullary nailing in the treatment of segmental tibial defects.
    Eralp L; Kocaoğlu M; Polat G; Baş A; Dirican A; Azam ME
    Acta Orthop Belg; 2012 Oct; 78(5):652-9. PubMed ID: 23162962
    [TBL] [Abstract][Full Text] [Related]  

  • 68. [Reconstruction of combined soft tissue and bone defects of the lower leg].
    Hertel P; Hesoun P; Zwank L
    Aktuelle Traumatol; 1982 Dec; 12(6):317-21. PubMed ID: 6130695
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Preliminary report upon a new fixation device for fractures of long bones.
    Dwyer NS
    Injury; 1973 Nov; 5(2):141-4. PubMed ID: 4774766
    [No Abstract]   [Full Text] [Related]  

  • 70. [Effect of geometric pattern and fracture type on the stability of monolateral external fixation].
    Schmargon M; Wilk R; Boenick U; Dreithaler B; Schauwecker HH
    Biomed Tech (Berl); 1988 Mar; 33(3):53-6. PubMed ID: 3370292
    [No Abstract]   [Full Text] [Related]  

  • 71. Compression clamp for use in fractures of the tibia.
    Hamer JD
    Br Med J; 1969 Feb; 1(5642):503. PubMed ID: 5764259
    [No Abstract]   [Full Text] [Related]  

  • 72. Invited Commentary related to: Comparison of 3 Methods for Maintaining Inter-Fragmentary Compression After Fracture Reduction and Fixation.
    Kellam J
    J Orthop Trauma; 2017 Apr; 31(4):213-214. PubMed ID: 28323764
    [No Abstract]   [Full Text] [Related]  

  • 73. A helping hand for the lone surgeon fixing a lateral malleolus fracture.
    O'Leary EJ; Jarvis H; Robinson DW
    Ann R Coll Surg Engl; 2009 Jan; 91(1):81. PubMed ID: 19126339
    [No Abstract]   [Full Text] [Related]  

  • 74. [TREATMENT OF PSEUDOARTHROSIS AND FRACTURES OF THE TUBULAR LONG BONES BY THE COMPRESSION METHOD].
    LANDZHEV B
    Ortop Travmatol Protez; 1965 Feb; 26():10-4. PubMed ID: 14336581
    [No Abstract]   [Full Text] [Related]  

  • 75. Design of an assistant robot for alignment of fractured bones in medical operations.
    Cakiroglu MS; Sancaktar I; Ulutas M; Ertas AH
    Comput Methods Biomech Biomed Engin; 2014; 17 Suppl 1():188-9. PubMed ID: 25074228
    [No Abstract]   [Full Text] [Related]  

  • 76. [A locking type drill protector].
    Niu X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2014 Jan; 38(1):43. PubMed ID: 24839848
    [TBL] [Abstract][Full Text] [Related]  

  • 77. [New clamp for compressive osteosynthesis with built-in dynamometer and plate of original construction].
    Zajić Z
    Vojnosanit Pregl; 1969 Dec; 26(12):632-4. PubMed ID: 5198308
    [No Abstract]   [Full Text] [Related]  

  • 78. [Compression equipment of our construction for external stabilization of fractures of the long bones].
    Kostarczyk A; Kostia W
    Chir Narzadow Ruchu Ortop Pol; 1987; 52(2):149-52. PubMed ID: 3665662
    [No Abstract]   [Full Text] [Related]  

  • 79. [Combination of external fixation unit with a floating suspension splint in the treatment of open lower leg fractures and infected tibial pseudarthrosis].
    Bimler R
    Unfallheilkunde; 1983 Apr; 86(4):196-8. PubMed ID: 6857859
    [No Abstract]   [Full Text] [Related]  

  • 80. [Treatment of patients with ununited fractures and pseudarthrosis of crus bones using G. A. Ilizarov's method].
    Iusupov NT
    Ortop Travmatol Protez; 1991 Jul; (7):44-5. PubMed ID: 1762737
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.