These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 36661910)

  • 1. Removal of Insertable Cardiac Monitor for Cryptogenic Stroke: A Technical Note.
    Egashira S; Kimura N; Doijiri R
    J Cardiovasc Dev Dis; 2023 Jan; 10(1):. PubMed ID: 36661910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable cardiac monitors to detect atrial fibrillation after cryptogenic stroke: a systematic review and economic evaluation.
    Edwards SJ; Wakefield V; Jhita T; Kew K; Cain P; Marceniuk G
    Health Technol Assess; 2020 Jan; 24(5):1-184. PubMed ID: 31944175
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Insertable cardiac monitor extraction technique: hook and reel.
    Ip JE
    J Interv Card Electrophysiol; 2020 Dec; 59(3):481-483. PubMed ID: 32661864
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High Detection Rate of Atrial Fibrillation With Insertable Cardiac Monitor Implantation in Patients With Cryptogenic Stroke Diagnosed by Magnetic Resonance Imaging.
    Iwata T; Todo K; Yamagami H; Morimoto M; Hashimoto T; Doijiri R; Furuya H
    J Stroke Cerebrovasc Dis; 2019 Sep; 28(9):2569-2573. PubMed ID: 31230824
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Insertable cardiac monitors: current indications and devices.
    Sakhi R; Theuns DAMJ; Szili-Torok T; Yap SC
    Expert Rev Med Devices; 2019 Jan; 16(1):45-55. PubMed ID: 30522350
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of insertable cardiac monitors for the detection of atrial fibrillation in patients with cryptogenic stroke in the United States is cost-effective.
    Maervoet J; Bossers N; Borge RP; Hilpert ST; van Engen A; Smala A
    J Med Econ; 2019 Nov; 22(11):1221-1234. PubMed ID: 31480905
    [No Abstract]   [Full Text] [Related]  

  • 7. Cost-effectiveness of insertable cardiac monitors for diagnosis of atrial fibrillation in cryptogenic stroke in Australia.
    Thijs V; Witte KK; Guarnieri C; Makino K; Tilden D; Gillespie J; Huynh M
    J Arrhythm; 2021 Aug; 37(4):1077-1085. PubMed ID: 34386135
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Paroxysmal Atrial Fibrillation in Cryptogenic Stroke Patients With Major-Vessel Occlusion.
    Doijiri R; Yamagami H; Morimoto M; Iwata T; Hashimoto T; Sonoda K; Yamazaki H; Koge J; Kimura N; Todo K
    Front Neurol; 2020; 11():580572. PubMed ID: 33281716
    [No Abstract]   [Full Text] [Related]  

  • 9. [Effectiveness and accuracy of arrhythmia detection algorithm with the Reveal LINQ insertable cardiac monitor].
    Li YH; Tholakanahalli Z; Adabag JM; Wang Z; Li J
    Zhonghua Xin Xue Guan Bing Za Zhi; 2018 Jun; 46(6):470-474. PubMed ID: 29925184
    [No Abstract]   [Full Text] [Related]  

  • 10. Long-term detection of atrial fibrillation with insertable cardiac monitors in a real-world cryptogenic stroke population.
    Ziegler PD; Rogers JD; Ferreira SW; Nichols AJ; Richards M; Koehler JL; Sarkar S
    Int J Cardiol; 2017 Oct; 244():175-179. PubMed ID: 28624331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial.
    Brachmann J; Morillo CA; Sanna T; Di Lazzaro V; Diener HC; Bernstein RA; Rymer M; Ziegler PD; Liu S; Passman RS
    Circ Arrhythm Electrophysiol; 2016 Jan; 9(1):e003333. PubMed ID: 26763225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Insertable cardiac monitors after cryptogenic stroke--a risk factor based approach to enhance the detection rate for paroxysmal atrial fibrillation.
    Poli S; Diedler J; Härtig F; Götz N; Bauer A; Sachse T; Müller K; Müller I; Stimpfle F; Duckheim M; Steeg M; Eick C; Schreieck J; Gawaz M; Ziemann U; Zuern CS
    Eur J Neurol; 2016 Feb; 23(2):375-81. PubMed ID: 26470854
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cost-effectiveness of an insertable cardiac monitor to detect atrial fibrillation in patients with cryptogenic stroke.
    Sawyer LM; Witte KK; Reynolds MR; Mittal S; Grimsey Jones FW; Rosemas SC; Ziegler PD; Kaplon RE; Yaghi S
    J Comp Eff Res; 2021 Feb; 10(2):127-141. PubMed ID: 33300381
    [No Abstract]   [Full Text] [Related]  

  • 14. Will Smartphone Applications Replace the Insertable Cardiac Monitor in the Detection of Atrial Fibrillation? The First Comparison in a Case Report of a Cryptogenic Stroke Patient.
    Wouters F; Gruwez H; Vranken J; Ernon L; Mesotten D; Vandervoort P; Verhaert D
    Front Cardiovasc Med; 2022; 9():839853. PubMed ID: 35402567
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prevalence of atrial fibrillation with insertable cardiac monitors in cryptogenic stroke: A single-center experience.
    Asaithambi G; Monita JE; Annamalai MR; Ho BM; Marino EH; Hanson SK
    J Electrocardiol; 2018; 51(6):973-976. PubMed ID: 30497758
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implantation of a novel insertable cardiac monitor: preliminary multicenter experience in Europe.
    Fareh S; Nardi S; Argenziano L; Diamante A; Scala F; Mandurino C; Magnocavallo M; Poggio L; Scarano M; Gianfrancesco D; Palma F; Silvetti MS; Porcelli D; Racheli M; Montoy M; Charles P; Campari M; Valsecchi S; Lavalle C
    J Interv Card Electrophysiol; 2024 May; ():. PubMed ID: 38755520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MR-imaging pattern is not a predictor of occult atrial fibrillation in patients with cryptogenic stroke.
    Vollmuth C; Stoesser S; Neugebauer H; Hansel A; Dreyhaupt J; Ludolph AC; Kassubek J; Althaus K
    J Neurol; 2019 Dec; 266(12):3058-3064. PubMed ID: 31511980
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frequent Premature Atrial Contractions in Cryptogenic Stroke Predict Atrial Fibrillation Detection with Insertable Cardiac Monitoring.
    Todo K; Iwata T; Doijiri R; Yamagami H; Morimoto M; Hashimoto T; Sonoda K; Yamazaki H; Koge J; Okazaki S; Sasaki T; Mochizuki H
    Cerebrovasc Dis; 2020; 49(2):144-150. PubMed ID: 32023609
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Insertable cardiac monitors for detection of atrial fibrillation after cryptogenic stroke: a meta-analysis.
    Lu Y; Diao SS; Huang SJ; Zhao JJ; Ye MF; Yao FR; Kong Y; Xu Z
    Neurol Sci; 2021 Oct; 42(10):4139-4148. PubMed ID: 33528671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Occult atrial fibrillation in cryptogenic stroke: detection by 7-day electrocardiogram versus implantable cardiac monitors.
    Ritter MA; Kochhäuser S; Duning T; Reinke F; Pott C; Dechering DG; Eckardt L; Ringelstein EB
    Stroke; 2013 May; 44(5):1449-52. PubMed ID: 23449264
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.