These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 36670340)

  • 41. Accuracy of pulse oximetry in children.
    Ross PA; Newth CJ; Khemani RG
    Pediatrics; 2014 Jan; 133(1):22-9. PubMed ID: 24344108
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Accuracy of PaO2 /FiO2 calculated from SpO2 for severity assessment in ED patients with pneumonia.
    Sanz F; Dean N; Dickerson J; Jones B; Knox D; Fernández-Fabrellas E; Chiner E; Briones ML; Cervera Á; Aguar MC; Blanquer J
    Respirology; 2015 Jul; 20(5):813-8. PubMed ID: 25998684
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Emergency Department SpO
    Zhang G; Burla MJ; Caesar BB; Falank CR; Kyros P; Zucco VC; Strumilowska A; Cullinane DC; Sheppard FR
    West J Emerg Med; 2024 May; 25(3):325-331. PubMed ID: 38801037
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The effect of patient ethnicity on the accuracy of peripheral pulse oximetry in patients with COVID-19 pneumonitis: a single-centre, retrospective analysis.
    Wiles MD; El-Nayal A; Elton G; Malaj M; Winterbottom J; Gillies C; Moppett IK; Bauchmuller K
    Anaesthesia; 2022 Feb; 77(2):143-152. PubMed ID: 34542168
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Is pulse oximeter a reliable tool for non-critically ill patients with COVID-19?
    Gürün Kaya A; Öz M; Akdemir Kalkan İ; Gülten E; Çınar G; Azap A; Kaya A
    Int J Clin Pract; 2021 Dec; 75(12):e14983. PubMed ID: 34637170
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Validation of the Withings ScanWatch as a Wrist-Worn Reflective Pulse Oximeter: Prospective Interventional Clinical Study.
    Kirszenblat R; Edouard P
    J Med Internet Res; 2021 Apr; 23(4):e27503. PubMed ID: 33857011
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
    Giguère S; Sanchez LC; Shih A
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients.
    Blanchet MA; Mercier G; Delobel A; Nayet E; Bouchard PA; Simard S; L'Her E; Branson RD; Lellouche F
    Respir Care; 2023 May; 68(5):565-574. PubMed ID: 36596654
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Impact of ethnicity on the accuracy of measurements of oxygen saturations: A retrospective observational cohort study.
    Bangash MN; Hodson J; Evison F; Patel JM; Johnston AM; Gallier S; Sapey E; Parekh D
    EClinicalMedicine; 2022 Jun; 48():101428. PubMed ID: 35706489
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Arterial Oxygen Saturation: A Vital Sign?
    Singhal A; Prafull K; Daulatabad VS; John NA; John J
    Niger J Clin Pract; 2023 Nov; 26(11):1591-1594. PubMed ID: 38044759
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?
    Perkins GD; McAuley DF; Giles S; Routledge H; Gao F
    Crit Care; 2003 Aug; 7(4):R67. PubMed ID: 12930558
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Accuracy of a pulse oximeter during hypoxia].
    Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y
    Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions.
    Benoit H; Costes F; Feasson L; Lacour JR; Roche F; Denis C; Geyssant A; Barthélémy JC
    Eur J Appl Physiol Occup Physiol; 1997; 76(3):260-3. PubMed ID: 9286606
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Improving the sampling technique of arterialized capillary samples to obtain more accurate PaO2 measurements.
    Wimpress S; Vara DD; Brightling CE
    Chron Respir Dis; 2005; 2(1):47-50. PubMed ID: 16279749
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Assessment of the SpO
    Catoire P; Tellier E; de la Rivière C; Beauvieux MC; Valdenaire G; Galinski M; Revel P; Combes X; Gil-Jardiné C
    Am J Emerg Med; 2021 Jun; 44():116-120. PubMed ID: 33588251
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Hypoxemia During Extreme Hyperleukocytosis: How Spurious?
    Van de Louw A; Desai RJ; Schneider CW; Claxton DF
    Respir Care; 2016 Jan; 61(1):8-14. PubMed ID: 26420901
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Pulse Oximetry and Race in Critically Ill Adults.
    Seitz KP; Wang L; Casey JD; Markus SA; Jackson KE; Qian ET; Self WH; Rice TW; Semler MW
    Crit Care Explor; 2022 Sep; 4(9):e0758. PubMed ID: 36128001
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Evaluation of PaO2 /FiO2 and SaO2 /FiO2 ratios in postoperative dogs recovering on room air or nasal oxygen insufflation.
    Carver A; Bragg R; Sullivan L
    J Vet Emerg Crit Care (San Antonio); 2016 May; 26(3):437-45. PubMed ID: 27082519
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Racial effects on Masimo pulse oximetry: a laboratory study.
    Barker SJ; Wilson WC
    J Clin Monit Comput; 2023 Apr; 37(2):567-574. PubMed ID: 36370242
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.
    Seifi S; Khatony A; Moradi G; Abdi A; Najafi F
    BMC Nurs; 2018; 17():15. PubMed ID: 29692684
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.