These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
207 related articles for article (PubMed ID: 36696695)
21. Performance of a deep learning-based CT image denoising method: Generalizability over dose, reconstruction kernel, and slice thickness. Zeng R; Lin CY; Li Q; Jiang L; Skopec M; Fessler JA; Myers KJ Med Phys; 2022 Feb; 49(2):836-853. PubMed ID: 34954845 [TBL] [Abstract][Full Text] [Related]
22. Generalized conditional gradient method with adaptive regularization parameters for fluorescence molecular tomography. Chen Y; Du M; Zhang J; Zhang G; Su L; Li K; Zhao F; Yi H; Wang L; Cao X Opt Express; 2023 May; 31(11):18128-18146. PubMed ID: 37381530 [TBL] [Abstract][Full Text] [Related]
23. Recovery of missing data in partial geometry PET scanners: Compensation in projection space vs image space. Shojaeilangari S; Schmidtlein CR; Rahmim A; Ay MR Med Phys; 2018 Dec; 45(12):5437-5449. PubMed ID: 30288762 [TBL] [Abstract][Full Text] [Related]
24. Total variation regularization for 3D reconstruction in fluorescence tomography: experimental phantom studies. Behrooz A; Zhou HM; Eftekhar AA; Adibi A Appl Opt; 2012 Dec; 51(34):8216-27. PubMed ID: 23207394 [TBL] [Abstract][Full Text] [Related]
25. Reconstruction Method for Optical Tomography Based on the Linearized Bregman Iteration with Sparse Regularization. Leng C; Yu D; Zhang S; An Y; Hu Y Comput Math Methods Med; 2015; 2015():304191. PubMed ID: 26421055 [TBL] [Abstract][Full Text] [Related]
26. Nonconvex Laplacian Manifold Joint Method for Morphological Reconstruction of Fluorescence Molecular Tomography. He X; Meng H; He X; Wang K; Song X; Tian J Mol Imaging Biol; 2021 Jun; 23(3):394-406. PubMed ID: 33415678 [TBL] [Abstract][Full Text] [Related]
27. Reduced iteration image reconstruction of incomplete projection CT using regularization strategy through Lp norm dictionary learning. Gou J; Wu X; Dong H J Xray Sci Technol; 2019; 27(3):559-572. PubMed ID: 31177257 [TBL] [Abstract][Full Text] [Related]
28. CT artifact correction for sparse and truncated projection data using generative adversarial networks. Podgorsak AR; Shiraz Bhurwani MM; Ionita CN Med Phys; 2021 Feb; 48(2):615-626. PubMed ID: 32996149 [TBL] [Abstract][Full Text] [Related]
30. Improving diffuse optical tomography imaging quality using APU-Net: an attention-based physical U-Net model. Xue M; Li S; Zhu Q J Biomed Opt; 2024 Aug; 29(8):086001. PubMed ID: 39070721 [TBL] [Abstract][Full Text] [Related]
31. Limited parameter denoising for low-dose X-ray computed tomography using deep reinforcement learning. Patwari M; Gutjahr R; Raupach R; Maier A Med Phys; 2022 Jul; 49(7):4540-4553. PubMed ID: 35362172 [TBL] [Abstract][Full Text] [Related]
32. Back-propagation neural network-based reconstruction algorithm for diffuse optical tomography. Feng J; Sun Q; Li Z; Sun Z; Jia K J Biomed Opt; 2018 Dec; 24(5):1-12. PubMed ID: 30569669 [TBL] [Abstract][Full Text] [Related]
33. An adaptive Tikhonov regularization method for fluorescence molecular tomography. Cao X; Zhang B; Wang X; Liu F; Liu K; Luo J; Bai J Med Biol Eng Comput; 2013 Aug; 51(8):849-58. PubMed ID: 23504309 [TBL] [Abstract][Full Text] [Related]
34. Elastic net-based non-negative iterative three-operator splitting strategy for Cerenkov luminescence tomography. Chen Y; Li W; Du M; Su L; Yi H; Zhao F; Li K; Wang L; Cao X Opt Express; 2022 Sep; 30(20):35282-35299. PubMed ID: 36258483 [TBL] [Abstract][Full Text] [Related]
35. Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery. Hashemi S; Song WY; Sahgal A; Lee Y; Huynh C; Grouza V; Nordström H; Eriksson M; Dorenlot A; Régis JM; Mainprize JG; Ruschin M Phys Med Biol; 2017 Apr; 62(7):2521-2541. PubMed ID: 28248652 [TBL] [Abstract][Full Text] [Related]
36. Adaptive row-action inverse solver for fast noise-robust three-dimensional reconstructions in bioluminescence tomography: theory and dual-modality optical/computed tomography in vivo studies. Behrooz A; Kuo C; Xu H; Rice B J Biomed Opt; 2013 Jul; 18(7):76010. PubMed ID: 23843087 [TBL] [Abstract][Full Text] [Related]
37. A robust elastic net- Zhao J; Guo H; Yu J; Yi H; Hou Y; He X Phys Med Biol; 2021 Sep; 66(19):. PubMed ID: 34492648 [No Abstract] [Full Text] [Related]
38. High-fidelity fast volumetric brain MRI using synergistic wave-controlled aliasing in parallel imaging and a hybrid denoising generative adversarial network (HDnGAN). Li Z; Tian Q; Ngamsombat C; Cartmell S; Conklin J; Filho ALMG; Lo WC; Wang G; Ying K; Setsompop K; Fan Q; Bilgic B; Cauley S; Huang SY Med Phys; 2022 Feb; 49(2):1000-1014. PubMed ID: 34961944 [TBL] [Abstract][Full Text] [Related]
39. Self-guided reconstruction for time-domain fluorescence molecular lifetime tomography. Cai C; Cai W; Cheng J; Yang Y; Luo J J Biomed Opt; 2016 Dec; 21(12):126012. PubMed ID: 27999862 [TBL] [Abstract][Full Text] [Related]
40. Reconstruction algorithms based on l1-norm and l2-norm for two imaging models of fluorescence molecular tomography: a comparative study. Yi H; Chen D; Li W; Zhu S; Wang X; Liang J; Tian J J Biomed Opt; 2013 May; 18(5):56013. PubMed ID: 23722452 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]